A COMPARISON OF 3 COMMERCIALLY AVAILABLE PET IMAGING-SYSTEMS

被引:10
|
作者
BATCHELOR, S
BLAKE, GM
SAUNDERS, JE
机构
[1] Department of Medical Physics, St Thomas' Hospital
[2] Department of Nuclear Medicine, Guy's Hospital
关键词
D O I
10.1097/00006231-199201000-00004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Three commercial positron emission tomography (PET) imagers were assessed using the same test protocol (Positron Corporation 'Posicam', Siemens Ecat 951/31 and the Scanditronix PC 4096-15WB). A cylindrical phantom and a 'Jaszczak' phantom both filled with F-18 were employed to measure sensitivity, slice uniformity, transaxial and axial resolution and cold rod contrast. The spread of results were as follows: sensitivity varied from 2.08 to 3.73 kcps kBq-1 ml-1 (77-138 kcps mu-Ci-1 ml-1); radial resolution on axis (at 17.5 cm) varied from 5.0 to 5.9 mm (6.7-8.1 mm); tangential resolution ranged from 5.4 to 5.8 mm (6.7-8.6 mm); axial resolution ranged from 4.6 to 11.5 mm (6.6-13.6 mm); contrast in the middle of a 30 mm diameter rod varied from 98 to 93% and for a 5 mm rod from 37 to 22%. The performance of all three systems approximated reasonably well to the manufacturers' published specifications. The most significant differences were found to be in sensitivity, axial resolution and deadtime correction and can be explained by the choice of crystal size and crystal/photomultiplier configuration.
引用
收藏
页码:20 / 27
页数:8
相关论文
共 50 条
  • [1] Small animal PET: A review of commercially available imaging systems
    Larobina, M
    Brunetti, A
    Salvatore, M
    [J]. CURRENT MEDICAL IMAGING REVIEWS, 2006, 2 (02) : 187 - 192
  • [2] COMPARISON OF 3 3-DIMENSIONAL IMAGING-SYSTEMS
    JONES, PF
    AITKEN, GTM
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1994, 11 (10): : 2613 - 2621
  • [3] Performance Comparison of An In-House and a Commercially Available Amplitude Gating Device for PET Imaging
    Chang, G.
    Chang, T.
    Jackson, J.
    Clark, J.
    Mawlawi, O.
    [J]. MEDICAL PHYSICS, 2009, 36 (06) : 2469 - +
  • [4] Performance comparison of three commercially available PET systems: SIGNA PET/MR, Discovery IQ and Discovery MI
    Ilan, Ezgi
    Deller, Timothy
    Kjellberg, Fredric
    Peterson, William
    Lubberink, Mark
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [5] A COMPARISON OF 4 INTRAVASCULAR ULTRASOUND IMAGING-SYSTEMS
    HIRO, T
    LEUNG, CY
    RUSSO, RJ
    GUTFINGER, DE
    FARVID, AR
    KARIMI, H
    TOBIS, JM
    [J]. CIRCULATION, 1994, 90 (04) : 551 - 551
  • [6] COMPARISON OF 3 COMMERCIALLY AVAILABLE GC-FPD SYSTEMS IN THE SULFUR MODE
    MCGAUGHEY, JF
    GANGWAL, SK
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1979, (SEP): : 3 - &
  • [7] Comparison of two commercially available cryoballoon ablation systems
    Diofano, F.
    Pflieger, C.
    Teumer, Y.
    Bothner, C.
    Rottbauer, W.
    Dahme, T.
    Weinmann, K.
    [J]. EUROPEAN HEART JOURNAL, 2023, 44
  • [8] The measurement of human motion: A comparison of commercially available systems
    Richards, JG
    [J]. HUMAN MOVEMENT SCIENCE, 1999, 18 (05) : 589 - 602
  • [9] IMAGE COMPARISON TECHNIQUES FOR USE WITH MEGAVOLTAGE IMAGING-SYSTEMS
    EVANS, PM
    GILDERSLEVE, JQ
    MORTON, EJ
    SWINDELL, W
    COLES, R
    FERRARO, M
    RAWLINGS, C
    XIAO, ZR
    DYER, J
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (776): : 701 - 709
  • [10] AN ROC COMPARISON OF 2 COMPUTERIZED TMJ IMAGING-SYSTEMS
    TYNDALL, D
    DAVIES, K
    LUDLOW, J
    DOVE, JB
    [J]. JOURNAL OF DENTAL RESEARCH, 1995, 74 : 19 - 19