AMPEROMETRIC DETERMINATION OF CHOLINE AND ACETYLCHOLINE WITH ENZYMES IMMOBILIZED IN A PHOTOCROSS-LINKABLE POLYMER

被引:36
|
作者
MARTY, JL
SODE, K
KARUBE, I
机构
[1] UNIV TOKYO,ADV SCI & TECHNOL RES CTR,4-6-1 KOMADA,MEGURO KU,TOKYO 153,JAPAN
[2] TOKYO INST TECHNOL,RESOURCES UTILIZAT RES LAB,YOKOHAMA,KANAGAWA 227,JAPAN
关键词
D O I
10.1016/S0003-2670(00)80477-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Choline and acetylcholine sensors were prepared by using choline oxidase and acetylcholinesterase, entrapped in photocross- linkable poly(vinyl alcohol) bearing styrylpyridinium (PVA-SbQ). The measurements were based on the detection of hydrogen peroxide liberated by an enzyme reaction (choline oxidase) or two sequential enzyme reactions (acetylcholine esterase and choline oxidase). The determination range for choline was 2.5-2-150 αmol 1-1 and for acetylcholine 20-2-750 αmol 1-1. The response times were 2-2-4 min. The immobilized enzyme membranes stored in a dry state were very stable and no loss of activity was observed after storage for 60 days. © 1990.
引用
收藏
页码:49 / 53
页数:5
相关论文
共 39 条
  • [1] AMPEROMETRIC ACETYLCHOLINE AND CHOLINE SENSORS WITH IMMOBILIZED ENZYMES
    MASCINI, M
    MOSCONE, D
    ANALYTICA CHIMICA ACTA, 1986, 179 : 439 - 444
  • [2] Direct observation of localized conduction pathways in photocross-linkable polymer memory
    Kwan, Wei Lek
    Lei, Bao
    Shao, Yue
    Prikhodko, Sergey V.
    Bodzin, Noah
    Yang, Yang
    JOURNAL OF APPLIED PHYSICS, 2009, 105 (12)
  • [3] Anisotropic photonic gratings formed in photocross-linkable polymer liquid crystals
    Ono, Hiroshi
    Emoto, Akira
    Kawatsuki, Nobuhiro
    JOURNAL OF APPLIED PHYSICS, 2006, 100 (01)
  • [4] AMPEROMETRIC BIOSENSORS FOR THE DETERMINATION OF CHOLINE AND ACETYLCHOLINE
    LOFFLER, U
    WOLLENBERGER, U
    SCHELLER, F
    GOPEL, W
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 335 (03): : 295 - 298
  • [5] AMPEROMETRIC DETERMINATION OF CHOLINE WITH USE OF IMMOBILIZED CHOLINE OXIDASE
    MATSUMOTO, K
    SEIJO, H
    KARUBE, I
    SUZUKI, S
    BIOTECHNOLOGY AND BIOENGINEERING, 1980, 22 (05) : 1071 - 1086
  • [6] Amperometric biosensor based on enzymes immobilized in hybrid mesoporous membranes for the determination of acetylcholine
    Shimomura, Takeshi
    Itoh, Tetsuji
    Sumiya, Touru
    Mizukami, Fujio
    Ono, Masatoshi
    ENZYME AND MICROBIAL TECHNOLOGY, 2009, 45 (6-7) : 443 - 448
  • [7] DETERMINATION OF ACETYLCHOLINE AND CHOLINE BY FLOW-INJECTION WITH IMMOBILIZED ENZYMES AND FLUOROMETRIC OR LUMINOMETRIC DETECTION
    RICNY, J
    COUPEK, J
    TUCEK, S
    ANALYTICAL BIOCHEMISTRY, 1989, 176 (02) : 221 - 227
  • [8] Determination of acetylcholine and choline in rat brain tissue by FIA with immobilized enzymes and chemiluminescence detection
    Fan, WZ
    Zhang, ZJ
    MICROCHEMICAL JOURNAL, 1996, 53 (03) : 290 - 295
  • [9] Large birefringence and polarization holographic gratings formed in photocross-linkable polymer liquid crystals comprising bistolane mesogenic side groups
    Emoto, Akira
    Matsumoto, Taro
    Yamashita, Ayumi
    Shioda, Tatsutoshi
    Ono, Hiroshi
    Kawatsuki, Nobuhiro
    JOURNAL OF APPLIED PHYSICS, 2009, 106 (07)