RADIATION-DAMAGE BY NEUTRONS TO PLASTIC SCINTILLATORS

被引:4
|
作者
BUSS, G
DANNEMANN, A
WICK, UHK
机构
[1] Institut für Experimentalphysik, Universität Hamburg, D-22761 Hamburg
关键词
D O I
10.1109/23.467829
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Polystyrene based scintillator SCSN38, wavelength shifter Y7 with polymethylmethacrylate matrix and pure PMMA light guide GS218 have been irradiated in the mixed radiation field of a pool reactor. About 77% of the dose released in SCSN38 was caused by the gamma-field, 23% by fast neutrons. The total dose ranged from 2 to 105 kGy. The dose measurements were made using alanine dosimeters. Transmission and fluorescence of the samples have been measured before and several times after irradiation. The radiation damage results show no differences to irradiations in pure gamma-fields with corresponding released doses.
引用
下载
收藏
页码:315 / 319
页数:5
相关论文
共 50 条
  • [1] RADIATION-DAMAGE OF PLASTIC SCINTILLATORS
    BROSS, AD
    PLADALMAU, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (05) : 1199 - 1204
  • [2] RADIATION-DAMAGE OF PLASTIC SCINTILLATORS AND OPTIC FIBERS
    VASILCHENKO, VG
    PROTOPOPOV, YM
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1994, 37 (01) : 53 - 58
  • [3] A PEDESTRIANS GUIDE TO RADIATION-DAMAGE IN PLASTIC SCINTILLATORS
    ZORN, C
    NUCLEAR PHYSICS B, 1993, : 377 - 383
  • [4] A PEDESTRIANS GUIDE TO RADIATION-DAMAGE IN PLASTIC SCINTILLATORS
    ZORN, C
    RADIATION PHYSICS AND CHEMISTRY, 1993, 41 (1-2): : 37 - 43
  • [5] RADIATION-DAMAGE IN PLASTIC SCINTILLATORS AND OPTICAL FIBERS
    PROTOPOPOV, YM
    VASILCHENKO, VG
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1995, 95 (04): : 496 - 500
  • [6] RADIATION-DAMAGE MEASUREMENTS ON PVT-BASED PLASTIC SCINTILLATORS
    ILIE, S
    SCHONBACHER, H
    TAVLET, M
    NUCLEAR PHYSICS B, 1993, : 384 - 391
  • [7] RADIATION-DAMAGE BY MONOENERGETIC NEUTRONS
    GOLDSTONE, JA
    PARKIN, DM
    SIMPSON, HM
    SMITH, RK
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1977, 22 (03): : 330 - 330
  • [8] RECOVERY AND PERMANENT RADIATION-DAMAGE OF PLASTIC SCINTILLATORS AT DIFFERENT DOSE-RATES
    BICKEN, B
    HOLM, U
    MARCKMANN, T
    WICK, K
    ROHDE, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (02) : 188 - 193
  • [9] RADIATION-DAMAGE STUDIES IN PLASTIC SCINTILLATORS WITH A 2.5-MEV ELECTRON-BEAM
    MAJEWSKI, S
    BOWEN, M
    ZORN, C
    JOHNSON, K
    HAGOPIAN, V
    THOMASTON, J
    WAHL, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 281 (03): : 500 - 507
  • [10] EFFECT OF RADIATION DAMAGE ON PLASTIC SCINTILLATORS
    OLDHAM, G
    WARE, AR
    BLACKWEL.SA