MEMBRANE FLUIDITY MEASURED BY FLUORESCENCE POLARIZATION USING AN EPICS V-CELL SORTER

被引:42
|
作者
FOX, MH
DELOHERY, TM
机构
[1] COLORADO STATE UNIV, DEPT RADIOL & RADIAT BIOL, FT COLLINS, CO 80523 USA
[2] COLUMBIA UNIV, CELL SORTER LAB, NEW YORK, NY 10027 USA
来源
CYTOMETRY | 1987年 / 8卷 / 01期
关键词
D O I
10.1002/cyto.990080104
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We have characterized the measurement of fluorescence polarization on single cells using an EPICS V cell sorter. A critical analysis is made of the balancing and calibration of the system. The system is highly linear for polarization measurements. Cellular membranes were labeled with 1,6-diphenyl-1,3,5-hexatriene (DPH) to measure membrane fluidity. Fluorescence polarization histograms had coefficients of variation as low as 7%. Cells labeled with DPH after 24 hr incubation in medium lacking serum showed a significantly higher fluorescence polarization than cells in medium containing serum. The fluorescence polarization measured at 15.degree. C was 0.311 compared to 0.270 at 25.degree. C for cells labeled with DPH, verifying that temperature affects the membrane fluidity as measured by flow cytometry.
引用
收藏
页码:20 / 25
页数:6
相关论文
共 50 条
  • [1] ANALYSIS OF B-CELL SUBPOPULATIONS IN CHRONIC LYMPHOCYTIC-LEUKEMIA USING MONOCLONAL-ANTIBODIES AND THE EPICS V-CELL SORTER
    MURPHY, J
    MILLARD, RE
    BRITISH JOURNAL OF HAEMATOLOGY, 1986, 64 (04) : 822 - 822
  • [2] MEMBRANE FLUIDITY AND FLUORESCENCE POLARIZATION
    CARBONNEAU, MA
    MONTAUDON, D
    ROBERT, J
    ANNALES DE BIOLOGIE CLINIQUE, 1988, 46 (01) : 93 - 93
  • [3] ALTERATIONS IN MEMBRANE FLUIDITY DURING KERATINOCYTE DIFFERENTIATION MEASURED BY FLUORESCENCE POLARIZATION
    HACHISUKA, H
    NOMURA, H
    MORI, O
    NAKANO, S
    OKUBO, K
    KUSUHARA, M
    KARASHIMA, M
    TANIKAWA, E
    HIGUCHI, M
    SASAI, Y
    CELL AND TISSUE RESEARCH, 1990, 260 (01) : 207 - 210
  • [4] EXPERIMENTAL APPROACHES OF CELL-MEMBRANE FLUIDITY BY FLUORESCENCE POLARIZATION
    DONNER, M
    STOLTZ, JF
    CLINICAL HEMORHEOLOGY, 1985, 5 (05): : 588 - 588
  • [5] Cell membrane fluidity determined by fluorescence lifetime and polarization screening
    Bruns, Thomas
    Strauss, Wolfgang S. L.
    Schneckenburger, Herbert
    ADVANCES IN MEDICAL ENGINEERING, 2007, 114 : 366 - +
  • [6] FLUORESCENCE POLARIZATION OF 6 MEMBRANE PROBES IN EMBRYONAL CARCINOMA-CELLS AFTER DIFFERENTIATION AS MEASURED ON A FACS-II CELL SORTER
    SCHAAP, GH
    DEJONG, JED
    JONGKIND, JF
    CYTOMETRY, 1984, 5 (02): : 188 - 193
  • [7] Fluorescence polarization used to derive cell membrane fluidity during photodynamic therapy
    Wei, RH
    Huang, YP
    Li, SS
    Qi, CY
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25 (11) : 1827 - 1829
  • [8] CHANGE OF INTRACELLULAR FLUIDITY DURING KERATINOCYTE DIFFERENTIATION MEASURED BY FLUORESCENCE POLARIZATION
    HACHISUKA, H
    NOMURA, H
    SASAI, Y
    SHIOTSUKI, K
    YOKOYAMA, MM
    CELL AND TISSUE RESEARCH, 1986, 246 (03) : 557 - 560
  • [9] MEASUREMENT OF STRATUM-CORNEUM MEMBRANE FLUIDITY BY FLUORESCENCE POLARIZATION
    PELLE, E
    STUBBS, C
    PENNA, F
    SMITH, WP
    CLINICAL RESEARCH, 1987, 35 (03): : A709 - A709
  • [10] MEMBRANE FLUIDITY OF TOXOPLASMA-GONDII - A FLUORESCENCE POLARIZATION STUDY
    GALLOIS, Y
    FOUSSARD, F
    GIRAULT, A
    HODBERT, J
    TRICAUD, A
    MAURAS, G
    MOTTA, C
    BIOLOGY OF THE CELL, 1988, 62 (01) : 11 - 15