Simulation of PEMFC Stack for Portable Power Generator Application

被引:7
|
作者
Abd Rahman, Siti Najibah [1 ]
Masdar, Mohd Shahbudin [1 ,2 ]
Rosli, Masli Irwan [1 ,2 ]
Majlan, Edy Herianto [1 ]
Rejab, Syahril Anuar Md [1 ,3 ]
Lye, Chew Chien [3 ]
机构
[1] Univ Kebangsaan Malaysia, Fuel Cell Inst, Bangi, Malaysia
[2] Univ Kebangsaan Malaysia, Res Ctr Sustainable Proc Technol CESPRO, Fac Engn & Built Environm, Programme Chem Engn, Bangi, Malaysia
[3] Sime Darby Res Sdn Bhd, Pulau Carey, Selangor, Malaysia
来源
JURNAL KEJURUTERAAN | 2018年 / 1卷 / 01期
关键词
Polymer Electrolyte Membrane Fuel Cell; Simulink; Stoichiometry; Relative Humidity;
D O I
10.17576/jkukm-2018-si1(1)-01
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Generally, it is possible to reduce the size, cost, and parasitic loss of polymer electrolyte membrane fuel cell (PEMFC) system with an air-cooled system, open cathode and self-humidifying stack for portable fuel cell application. In order to ensure the that PEMFC stack applicable for portable fuel cell application, a mathematical model is useful tool for saving design cost, giving a better system design and operation. Therefore, this study is focused on developing a simplified zero-dimensional mathematical model for self-humidifying and open cathode 200W PEMFC stack for portable fuel cell generator application. The mathematical equations are modelled by using Matlab-Simulink tools in order to simulate the operation of the developed mode. This simulation is then compared to a commercially 200W Horizon PEMFC stack (H-200) for data validation purposes. The air inlet flow rate is chosen to test the sensitivity of the fuel cell stack model. The air inlet stoichiometry of 2, 5, 20, and 50 was varied to generate a different air inlet flow rate. Based on the simulation, air inlet stoichiometry above 15 is sufficient to produce a high output stack voltage. However, in a real operation of the H-200 fuel cell stack system needs air inlet stoichiometry at about 20 because a fan is used to supply air and also the cooling system. High anode and cathode relative humidity result in a high output stack voltage. However, it is better to increase the anode relative humidity than cathode relative humidity to get high output stack voltage.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
  • [1] Experimental and numerical studies of portable PEMFC stack
    Shimpalee, S.
    Ohashi, M.
    Van Zee, J. W.
    Ziegler, C.
    Stoeckmann, C.
    Sadeler, C.
    Hebling, C.
    [J]. ELECTROCHIMICA ACTA, 2009, 54 (10) : 2899 - 2911
  • [2] Numerical simulation of a mini PEMFC stack
    Liu, Zhixiang
    Mao, Zongqiang
    Wang, Cheng
    Zhuge, Weilin
    Zhang, Yangjun
    [J]. JOURNAL OF POWER SOURCES, 2006, 160 (02) : 1111 - 1121
  • [3] Modeling and simulation of PEMFC stack dynamic performance
    Jiao, Jieran
    Chen, Fengxiang
    Yu, Yang
    He, Jilong
    Chen, Xiaoyu
    [J]. 2017 CHINESE AUTOMATION CONGRESS (CAC), 2017, : 2871 - 2876
  • [4] Simulation and Optimization of Air-Cooled PEMFC Stack for Lightweight Hybrid Vehicle Application
    Liang, Jingming
    Wu, Zefeng
    [J]. MATHEMATICAL PROBLEMS IN ENGINEERING, 2015, 2015
  • [5] Sensitivity analysis of stack power uncertainty in a PEMFC-based powertrain for aircraft application
    Correa, G.
    Borello, F.
    Santarelli, M.
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2015, 40 (32) : 10354 - 10365
  • [6] Mathematical Modeling Of PEMFC Stack For Real Time Simulation
    Breaz, Elena
    Tirnovan, Radu
    Gao, Fei
    Blunier, Benjamin
    Miraoui, Abdellatif
    [J]. 2012 IEEE INTERNATIONAL CONFERENCE ON AUTOMATION, QUALITY AND TESTING, ROBOTICS, THETA 18TH EDITION, 2012, : 553 - 558
  • [7] Electron Transport Modeling for a Portable PEMFC Stack Using Star-CD
    Ippolito, J.
    Shimpalee, S.
    [J]. FUEL CELL SEMINAR 2010, 2011, 30 (01): : 195 - 205
  • [8] Development of cost innovative BPs for a PEMFC stack for a 1 kW-class residential power generator (RPG) system
    Lee, Gil-yong
    Jung, Min-kyung
    Ryoo, Sun-nam
    Park, Myung-seok
    Ha, Sam-chul
    Kim, Sunhoe
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2010, 35 (23) : 13131 - 13136
  • [9] Implementation of portable mini wind power generator as renewable energy simulation media
    Achmad, F.
    Muslim, S.
    [J]. 5TH ANNUAL APPLIED SCIENCE AND ENGINEERING CONFERENCE (AASEC 2020), 2021, 1098
  • [10] Thermal management of portable PEMFC power supply system
    Wang, JL
    Shen, WD
    Ruan, Y
    Du, ML
    [J]. PROCEEDINGS OF THE 3RD INTERNATIONAL SYMPOSIUM ON HEAT TRANSFER ENHANCEMENT AND ENERGY CONSERVATION, VOLS 1 AND 2, 2004, : 1505 - 1511