RECOVERY OF DIAPHYSEAL BONE STRENGTH AFTER RIGID INTERNAL PLATE FIXATION - AN EXPERIMENTAL-STUDY IN THE RABBIT

被引:36
|
作者
LAFTMAN, P
SIGURDSSON, F
STROMBERG, L
机构
[1] KAROLINSKA HOSP,DEPT GEN SURG,S-10401 STOCKHOLM,SWEDEN
[2] KAROLINSKA HOSP,DEPT ORTHOPAED SURG,S-10401 STOCKHOLM,SWEDEN
[3] KAROLINSKA HOSP,DEPT EXPTL SURG,S-10401 STOCKHOLM,SWEDEN
来源
ACTA ORTHOPAEDICA SCANDINAVICA | 1980年 / 51卷 / 02期
关键词
D O I
10.3109/17453678008990789
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
引用
收藏
页码:215 / 222
页数:8
相关论文
共 50 条
  • [1] RECOVERY OF DIAPHYSEAL BONE STRENGTH AFTER RIGID INTERNAL PLATE FIXATION
    JOUKAINEN, J
    PAAVOLAINEN, P
    SLATIS, P
    HOLMSTROM, T
    ACTA ORTHOPAEDICA SCANDINAVICA, 1983, 54 (03): : 512 - 512
  • [2] DIAPHYSEAL BONE STRENGTH ADAPTATION TO RIGID INTERNAL PLATE FIXATION - EXPERIMENTAL-STUDY ON RABBITS
    SIGURDSSON, F
    LAFTMAN, P
    STROMBERG, L
    ACTA ORTHOPAEDICA SCANDINAVICA, 1979, 50 (01): : 115 - 115
  • [3] TORSIONAL STRENGTH AND GEOMETRY OF DIAPHYSEAL BONE - EXPERIMENTAL-STUDY ON DOGS
    NETZ, P
    ERIKSSON, K
    STROMBERG, L
    ACTA ORTHOPAEDICA SCANDINAVICA, 1978, 49 (05): : 430 - 434
  • [4] BIOMECHANICAL STRENGTH OF NONVASCULARIZED AND VASCULARIZED DIAPHYSEAL BONE TRANSPLANTS - AN EXPERIMENTAL-STUDY
    NATHER, A
    GOH, JCH
    LEE, JJ
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (06): : 1031 - 1035
  • [5] ATROPHY OF CORTICAL BONE CAUSED BY RIGID INTERNAL-FIXATION PLATES - EXPERIMENTAL-STUDY IN DOG
    STROMBERG, L
    DALEN, N
    ACTA ORTHOPAEDICA SCANDINAVICA, 1978, 49 (05): : 448 - 456
  • [6] AN EXPERIMENTAL-STUDY IN THE RABBIT OF THE ROLE OF CORTICOCANCELLOUS BONE-GRAFT TO AUGMENT PLATE FIXATION OF A CONTAMINATED OSTEOTOMY
    CLEMENT, DA
    SZYPRYT, EP
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (03): : 496 - 496
  • [7] DOES THE POROSITY INDUCED IN RABBIT TUBULAR BONE BY RIGID PLATE FIXATION DISAPPEAR AFTER PLATE REMOVAL - A PLANIMETRIC STUDY
    HOLMSTROM, T
    JOUKAINEN, J
    SLATIS, P
    ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (06): : 707 - 707
  • [8] THE EFFECT OF RIGID FIXATION ON THE SURVIVAL OF ONLAY BONE-GRAFTS - AN EXPERIMENTAL-STUDY
    LIN, KY
    BARTLETT, SP
    YAREMCHUK, MJ
    FALLON, M
    GROSSMAN, RF
    WHITAKER, LA
    PLASTIC AND RECONSTRUCTIVE SURGERY, 1990, 86 (03) : 449 - 456
  • [9] HEALING OF NONVASCULARIZED DIAPHYSEAL BONE TRANSPLANTS - AN EXPERIMENTAL-STUDY
    NATHER, A
    BALASUBRAMANIAM, P
    BOSE, K
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (05): : 830 - 834
  • [10] TORSIONAL STRENGTH OF CORTICAL AND CANCELLOUS BONE-GRAFTS AFTER RIGID PLATE FIXATION
    WARIS, P
    ACTA ORTHOPAEDICA SCANDINAVICA, 1980, 51 (04): : 703 - 703