MICROELECTRODE ARRAYS AND APPLICATION TO BIOSENSING DEVICES

被引:78
|
作者
HINTSCHE, R
PAESCHKE, M
WOLLENBERGER, U
SCHNAKENBERG, U
WAGNER, B
LISEC, T
机构
[1] Fraunhofer-Institut für Siliziumtechnologie, D-14199 Berlin
来源
BIOSENSORS & BIOELECTRONICS | 1994年 / 9卷 / 9-10期
关键词
SI-TECHNOLOGY; BIOSENSOR; MICROELECTRODE ARRAY; MICROMACHINING; AMPEROMETRIC MEASUREMENT; MULTIPOTENIOSTAT; REDOX RECYCLING;
D O I
10.1016/0956-5663(94)80068-5
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An electrochemical microanalytical system consisting of a microelectrode array, a micromachined flow-through assembly, and a multichannel potentiostat were constructed for highly sensitive biosensing. Thin-film platinum microelectrode arrays consisting of four interdigitated microelectrodes (IDAs), which are spaced in the sub-micrometer range, were fabricated using silicon technology. On top of this chip, a micromachined flow-through cell was mounted. Using a home made miniaturized multipotentiostat, amperometric measurements of the individual electrodes at different and changing potentials, respective to a single reference electrode, were performed simultaneously. The signal generation, signal processing and the analytical system were controlled by a computer (PC type) and special software. An improved sensor sensitivity was achieved by multielectrode detection and averaging of the IDA responses. By applying both the oxidation and reduction potentials of reversible redox molecules to pairs of the interdigitated electrodes, an increased current generation can be observed. Thus the steady state current of mediators such as benzoquinone can be amplified by a factor of 30 compared with conventional eIectrodes. This measuring principle was applied to determine of the activity of hydrolases by detecting the enzyme generated p-aminophenol in the nanomolar range. By combining both, the averaging and the recycling procedures, the detection limit of amperometric biosensing devices may be lowered by about one and a half orders of magnitude.
引用
收藏
页码:697 / 705
页数:9
相关论文
共 50 条
  • [1] Perspectives for microelectrode arrays for biosensing and membrane electroporation
    Neumann, E
    Tönsing, K
    Siemens, P
    [J]. BIOELECTROCHEMISTRY, 2000, 51 (02): : 125 - 132
  • [2] Editorial on the Special Issue on Microelectrode Arrays and Application to Medical Devices
    Salari, Alinaghi
    Dalton, Colin
    [J]. MICROMACHINES, 2020, 11 (08)
  • [3] Spheroids on microelectrode arrays: A highly sensitive system for biosensing applications
    Daus, A.
    Thielemann, C.
    [J]. EUROPEAN JOURNAL OF CELL BIOLOGY, 2010, 89 : 67 - 68
  • [4] Flexible microelectrode arrays with integrated insertion devices
    O'Brien, DP
    Nichols, TR
    Allen, MG
    [J]. 14TH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 2001, : 216 - 219
  • [5] NEW MICROELECTRONIC DEVICES BASED ON MODIFICATION OF MICROELECTRODE ARRAYS
    WRIGHTON, MS
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1986, 191 : 120 - ANYL
  • [6] Microelectrode arrays and microfabricated devices in electrochemical stripping analysis
    Beni, Valerio
    Arrigan, Damien W. M.
    [J]. CURRENT ANALYTICAL CHEMISTRY, 2008, 4 (03) : 229 - 241
  • [7] 3-D printed adjustable microelectrode arrays for electrochemical sensing and biosensing
    Yang, Haipeng
    Rahman, Md Taibur
    Du, Dan
    Panat, Rahul
    Lin, Yuehe
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2016, 230 : 600 - 606
  • [8] Reversible Integration of Microfluidic Devices with Microelectrode Arrays for Neurobiological Applications
    Grygoryev K.
    Herzog G.
    Jackson N.
    Strutwolf J.
    Arrigan D.W.M.
    McDermott K.
    Galvin P.
    [J]. Grygoryev, K. (konstantin.grygoryev@tyndall.ie), 1600, Springer Science and Business Media, LLC (04): : 263 - 275
  • [9] MODIFICATION OF MICROELECTRODE ARRAYS - NEW MICROELECTROCHEMICAL DEVICES FOR SENSOR APPLICATIONS
    WRIGHTON, MS
    THACKERAY, JW
    NATAN, MJ
    SMITH, DK
    LANE, GA
    BELANGER, D
    ALBERRY, WJ
    [J]. PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY OF LONDON SERIES B-BIOLOGICAL SCIENCES, 1987, 316 (1176) : 13 - 30
  • [10] A biosensing system employing nanowell microelectrode arrays to record the intracellular potential of a single cardiomyocyte
    Xiang, Yuting
    Liu, Haitao
    Yang, Wenjian
    Xu, Zhongyuan
    Wu, Yue
    Tang, Zhaojian
    Zhu, Zhijing
    Zeng, Zhiyong
    Wang, Depeng
    Wang, Tianxing
    Hu, Ning
    Zhang, Diming
    [J]. MICROSYSTEMS & NANOENGINEERING, 2022, 8 (01)