NMR ANGIOGRAPHY OF CORONARY VESSELS WITH 2-D PLANAR IMAGE SCANNING

被引:41
|
作者
CHO, ZH [1 ]
MUN, CW [1 ]
FRIEDENBERG, RM [1 ]
机构
[1] UNIV CALIF IRVINE, DEPT RADIOL SCI, IRVINE, CA 92717 USA
关键词
D O I
10.1002/mrm.1910200114
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
On the basis of the principles of the time‐of‐flight method and the 3‐D angiogram obtained by the 2‐D planar image scanning technique using 90° RF pulses with short repetition time, we have obtained a coronary angiogram around the heart including the coronary arteries and veins. The cine NMR imaging technique is also incorporated in synchronizing ECG R waves to reduce the motion artifact and at the same time to induce the saturation effect on the static samples. Images of the large bulk blood flow corresponding to the heart chamber and descending aorta are further removed by postprocessing. The final 3‐D angiogram is then formed by stacking the 2‐D images and contrast is further enhanced by the maximum ray tracing algorithm. © 1991 Academic Press, Inc. Copyright © 1991 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:134 / 143
页数:10
相关论文
共 50 条
  • [1] A 2-D Piezoelectric Actuated Scanning Image Acquisition
    Gu, Kebin
    Lee, Chi-June
    Wu, Chun-Wei
    Chien, Chih-Hsuan
    Wang, Wei-Chih
    HEALTH MONITORING OF STRUCTURAL AND BIOLOGICAL SYSTEMS 2013, 2013, 8695
  • [2] Dynamic intravenous coronary angiography using 2-D monochromatic synchrotron radiation
    Ohtsuka, S
    Sugishita, Y
    Takeda, T
    Itai, Y
    Hyodo, K
    Ando, M
    CIRCULATION, 1997, 96 (08) : 430 - 430
  • [3] THz 2-D Frequency Scanning Planar Integrated Array Antenna With Improved Efficiency
    Yao, Shi Sen
    Cheng, Yu Jian
    Wu, Ya Fei
    Yang, Hai Ning
    IEEE ANTENNAS AND WIRELESS PROPAGATION LETTERS, 2021, 20 (06): : 983 - 987
  • [4] Studies on Planar Reflectarrays with Spherical-Phase Distribution for 2-D Beam-Scanning
    Nayeri, Payam
    Yang, Fan
    Elsherbeni, Atef Z.
    2013 IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM (APSURSI), 2013, : 1670 - 1671
  • [5] 2-D SEISMIC VESSELS FOR 3-D MISSIONS
    SCHMIDT, VA
    SEA TECHNOLOGY, 1994, 35 (09) : 15 - &
  • [6] 3-D MR ANGIOGRAPHY WITH SCANNING 2-D IMAGES - SIMULTANEOUS DATA ACQUISITION OF ARTERIES AND VEINS (SAAV)
    KIM, JH
    CHO, ZH
    MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (03) : 554 - 561
  • [7] 2-D fiberoptic scanning microdisplay system
    Wang, Wei-Chih
    Tsui, Chi-Leung
    Lau, Fai-Hon
    Perez, Alex
    Chuang, Wei-Ching
    NANOSENSORS AND MICROSENSORS FOR BIO-SYSTEMS 2008, 2008, 6931
  • [8] Optical system enables 2-D scanning
    Boas, G
    PHOTONICS SPECTRA, 2001, 35 (12) : 43 - 44
  • [9] 2-D distance image sensor
    Mori, Toshihiro
    Journal of Robotics and Mechatronics, 2003, 15 (03) : 356 - 357
  • [10] 2-D NMR analysis of ethylcellulose.
    Xu, QW
    Brickhouse, M
    Wang, HM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2001, 221 : U354 - U354