PRECISION PARAMETERS FOR THE FDA SHELLFISH LABORATORY QUALITY ASSURANCE PROGRAM FOR 1973-1989

被引:0
|
作者
PEELER, JT
GRAHAM, TE
MATURIN, LJ
机构
[1] US FDA,QUAL ASSURANCE BRANCH LAB,SUMMIT ARGO,IL 60501
[2] US FDA,CTR FOOD SAFETY & APPL NUTR,WASHINGTON,DC 20204
关键词
STAPHYLOCOCCUS AUREUS; MOST PROBABLE NUMBER; SHELLFISH QUALITY ASSURANCE PROGRAM;
D O I
10.4315/0362-028X-58.6.648
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Precision parameters from four microbiological analytical methods (coliform most probable number [MPN], fecal coliform MPN, Staphylococcus aureus plate count and standard plate count) were computed for the Shellfish Quality Assurance Program of the U.S. Food and Drug Administration (FDA). The pooled reproducibility variance (S-R(2)) for the four methods from 1973 to 1989 were 0.0778, 0.1181, 0.0137, and 0.0087, respectively.
引用
收藏
页码:648 / 650
页数:3
相关论文
共 50 条
  • [1] LABORATORY QUALITY ASSURANCE PROGRAM
    WEISS, PJ
    [J]. AMERICAN JOURNAL OF PHARMACY, 1971, 143 (03): : 96 - &
  • [2] A QUALITY ASSURANCE PROGRAM FOR THE HISTOPATHOLOGY LABORATORY
    WEDDINGTON, HG
    [J]. JOURNAL OF MEDICAL TECHNOLOGY, 1984, 1 (12): : 909 - 912
  • [3] A QUALITY ASSURANCE PROGRAM FOR THE HISTOPATHOLOGY LABORATORY
    WEDDINGTON, HG
    [J]. JOURNAL OF MEDICAL TECHNOLOGY, 1985, 2 (05): : 321 - 322
  • [4] PRECISION PARAMETERS FOR AOAC BACILLUS-STEAROTHERMOPHILUS DISK ASSAY BASED ON FDA MILK LABORATORY QUALITY ASSURANCE 1982-1986 SAMPLES
    PEELER, JT
    MESSER, JW
    HOUGHTBY, GA
    LESLIE, JE
    BARNETT, JE
    [J]. JOURNAL OF FOOD PROTECTION, 1989, 52 (12) : 867 - 870
  • [5] ELEMENTS OF A LABORATORY QUALITY-ASSURANCE PROGRAM
    DRESSMAN, RC
    [J]. JOURNAL AMERICAN WATER WORKS ASSOCIATION, 1982, 74 (10): : 42 - 42
  • [6] Cardiac catheterization laboratory imaging quality assurance program
    Wondrow, MA
    Laskey, WK
    Hildner, FJ
    Cusma, J
    Holmes, DR
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 52 (01) : 59 - 66
  • [7] Implementation of a Laboratory Quality Assurance Program: The Louisville Experience
    Metz, Michael J.
    Abdel-Azim, Tamer
    Miller, Cynthia J.
    Lin, Wei-Shao
    ZandiNejad, Amirali
    Oliveira, Gustavo M.
    Morton, Dean
    [J]. JOURNAL OF DENTAL EDUCATION, 2014, 78 (02) : 195 - 205
  • [8] THE ANDROLOGY LABORATORY IN AN ASSISTED REPRODUCTIVE TECHNOLOGIES PROGRAM - QUALITY ASSURANCE AND LABORATORY METHODOLOGY
    MULLER, CH
    [J]. JOURNAL OF ANDROLOGY, 1992, 13 (05): : 349 - 360
  • [9] A COOPERATIVE QUALITY ASSURANCE PROGRAM FOR MONITORING CONTRACT LABORATORY PERFORMANCE
    KINGSLEY, BA
    GIN, C
    PEIFER, WR
    STIVERS, DF
    ALLEN, SH
    BRASS, HJ
    GLICK, EM
    WEISNER, MJ
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1980, 180 (AUG): : 119 - ENVR
  • [10] IN-HOUSE QUALITY ASSURANCE PROGRAM IN A STATE CYTOLOGY LABORATORY
    GARDNER, NM
    [J]. ACTA CYTOLOGICA, 1989, 33 (04) : 487 - 488