COMPUTER-AIDED ANALYSIS OF GASTROINTESTINAL PRESSURE RECORDINGS - COMPARISON WITH MANUAL SCORING

被引:4
|
作者
MELSEN, NC
ANDERSEN, MB
KRAGLUND, K
JUHL, B
机构
[1] AARHUS UNIV,INST EXPTL CLIN RES,DK-8000 AARHUS,DENMARK
[2] AARHUS UNIV HOSP,DEPT SURG GASTROENTEROL,DK-8000 AARHUS,DENMARK
关键词
COMPUTER ANALYSIS; GASTROINTESTINAL MOTILITY; MANOMETRY;
D O I
10.3109/00365529209011188
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
The aim of the present study was to compare computer-based and visual/manual scoring of pressure recordings from the gastric antrum and duodenum. The computer system was based on three separate principles of recognition: moving average, tracking base line, and threshold filters. Computer scoring resulted in the detection of more contractions than visual/manual scoring, owing to inclusion of artefacts of duration and amplitude above the selected thresholds. Owing to its unreliability, visual/manual scoring led to inclusion of some contractions of below-borderline amplitude or duration. The median difference in the frequency of contractions was, however, 0 min-1. There was close agreement on amplitudes of contractions. As the differences between visual/manual analysis and computer-aided scoring by the present system are of an unimportant magnitude and as computer-based scoring is consistent, we conclude that computer-aided analysis is preferable to visual/manual analysis.
引用
收藏
页码:805 / 811
页数:7
相关论文
共 50 条
  • [1] CONSISTENCY IN MANUAL SCORING ANALYSIS OF GASTROINTESTINAL PRESSURE RECORDINGS
    ANDERSEN, MB
    STODKILDEJORGENSEN, H
    KRAGLUND, K
    DJURHUUS, JC
    ROSENFALCK, A
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1989, 24 (03) : 321 - 328
  • [2] COMPUTER-AIDED ANALYSIS OF GASTROINTESTINAL MOTILITY
    GRUNDY, D
    SCRATCHERD, T
    SCRATCHERD, TJ
    JOURNAL OF PHYSIOLOGY-LONDON, 1983, 342 (SEP): : P4 - P4
  • [3] COMPUTER-AIDED ANALYSIS OF GASTROINTESTINAL MYOELECTRIC ACTIVITY
    LATOUR, A
    FERRE, JP
    JOURNAL OF BIOMEDICAL ENGINEERING, 1985, 7 (02): : 127 - 131
  • [4] Manual and computer-aided space analysis: A comparative study
    Schirmer, UR
    Wiltshire, WA
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1997, 112 (06) : 676 - 680
  • [5] Comparison of manual and computer-aided breast cancer biopsy grading
    Schnorrenberg, F
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 1166 - 1167
  • [6] Comparison of computer-aided and manual measurements in the evaluation of carpal alignment
    Sippo, Robert
    Huuska, Kira
    Hoglund, Theresa
    Waris, Eero
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2024, 49 (08) : 987 - 994
  • [7] Combined Manual Reading and Computer-Aided Quantitative Analysis for the Standardization of HER2 IHC Scoring
    Sanchez-Salazar, Alma
    Alvarado, Ruben
    Ibraheem, Rabiu
    Steele, Cristina
    Walker, Dan
    Glickman, Yael
    LABORATORY INVESTIGATION, 2024, 104 (03) : S255 - S256
  • [8] MANUAL AND COMPUTER-AIDED SPACE ANALYSIS - A COMPARATIVE-STUDY
    SCHIRMER, UR
    YEN, CH
    JOURNAL OF DENTAL RESEARCH, 1995, 74 : 518 - 518
  • [9] VARIANCE ANALYSIS AND COMPARISON IN COMPUTER-AIDED DESIGN
    Ullrich, Torsten
    Schiffer, Thomas
    Schinko, Christoph
    Fellner, Dieter W.
    4TH ISPRS INTERNATIONAL WORKSHOP 3D-ARCH 2011: 3D VIRTUAL RECONSTRUCTION AND VISUALIZATION OF COMPLEX ARCHITECTURES, 2011, 38-5 (W16): : 149 - 153
  • [10] COMPUTER-AIDED ANALYSIS OF HUMAN ESOPHAGEAL PERISTALSIS .1. TECHNICAL DESCRIPTION AND COMPARISON WITH MANUAL ANALYSIS
    CASTELL, DO
    DUBOIS, A
    DAVIS, CR
    CORDOVA, CM
    NORMAN, DO
    DIGESTIVE DISEASES AND SCIENCES, 1984, 29 (01) : 65 - 72