USE OF CYCLOTRONS FOR TRACE-ELEMENT ANALYSIS IN BIOLOGICAL SAMPLES AND RELATED METABOLISM STUDIES

被引:3
|
作者
MOLHO, N
CANTONE, MC
DEBARTOLO, D
GAMBARINI, G
GIUSSANI, A
PIROLA, L
ROTH, P
WERNER, E
HANSEN, C
机构
[1] FORSCHUNGSZENTRUM UMWELT & GESUNDHEIT,GSF,FRANKFURT,GERMANY
[2] UNIV MILAN,I-20122 MILAN,ITALY
关键词
D O I
10.1016/0168-583X(93)95413-Y
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this work metabolic studies based on proton nuclear activation (PNA) are described. For such kind of experiments a very high sensitivity in concentration determination of adequate tracers in biological tissues is needed and the contemporary use of more than one isotope of some element is often necessary. Moreover the use of radioactive tracers is normally forbidden in healthy persons. PNA is usually obtained inducing (p, xn) reactions on the target nuclei by means of a proton beam of adequate energy. The large power released by the charged particle beam in biological targets (dried serum samples) requires an efficient cooling system and imposes a limitation in the beam intensity. The special irradiation chamber built to irradiate 30 samples at a time is described. An account will be given of metabolic studies on Fe, Mo, and Te in man and/or animal. Some fundamental metabolic parameters are extracted by means of compartment analysis. Data on blood serum clearance constants and relative intestinal absorption coefficients are discussed.
引用
收藏
页码:560 / 563
页数:4
相关论文
共 50 条
  • [1] TRACE-ELEMENT ANALYSIS OF BIOLOGICAL SAMPLES
    VEILLON, C
    [J]. ANALYTICAL CHEMISTRY, 1986, 58 (08) : A851 - &
  • [2] ACCURACY OF TRACE-ELEMENT ANALYSIS IN BIOLOGICAL SAMPLES
    FELL, GS
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1984, 3 (07) : R9 - R10
  • [3] THE ACCURACY IN TRACE-ELEMENT ANALYSIS OF BIOLOGICAL SAMPLES
    SCHMITT, Y
    [J]. 6TH INTERNATIONAL TRACE ELEMENT SYMP 1989, VOLS 1-5, 1989, : 387 - 394
  • [4] ACTIVATION-ANALYSIS TRACE-ELEMENT STUDIES OF MARINE BIOLOGICAL SAMPLES
    GOEIJ, JJMD
    GUINN, VP
    YOUNG, DR
    [J]. TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1972, 15 (02): : 642 - +
  • [5] THE ACCURACY SYNDROME IN TRACE-ELEMENT ANALYSIS OF BIOLOGICAL SAMPLES
    CAROLI, S
    [J]. MICROCHEMICAL JOURNAL, 1992, 45 (03) : 257 - 271
  • [6] THE VALIDATION OF A PIXE SYSTEM FOR TRACE-ELEMENT ANALYSIS OF BIOLOGICAL SAMPLES
    SAIED, SO
    CRUMPTON, D
    FRANCOIS, PE
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1981, 181 (1-3): : 53 - 57
  • [7] DATABASE FOR TRACE-ELEMENT CONCENTRATIONS IN BIOLOGICAL SAMPLES
    VESTERBERG, O
    NORDBERG, G
    BRUNE, D
    [J]. FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 332 (06): : 556 - 560
  • [8] APPLICATION OF FTIR, PIXE, AND EBS FOR TRACE-ELEMENT ANALYSIS IN BIOLOGICAL SAMPLES
    KWIATEK, WM
    LEKKI, J
    PALUSZKIEWICZ, C
    PREIKSCHAS, N
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1992, 64 (1-4): : 512 - 516
  • [9] THE APPLICATION OF SYNCHROTRON RADIATION TO MICROPROBE TRACE-ELEMENT ANALYSIS OF BIOLOGICAL SAMPLES
    GORDON, BM
    HANSON, AL
    JONES, KW
    POUNDS, JG
    RIVERS, ML
    SCHIDLOVSKY, G
    SPANNE, P
    SUTTON, SR
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 45 (1-4): : 527 - 531
  • [10] SAMPLE CONTAMINATION AS A SOURCE OF ERROR IN TRACE-ELEMENT ANALYSIS OF BIOLOGICAL SAMPLES
    VERSIECK, J
    BARBIER, F
    CORNELIS, R
    HOSTE, J
    [J]. TALANTA, 1982, 29 (11) : 973 - 984