A COMPARISON OF THE EFFECTS OF PROPOFOL AND NITROUS-OXIDE ON THE ELECTROENCEPHALOGRAM IN EPILEPTIC PATIENTS DURING CONSCIOUS SEDATION FOR DENTAL PROCEDURES

被引:0
|
作者
OEILIM, VLB
KALKMAN, CJ
BOUVYBERENDS, ECM
MEYJES, EFP
MAKKES, PC
VERMEULENCRANCH, DME
ODOOM, JA
VANWEZEL, HB
BOVILL, JG
机构
[1] UNIV AMSTERDAM, ACAD MED CTR, DEPT CLIN NEUROPHYSIOL, 1105 AZ AMSTERDAM, NETHERLANDS
[2] LEIDEN UNIV, DEPT ANESTHESIOL, 2300 RA LEIDEN, NETHERLANDS
[3] DEPT SPECIAL CARE DENT, CRAEYENBURCH, NETHERLANDS
来源
ANESTHESIA AND ANALGESIA | 1992年 / 75卷 / 05期
关键词
D O I
暂无
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The influence of sedative doses of propofol or nitrous oxide on the electroencephalogram was studied in 11 mentally handicapped patients with treated epilepsy undergoing dental procedures. At one session, propofol was titrated to achieve conscious sedation. The mean (+/-SD) dose requirements were 5.5 +/- 1.1 mg. kg-1.h-1. In six patients, the electroencephalogram was unchanged during propofol administration. In three patients, there was a decrease in epileptic activity, and in two patients, paroxysmal discharges disappeared. At another session, nitrous oxide was administered by nasal mask. The mean (+/-SD) concentration of nitrous oxide needed was 43.6% +/- 4.8%. The electroencephalogram did not change in nine patients, whereas in two patients epileptic activity d There were no clinical epileptoid or other adverse manifestations during any treatment or up to 48 h thereafter. The results of the present study suggest that propofol or nitrous oxide can be administered in subanesthetic doses for conscious sedation in mentally handicapped patients with treated epilepsy.
引用
收藏
页码:708 / 714
页数:7
相关论文
共 50 条
  • [1] COMPARISON OF NITROUS-OXIDE CONCENTRATIONS IN A DENTAL PRACTICE, WITH AND WITHOUT INHALATION SEDATION SCAVENGING
    MALLETT, J
    SHER, A
    MOYES, DG
    CLEATONJONES, P
    JOURNAL OF DENTAL RESEARCH, 1984, 63 (04) : 592 - 592
  • [2] RELATIONSHIP BETWEEN NITROUS-OXIDE CONSCIOUS SEDATION AND THE HYPNOTIC STATE
    BARBER, J
    DONALDSON, D
    RAMRAS, S
    ALLEN, GD
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1979, 99 (04): : 624 - 626
  • [3] EFFECTS OF NITROUS-OXIDE ON MEMORY FOR INSTRUCTIONS IN DENTAL PATIENTS
    FILE, SE
    BALAKRISHNAN, J
    MURRAY, A
    HARRIS, A
    SKELLY, AM
    HUMAN PSYCHOPHARMACOLOGY-CLINICAL AND EXPERIMENTAL, 1992, 7 (01) : 37 - 44
  • [4] EFFECT OF NITROUS-OXIDE SEDATION ON BLOOD-PRESSURE OF PEDIATRIC DENTAL PATIENTS
    ASPES, T
    JOURNAL OF DENTISTRY FOR CHILDREN, 1975, 42 (05): : 32 - 34
  • [5] PROPOFOL INDUCTION AND MAINTENANCE WITH NITROUS-OXIDE IN PEDIATRIC OUTPATIENT DENTAL-ANESTHESIA - A COMPARISON WITH THIOPENTONE NITROUS OXIDE HALOTHANE
    PUTTICK, N
    ROSEN, M
    ANAESTHESIA, 1988, 43 (08) : 646 - 649
  • [6] INSPIRED OXYGEN AND NITROUS-OXIDE CONCENTRATIONS IN VOLUNTEERS DURING NITROUS-OXIDE SEDATION WITH A HUDSON MASK
    ANDERSON, BJ
    DYSON, A
    HENDERSON, AM
    ANAESTHESIA AND INTENSIVE CARE, 1988, 16 (04) : 423 - 426
  • [7] Effects of nitrous oxide sedation on resting electroencephalogram topography
    Foster, Brett L.
    Liley, David T. J.
    CLINICAL NEUROPHYSIOLOGY, 2013, 124 (02) : 417 - 423
  • [8] Comparison of propofol sedation versus conscious sedation during endosonography
    Nayar, DS
    Feuerman, M
    Scheinberg, L
    Gress, F
    GASTROINTESTINAL ENDOSCOPY, 2004, 59 (05) : AB126 - AB126
  • [9] Conscious Sedation Using Nitrous Oxide and Midazolam for Dental Procedures in Pediatric Patients in Armed Forces Hospital - Our Experience
    Singh, Gunjan
    Jahan, Nikahat
    Sharma, Vineet
    Dhiman, Manoj
    Bhattal, Hiteshwar
    Yadav, Rahul
    Chakrabarty, Anubhav
    JOURNAL OF MARINE MEDICAL SOCIETY, 2024, 26 (03) : 426 - 429
  • [10] BISPECTRAL ANALYSIS OF THE ELECTROENCEPHALOGRAM CORRELATES WITH PATIENT MOVEMENT TO SKIN INCISION DURING PROPOFOL NITROUS-OXIDE ANESTHESIA
    KEARSE, LA
    MANBERG, P
    CHAMOUN, N
    DEBROS, F
    ZASLAVSKY, A
    ANESTHESIOLOGY, 1994, 81 (06) : 1365 - 1370