The relationship between computed tomography measurement of the optic nerve sheath diameter and elevated intracranial pressure in non-trauma patients

被引:5
|
作者
Luyt, Daniel [1 ]
Hurter, Delme [2 ]
Joubert, Gina [3 ]
机构
[1] Univ Free State, Dept Clin Imaging Sci, Bloemfontein, South Africa
[2] Kimberley Hosp Complex, Dept Radiol, Kimberley, South Africa
[3] Univ Free State, Dept Biostat, Bloemfontein, South Africa
来源
SA JOURNAL OF RADIOLOGY | 2016年 / 20卷 / 01期
关键词
D O I
10.4102/sajr.v20i1.1060
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The early detection and treatment of raised intracranial pressure (ICP) is critical in the prevention of mortality and morbidity as a result of secondary ischemic brain injury. Measuring the optic nerve sheath diameter (ONSD) on computed tomography (CT) to predict raised ICP may be useful in cases where routine CT investigations of the brain are indicated and invasive ICP monitoring is not available, or a lumbar puncture (LP) is contraindicated. Objective: The purpose of this study was to determine if the ONSD can be measured on digital images obtained by routine CT investigations of the brain, to identify patients with non-traumatic causes of elevated ICP, and to provide the observer with a non-invasive, objective measurement to predict elevated ICP. Method: We conducted a cross-sectional, retrospective analysis of anonymised patient data, comparing the ONSD on CT imaging with the opening pressure manometry during LP on patients who presented with focal neurology or with a Glasgow coma scale score of less than 15. The study sample consisted of 67 patients, >= 18 years of age, treated at the emergency department of the Kimberly Hospital Complex from 01 March 2013 to 31 December 2014. Results: An ONSD measurement of >= 4.8 mm identified patients with an elevated ICP with a sensitivity of 92.9% and a specificity of 97.6%, using a 95% confidence interval. Raising the ONSD cut-off value to >= 5.0 mm decreased the sensitivity to 85.7% but increased the specificity to 100%, eliminating all patients with a normal ICP. Conclusion: The ONSD can be measured on digital images obtained by routine CT investigations of the brain to predict elevated ICP in non-trauma patients, >= 18 years of age, with acceptable sensitivity and specificity.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Relationship between the measurement by tomography and ultrasound of the diameter of the optic nerve sheath as a non-invasive estimator of intracranial pressure
    Rojas-Murillo, Tania
    Olvera-Gonzalez, Natael
    CIRUGIA Y CIRUJANOS, 2022, 90 (02): : 236 - 241
  • [2] Transocular ultrasound measurement of the optic nerve sheath diameter can identify elevated intracranial pressure in trauma patients
    Nash, Joshua E.
    O'Rourke, Colin
    Moorman, Matthew L.
    TRAUMA-ENGLAND, 2016, 18 (01): : 28 - 34
  • [3] Comparison of ultrasonography and computed tomography for measuring optic nerve sheath diameter for the detection of elevated intracranial pressure
    Kim, Dae Yong
    Kim, Sin Young
    Hong, Dae Young
    Sung, Bo Youn
    Lee, Sung
    Paik, Jin Hui
    Jung, Hyun Min
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2021, 204
  • [4] The association between intracranial pressure and optic nerve sheath diameter on patients with head trauma
    Celik, Kaan
    Demiryurek, Bekir Enes
    ARQUIVOS DE NEURO-PSIQUIATRIA, 2021, 79 (10) : 879 - 885
  • [5] ASSOCIATION BETWEEN OPTIC NERVE SHEATH DIAMETER ON COMPUTED TOMOGRAPHY AND INTRACRANIAL PRESSURE IN PATIENTS WITH SEVERE TRAUMATIC BRAIN INJURY
    Sekhon, M. S.
    Griesdale, D. E.
    Robba, C.
    Needham, E.
    Walland, K.
    McGlashan, N.
    Mossallum, R.
    Menon, D. K.
    INTENSIVE CARE MEDICINE, 2014, 40 : S19 - S19
  • [6] Ultrasound measurement of optic nerve sheath diameter is not a reliable predictor of intracranial pressure in adult trauma patients
    Kwan, Rita O.
    Ereso, Alexander Q.
    Cureton, Elizabeth
    Dozier, Kristopher
    Castro-Moure, Frederico
    Patel, Atul
    Sadjadi, Javid
    Victorino, Gregory P.
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2009, 209 (03) : S61 - S61
  • [7] Optic nerve sheath diameter ultrasonography for elevated intracranial pressure detection
    Wang Li-Juan
    Chen Hong-Xiu
    Chen Ying
    Yu Ze-Yang
    Xing Ying-Qi
    ANNALS OF CLINICAL AND TRANSLATIONAL NEUROLOGY, 2020, 7 (05): : 865 - 868
  • [8] Correlations between optic nerve sheath diameters measured using computed tomography and elevated intracranial pressure levels
    Jalayondeja, Tinapas
    Urasyanandana, Karanarak
    INTERDISCIPLINARY NEUROSURGERY-ADVANCED TECHNIQUES AND CASE MANAGEMENT, 2021, 26
  • [9] Optic nerve sheath diameter and intracranial pressure
    Dubourg, Julie
    Javouhey, Etienne
    Messerer, Mahmoud
    JOURNAL OF NEUROSURGERY-PEDIATRICS, 2012, 9 (05) : 570 - 571
  • [10] Correlation of optic nerve sheath diameter with direct measurement of intracranial pressure
    Kimberly, Heidi Harbison
    Shah, Sachita
    Marill, Keith
    Noble, Vicki
    ACADEMIC EMERGENCY MEDICINE, 2008, 15 (02) : 201 - 204