TEMPERATURE ERROR IN RADIATION THERMOMETRY CAUSED BY EMISSIVITY AND REFLECTANCE MEASUREMENT ERROR

被引:32
|
作者
CORWIN, RR
RODENBURGH, A
机构
[1] Beta Industries, Inc., Dayton, OH, 45429
来源
APPLIED OPTICS | 1994年 / 33卷 / 10期
关键词
RADIATION THERMOMETRY; TEMPERATURE ERROR; EMISSIVITY; REFLECTANCE; SPECULAR AND DIFFUSE REFLECTING COMPONENTS;
D O I
10.1364/AO.33.001950
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A general expression for the temperature error caused by emissivity uncertainty is developed, and it is concluded that lower-wavelength systems provide significantly less temperature error. A technique to measure the normal emissivity is proposed that uses a normally incident light beam and an aperture to collect a portion of the energy reflected from the surface and to measure essentially both the specular component and the biangular reflectance at the edge of the aperture. The theoretical results show that the aperture size need not be substantial to provide reasonably low temperature errors for a broad class of materials and surface reflectance conditions.
引用
收藏
页码:1950 / 1957
页数:8
相关论文
共 50 条
  • [1] Temperature error in casting radiation thermometry caused by emissivity error and measurement wavelength
    Chen, Liang
    Gao, Hongwei
    Zhao, Yawei
    Yu, Yang
    Wang, David
    ICIEA 2008: 3RD IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, PROCEEDINGS, VOLS 1-3, 2008, : 1047 - +
  • [2] Temperature measurement decreasing measurement error caused by stray lights and unpredictable emissivity
    Ino, T
    Yamada, W
    Suzuki, H
    Tsumura, A
    Akama, Y
    Nishida, N
    OPTICAL ENGINEERING FOR SENSING AND NANOTECHNOLOGY (ICOSN 2001), 2001, 4416 : 215 - 218
  • [3] Automatic emissivity measurement setup for industrial radiation thermometry
    Schmidt, V
    Meitzner, S
    Sandring, H
    King, P
    TEMPERATURE: ITS MEASUREMENT AND CONTROL IN SCIENCE AND INDUSTRY, VOL 7, PTS 1 AND 2, 2003, 684 : 723 - 728
  • [4] Prediction of error caused by temperature effects in ultrasonic thickness measurement
    Chang, RR
    Shu, CM
    Chang, MK
    Chow, NM
    MATERIALS EVALUATION, 2004, 62 (01) : 69 - 72
  • [5] EMISSIVITY OF METALS FOR RADIATION THERMOMETRY
    MIZUNO, M
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1985, 71 (05): : S390 - S390
  • [6] EMISSIVITY OF METALS FOR RADIATION THERMOMETRY
    MIZUNO, M
    KON, K
    UTSUNO, M
    TRANSACTIONS OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1985, 25 (10) : B253 - B253
  • [7] On the effects of temperature dependence of spectral emissivity in industrial radiation thermometry
    Saunders, P
    HIGH TEMPERATURES-HIGH PRESSURES, 2001, 33 (05) : 599 - 610
  • [8] ERROR ANALYSIS FOR EMISSIVITY MEASUREMENT USING FTIR SPECTROMETER
    Yan, Kai
    Ren, Huazhong
    Hu, Ronghai
    Mu, Xihan
    Liu, Zhao
    Yan, Guangjian
    2013 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2013, : 3080 - 3083
  • [9] Comparison of temperature measurement by noise thermometry and radiation thermometry
    Neuer, G
    Fischer, J
    Edler, F
    Thomas, R
    MEASUREMENT, 2001, 30 (03) : 211 - 221
  • [10] The patient: A novel source of error in clinical temperature measurement using infrared aural thermometry
    Heusch, AI
    McCarthy, PW
    JOURNAL OF ALTERNATIVE AND COMPLEMENTARY MEDICINE, 2005, 11 (03) : 473 - 476