FRACTURE LOAD OF CERAMIC BALL HEADS OF HIP-JOINT PROSTHESES

被引:8
|
作者
DORRE, E
RICHTER, HG
WILLMANN, G
机构
来源
BIOMEDIZINISCHE TECHNIK | 1991年 / 36卷 / 12期
关键词
ORTHOPEDIC SURGERY; HIP JOINT PROSTHESIS; FEMORAL HEAD; BIOCERAMICS; ALUMINA; MECHANICAL STRENGTH; SAFETY;
D O I
10.1515/bmte.1991.36.12.305
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To ensure the stability of ceramic ball heads of hip joint prostheses over the long term, both standards for the material and FDA-regulations for the components have been established. In this paper the philosophy underlying design and reliability is discussed. On the basis of fracture loads determined for Biolox ball heads the high level of stability and reliability that has been achieved and can now be guaranteed, is demonstrated.
引用
收藏
页码:305 / 307
页数:3
相关论文
共 50 条
  • [1] Influence of contaminants in the stem-ball interface on the static fracture load of ceramic hip joint ball heads
    Weisse, B.
    Affolter, C.
    Stutz, A.
    Terrasi, G. P.
    Koebel, S.
    Weber, W.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2008, 222 (H5) : 829 - 835
  • [2] EVALUATION OF STRESSES IN CERAMIC HIP-JOINT HEADS
    KLEER, G
    SIEGELE, D
    SOLTESZ, U
    [J]. JOURNAL OF BIOMECHANICS, 1985, 18 (07) : 539 - 539
  • [3] ASSORTED ALUMINUM-OXIDE CERAMIC HEADS FOR PROSTHESES OF HIP-JOINT - PRELIMINARY COMMUNICATION
    WEBER, BG
    FREY, O
    SEMLITSCH, M
    DORRE, E
    [J]. ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1977, 115 (03): : 305 - 309
  • [4] THE EFFECTS OF HARDNESS AND SURFACE QUALITY OF METAL TAPERS ON THE FRACTURE LOAD OF CERAMIC BALL HEADS IN HIP ENDOPROSTHESES
    BACHNICK, M
    HASENPUSCH, M
    RICHTER, H
    BOENICK, U
    [J]. BIOMEDIZINISCHE TECHNIK, 1994, 39 (12): : 302 - 306
  • [5] EFFECTS OF LUBRICATION IN HIP-JOINT PROSTHESES
    UNSWORTH, A
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1978, 23 (02): : 253 - 268
  • [6] STRESS-ANALYSIS IN CERAMIC HIP-JOINT HEADS OF VARIOUS SHAPES AND FITTINGS
    SOLTESZ, U
    HEIMKE, G
    [J]. JOURNAL OF BIOMECHANICS, 1982, 15 (10) : 809 - 809
  • [7] HYDROXYAPATITE CERAMIC COATINGS FOR ANCHORING COMPONENTS OF HIP-JOINT PROSTHESES (TECHNICAL ASPECTS)
    DORRE
    [J]. BIOMEDIZINISCHE TECHNIK, 1989, 34 (03): : 46 - 52
  • [8] LUBRICATION MECHANISM OF HIP-JOINT REPLACEMENT PROSTHESES
    WEIGHTMA.B
    ROSE, R
    SIMON, S
    PAUL, I
    RADIN, E
    [J]. MECHANICAL ENGINEERING, 1972, 94 (10): : 65 - &
  • [9] DIGITAL SUBTRACTION ARTHROGRAPHY OF HIP-JOINT PROSTHESES
    VANDERLANDE, BAE
    VANHELMOND, EPM
    SCHOLTEN, ET
    DRIESSEN, APPM
    [J]. DIAGNOSTIC IMAGING IN CLINICAL MEDICINE, 1986, 55 (4-5) : 228 - 232
  • [10] EXPERIENCE IN 77 CHANGES OF HIP-JOINT PROSTHESES
    WOLF, L
    [J]. ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1978, 116 (02): : 248 - 254