Distal mechanical protection in percutaneous coronary interventions

被引:0
|
作者
Boztosun, Bilal [1 ]
Donmez, Guclu [1 ]
Kirma, Cevat [1 ]
机构
[1] Kofluyolu Kalp Egitim & Arastirma Hastanesi, Kardiyol Bolumu, Istanbul, Turkey
关键词
Angioplasty; transluminal; percutaneous coronary; balloon dilatation/instrumentation/methods; catheterization/instrumentation; coronary angiography; embolism/etiology/prevention & control; equipment design; filtration; myocardial infarction; stents;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The occurrence of fatal events after percutaneous coronary interventions associated with distal embolization of plaque contents has led to the development of new protection strategies. Firstly, pharmacological methods were attempted to deal with the emboli and accompanying myocardial ischemia. Among them, glycoprotein IIb-IIIa receptor antagonists were shown to be beneficial especially during primary percutaneous coronary interventions in patients with acute myocardial infarction. However, as far as the prevention of distal embolization was concerned, these medications were found not to offer a desirable efficacy especially in interventions for lesions with a heavy thrombus load, and in those involving degenerated saphenous vein grafts and carotid lesions. Today, several types of distal mechanical protection devices have been developed to prevent and/or treat distal embolization. They are classified under two headings, namely those having a filter system and a balloon system. The merits and demerits of these devices are reviewed in the light of the literature.
引用
收藏
页码:126 / 131
页数:6
相关论文
共 50 条
  • [1] Distal protection devices during percutaneous coronary and carotid interventions
    Fasseas, P
    Orford, JL
    Denktas, AE
    Berger, PB
    [J]. CURRENT CONTROLLED TRIALS IN CARDIOVASCULAR MEDICINE, 2001, 2 (06): : 286 - 291
  • [2] Distal protection devices during percutaneous coronary and carotid interventions
    Fasseas P.
    Orford J.L.
    Denktas A.E.
    Berger P.B.
    [J]. Trials, 2 (6) : 286 - 291
  • [3] Background and indications for distal protection devices in percutaneous coronary interventions
    Buellesfeld, L.
    Gerckens, U.
    Grube, E.
    [J]. DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2006, 131 (39) : 2160 - 2164
  • [4] The role of distal myocardial protection devices during percutaneous coronary interventions
    Gorog D.A.
    [J]. Current Treatment Options in Cardiovascular Medicine, 2007, 9 (1) : 52 - 59
  • [5] Filter no reflow during percutaneous coronary interventions using the Filterwire distal protection device
    Porto, I
    Choudhury, RP
    Pillay, P
    Burzotta, F
    Trani, C
    Niccoli, G
    Blackman, DJ
    Channon, KM
    Banning, AP
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2006, 109 (01) : 53 - 58
  • [6] Filter no-reflow during percutaneous coronary interventions using the filtewire distal protection device
    Porto, I
    Choudhury, RP
    Pillay, P
    Channon, KM
    Banning, AR
    [J]. EUROPEAN HEART JOURNAL, 2004, 25 : 312 - 312
  • [7] Distal embolization during primary percutaneous coronary interventions
    Kilickesmez, Kadriye Orta
    [J]. TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2013, 41 (06): : 495 - 496
  • [8] Devices for distal protection during percutaneous coronary revascularization
    Mauri, Laura
    Rogers, Campbell
    Baim, Donald S.
    [J]. CIRCULATION, 2006, 113 (22) : 2651 - 2656
  • [9] Use of FilterWire EX for distal embolic protection during complex percutaneous coronary interventions: Four case studies
    Kornowski, R
    Assali, A
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 58 (03) : 364 - 369
  • [10] Distal Protection During Percutaneous Coronary Intervention in Native Right Coronary Arteries
    El Mokhtari, E.
    Steinke, F.
    Krueger, D.
    Tiroke, A.
    Simon-Herrmann, G.
    Simon, R.
    Lins, M.
    [J]. JOURNAL FUR KARDIOLOGIE, 2007, 14 (11-12): : 333 - 334