We have developed a simulation to model position encoding multicrystal detectors for positron emission tomography. The simulation is designed to treat the interactions of energetic photons in a scintillator, the geometry of the multicrystal array, as well as the propagation and detection of individual scintillation photons. The simulation is tested with a model of the EXACT AR PLUS block detector manufactured by Siemens-CTI, Position and energy responses derived from the simulation are compared to measured ones. Line spread functions, for four columns of crystals, are reproduced with an accuracy of +/- 0.5 mm, The crystal-by-crystal photopeak pulse heights and FWHM's are also predicted within a range of +/- 14%, and (-6)(+9)%, respectively.
引用
收藏
页码:2236 / 2243
页数:8
相关论文
共 50 条
  • [1] Depth encoding multicrystal detectors for PET
    Natl Inst of Radiological Sciences, Chiba, Japan
    [J]. IEEE Trans Nucl Sci, 3 pt 2 (1152-1157):
  • [2] Depth encoding multicrystal detectors for PET
    Murayama, H
    Ishibashi, H
    Uchida, H
    Omura, T
    Yamashita, T
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 1152 - 1157
  • [3] An improved model for the energy resolution of multicrystal encoding detectors for PET
    Vozza, D
    Moisan, C
    Paquet, S
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (02) : 179 - 183
  • [4] Computer simulation for design of depth encoding multicrystal detector for PET
    Haneishi, H
    Nishiya, S
    Miyake, Y
    Murayama, H
    Omura, T
    Ishibashi, H
    [J]. 1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1207 - 1211
  • [5] Monte Carlo simulation for depth encoding multicrystal detector for PET
    Haneishi, H
    Yamada, A
    Takagi, K
    Murayama, H
    [J]. 2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1993 - 1996
  • [6] A depth encoding in multicrystal detector for PET
    Murayama, H
    Ishibashi, H
    Uchida, U
    Omura, T
    Yamashita, T
    [J]. 1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 1037 - 1041
  • [7] Performance studies of a depth encoding multicrystal detector for PET
    Moisan, C
    Tsang, G
    Rogers, JG
    Hoskinson, EM
    [J]. 1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1064 - 1068
  • [8] Performance studies of a depth encoding multicrystal detector for PET
    Moisan, C
    Tsang, G
    Rogers, JG
    Hoskinson, EM
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) : 1926 - 1931
  • [9] Performance studies of a depth encoding multicrystal detector for PET
    Moisan, C.
    Tsang, G.
    Rogers, J.G.
    Hoskinson, E.M.
    [J]. IEEE Transactions on Nuclear Science, 1996, 43 (3 pt 2): : 1926 - 1931
  • [10] Performance studies of depth encoding multicrystal detectors using avalanche photodiodes.
    Saoudi, A
    Rouleau, D
    Lecomte, R
    Andreaco, M
    Casey, M
    Nutt, R
    Dautet, H
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 92P - 92P