Transmuscular Migration of a Scleral Tunnel-Secured Encircling Silicone Band

被引:1
|
作者
Nishida, Yui [1 ]
Fukumoto, Masanori [1 ]
Kida, Teruyo [1 ]
Suzuki, Hiroyuki [1 ]
Ikeda, Tsunehiko [1 ]
机构
[1] Osaka Med Coll, Dept Ophthalmol, 2-7 Daigaku Cho, Takatsuki, Osaka 5698686, Japan
来源
CASE REPORTS IN OPHTHALMOLOGY | 2016年 / 7卷 / 03期
关键词
Transmuscular migration; Encircling silicone band; Scleral tunnel; Scleral buckling;
D O I
10.1159/000448512
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The migration of an encircling silicone band through a rectus muscle is a rare postoperative complication associated with scleral buckling surgery for retinal detachment. In this present study, we describe what we believe to be the first reported case of a patient who experienced postoperative migration of an encircling silicone band through the rectus muscle, despite the band being surgically secured to the sclera in a scleral tunnel. A 58-year-old man presented with a rhegmatogenous retinal detachment in his left eye. Pars plana vitrectomy was performed with the placement of an encircling silicone band, and the patient's retina was successfully reattached. One year postoperatively, the encircling band became exposed on the nasal side of the conjunctiva next to the limbus without any symptoms. Two weeks later, the exposed encircling band was surgically removed without any complications. The findings of this study show that even when an encircling silicone band is surgically secured around the eye, periodic and careful postoperative follow-up examinations should be performed to ensure no migration of the band. (C) 2016 The Author(s) Published by S. Karger AG, Basel
引用
收藏
页码:138 / 141
页数:4
相关论文
共 31 条
  • [1] Transmuscular migration of 240 silicone encircling band
    Kreis, A. J.
    Klainguti, G.
    Bovey, E. H.
    Wolfensberger, T. J.
    [J]. EYE, 2006, 20 (12) : 1456 - 1458
  • [2] Transmuscular migration of 240 silicone encircling band
    A J Kreis
    G Klainguti
    E H Bovey
    T J Wolfensberger
    [J]. Eye, 2006, 20 : 1456 - 1458
  • [3] Transmuscular migration of solid silicone band
    L T Tan
    N Thackare
    G Zohdy
    John Roberts-Harry
    [J]. Eye, 2007, 21 : 1013 - 1014
  • [4] Transmuscular migration of solid silicone band
    Tan, L. T.
    Thackare, N.
    Zohdy, G.
    Roberts-Harry, John
    [J]. EYE, 2007, 21 (07) : 1013 - 1014
  • [5] Transmuscular migration and straddling of the cornea by an encircling buckle
    Lopez, Mauricio A.
    Mateo, Carlos
    Corcotegui, Inigo
    Corcotegui, Borfa
    [J]. OPHTHALMIC SURGERY LASERS & IMAGING, 2007, 38 (05) : 402 - 403
  • [7] Secondary Glaucoma Associated with Encircling Scleral Buckle Migration into the Cornea
    Ozdek, Sengul
    Hasanreisoglu, Murat
    Adiguzel, Ufuk
    Aktas, Zeynep
    [J]. TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2016, 46 (01): : 44 - 46
  • [8] A NEW TANTALUM CLIP FOR SECURING A SILICONE ENCIRCLING BAND
    JOONDEPH, BC
    [J]. OPHTHALMIC SURGERY AND LASERS, 1992, 23 (10): : 711 - 711
  • [9] RETINAL-DETACHMENT AND TEMPORARY SILICONE ENCIRCLING BAND
    MALAGOLA, R
    PANNARALE, MR
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1994, 118 (03) : 400 - 401
  • [10] REACTION OF OCULAR TISSUES TO SCLERAL-IMPLANT AND ENCIRCLING MATERIAL - POLYAMIDE - SILICONE - POLYESTER
    WITSCHEL, H
    FAULBORN, J
    [J]. ALBRECHT VON GRAEFES ARCHIV FUR KLINISCHE UND EXPERIMENTELLE OPHTHALMOLOGIE, 1978, 206 (04): : 217 - 226