Repeatability of spatiotemporal, plantar pressure and force parameters during treadmill walking and running

被引:29
|
作者
Nuesch, Corina [1 ,2 ,3 ]
Overberg, Jan-Arie [1 ,4 ,5 ]
Schwameder, Hermann [5 ]
Pagenstert, Geert [1 ,3 ,6 ]
Mundermann, Annegret [1 ,2 ,3 ]
机构
[1] Univ Basel, Orthopaed & Traumatol Hosp, Basel, Switzerland
[2] Univ Basel, Dept Biomed Engn, Basel, Switzerland
[3] Univ Basel, Dept Clin Res, Basel, Switzerland
[4] Med Fitness Team, Basel, Switzerland
[5] Univ Salzburg, Dept Sport Sci & Kinesiol, Hallein Rif, Austria
[6] Merian Iselin Hosp Basel, Clarahof Clin Orthopaed Surg, Basel, Switzerland
关键词
Repeatability; Gait; Running; Treadmill; Pressure; Force; INSTRUMENTED TREADMILL; PARKINSONS-DISEASE; MULTIPLE-SCLEROSIS; GAIT PARAMETERS; LOWER-EXTREMITY; RELIABILITY; SPEED; SYSTEM; OSTEOARTHRITIS; PEOPLE;
D O I
10.1016/j.gaitpost.2018.03.017
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: Instrumented treadmills with integrated pressure mats measure spatiotemporal, pressure and force parameters and are often used to investigate changes in gait patterns due to injury or rehabilitation. Research question: What is the within- and between-day repeatability of such an instrumented treadmill for spatiotemporal parameters, peak pressures and forces during walking and running? Methods: Treadmill gait and running analysis were performed at 5.0, 6.5, and 9.0 km/h in 33 healthy adults (age: 31.6 +/- 7.4 years; body mass index: 23.8 +/- 3.2 kg/m(2)) once on day 1 and twice on day 7. For all three speeds, intraclass correlation coefficents (ICC) and smallest detectable differences (SDC) corresponding to 95% limits of agreement were calculated for spatiotemporal parameters and peak pressures and forces in the heel, midfoot, and forefoot regions. Results: All spatiotemporal parameters and peak forces in the heel, midfoot, and forefoot regions showed a good within- and between-day repeatability (ICCs > 0.878) for all gait speeds with within- day repeatability being generally higher. For peak pressures, only the heel and forefoot regions but not the midfoot region, showed good repeatability (ICC > 0.9) at all gait speeds. SDCs ranged from 1.5 to 2.5 degrees for foot rotation, 4.4 to 6.6 cm for stride length, 0.7 to 2.5% for length of stance phases, and 2.8 to 9.2 N/cm(2) for peak pressures in all foot regions. For walking, SDCs of peak forces in the heel, midfoot and forefoot regions were below 60 N, and for running below 135 N. Significance: Except for peak pressures in the midfoot, spatiotemporal and kinetic gait parameters during walking and running showed a good within- and between-day repeatability. Hence, the investigated treadmill is suitable to analyze gait patterns and changes in gait patterns due to interventions.
引用
收藏
页码:117 / 123
页数:7
相关论文
共 50 条
  • [1] Correlation between treadmill acceleration, plantar pressure, and ground reaction force during running
    Alex, J. Y. Lee
    Chou, Jia-Hao
    Liu, Ying-Fang
    Lin, Wei-Hsiu
    Shiang, Tzyy-Yuang
    [J]. ENGINEERING OF SPORT 7, VOL 1, 2008, : 281 - +
  • [2] Repeatability of plantar pressure assessment during barefoot walking in people with stroke
    A. Rogers
    S. C. Morrison
    T. Gorst
    J. Paton
    J. Freeman
    J. Marsden
    M. C. Cramp
    [J]. Journal of Foot and Ankle Research, 13
  • [3] Repeatability of plantar pressure assessment during barefoot walking in people with stroke
    Rogers, A.
    Morrison, S. C.
    Gorst, T.
    Paton, J.
    Freeman, J.
    Marsden, J.
    Cramp, M. C.
    [J]. JOURNAL OF FOOT AND ANKLE RESEARCH, 2020, 13 (01)
  • [4] Determining the centre of pressure during walking and running using an instrumented treadmill
    Verkerke, GJ
    Hof, AL
    Zijlstra, W
    Ament, W
    Rakhorst, G
    [J]. JOURNAL OF BIOMECHANICS, 2005, 38 (09) : 1881 - 1885
  • [5] The Effect Of Two Custom Molded Orthotics On Plantar Pressure During Treadmill Walking
    Hodgson, Brad T.
    Tis, Laurie L.
    Cobb, Steven C.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 : S214 - S214
  • [6] Performance determinants, running energetics and spatiotemporal gait parameters during a treadmill ultramarathon
    Howe, Christopher C. F.
    Swann, Nicola
    Spendiff, Owen
    Kosciuk, Anna
    Pummell, Elizabeth K. L.
    Moir, Hannah J.
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2021, 121 (06) : 1759 - 1771
  • [7] Performance determinants, running energetics and spatiotemporal gait parameters during a treadmill ultramarathon
    Christopher C. F. Howe
    Nicola Swann
    Owen Spendiff
    Anna Kosciuk
    Elizabeth K. L. Pummell
    Hannah J. Moir
    [J]. European Journal of Applied Physiology, 2021, 121 : 1759 - 1771
  • [8] Spatiotemporal Parameters of Gait During Treadmill and Overground Walking in Parkinson's Disease
    Bello, Olalla
    Sanchez, Jose Andres
    Vazquez-Santos, Cristina
    Fernandez-Del-Olmo, Miguel
    [J]. JOURNAL OF PARKINSONS DISEASE, 2014, 4 (01) : 33 - 36
  • [9] Comparison of plantar loads during treadmill and overground running
    Hong, Youlian
    Wang, Lin
    Li, Jing Xian
    Zhou, Ji He
    [J]. JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2012, 15 (06) : 554 - 560
  • [10] The effect of foot type on in-shoe plantar pressure during walking and running
    Chuckpaiwong, Bavornrit
    Nunley, James A.
    Mall, Nathan A.
    Queen, Robin M.
    [J]. GAIT & POSTURE, 2008, 28 (03) : 405 - 411