EVALUATION OF ACCURACY IN THE ALCHEMI METHOD

被引:8
|
作者
NAKATA, Y
TADAKI, T
SHIMIZU, K
机构
[1] The Institute of Scientific and Industrial Research, Osaka University, Ibaraki, Osaka, 567, 8-1, Mihoga-oka
关键词
D O I
10.1016/0304-3991(91)90184-8
中图分类号
TH742 [显微镜];
学科分类号
摘要
An ALCHEMI measurement has been carried out to determine the crystallographic site of Co atoms in a Ti48.5Ni48.5Co3 shape memory alloy. The accuracy of ALCHEMI can be evaluated in terms of the r value, which is denoted by a difference in intensity between incident electron beams along Ti and Ni planes. In the present paper, the r value has been calculated as a function of crystal thickness, diffraction condition and accelerating voltage. It was thus found that the r value calculated without consideration of absorption effects did not explain experimental results. However, taking account of the absorption effects, it was quantitatively in good agreement with experimental results. It was also found that the r value increased with increasing accelerating voltage, the maximum value for 1 MV being about 2.5 times larger than that for 100 kV.
引用
收藏
页码:72 / 80
页数:9
相关论文
共 50 条
  • [1] Accuracy Evaluation of the Huygens Subgridding Method
    Gradoni, G.
    Primiani, V. Mariani
    Moglie, F.
    PIERS 2009 MOSCOW VOLS I AND II, PROCEEDINGS, 2009, : 1338 - 1343
  • [2] METHOD FOR EVALUATION OF ACCURACY OF AXIS OF ROTATION
    NYPAN, LJ
    MICROTECNIC, 1972, 26 (04): : 232 - &
  • [3] Evaluation method of star sensor dynamic accuracy
    Ren, Pingchuan
    Zhou, Qi
    Jin, He
    Song, Qingzheng
    Miao, Pengfei
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2022, 51 (03):
  • [4] A new method for the accuracy evaluation of a manufactured piece
    Oniga, E. V.
    Cardei, M.
    MODERN TECHNOLOGIES IN INDUSTRIAL ENGINEERING (MODTECH2015), 2015, 95
  • [5] A PRACTICAL EVALUATION OF ACCURACY BY SDI CHART METHOD
    NIWA, M
    NOBUTAKA, I
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1981, 19 (08): : 785 - 785
  • [6] Cooperative Measurement Accuracy Evaluation Method and Software
    Ren, Yu
    Zhang, Feng
    Liu, Fangfang
    Hu, Xiaolei
    Long, Changyu
    Fu, Yunxia
    OPTICAL METROLOGY AND INSPECTION FOR INDUSTRIAL APPLICATIONS VIII, 2021, 11899
  • [7] EELS ALCHEMI revisited
    Brydson, R
    Brown, AP
    McBride, S
    Calvert, C
    Bell, AJ
    ELECTRON MICROSCOPY AND ANALYSIS 2003, 2004, (179): : 295 - 298
  • [8] ADVANCES IN ALCHEMI ANALYSIS
    TURNER, PS
    WHITE, TJ
    OCONNOR, AJ
    ROSSOUW, CJ
    JOURNAL OF MICROSCOPY-OXFORD, 1991, 162 : 369 - 378
  • [9] A high-accuracy system model and accuracy evaluation method for transfer alignment
    Yang, Jie
    Wang, Xinlong
    Wang, Bin
    Hu, Xiaodong
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2024, 35 (07)
  • [10] Estimation of site occupancy error due to statistical noise for the ratio ALCHEMI method
    Hao, YL
    Yang, R
    Cui, YY
    Li, D
    SCRIPTA MATERIALIA, 1999, 41 (12) : 1305 - 1310