STANDARDIZED COLOR-CODED MAPS FOR CORNEAL TOPOGRAPHY

被引:1
|
作者
WILSON, SE [1 ]
KLYCE, SD [1 ]
HUSSEINI, ZM [1 ]
机构
[1] LOUISIANA STATE UNIV,MED CTR,SCH MED,MED CTR,CTR EYE,NEW ORLEANS,LA 70112
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Modern videokeratoscopy is useful in assessing corneal shape. The purpose of this study is to compare color-coded topographic maps using standardized scales with 1.0- and 1.5-diopter (D) intervals. The authors assessed the use of the two scales for detecting clinically relevant features of corneal topography such as regular astigmatism, irregular astigmatism, early keratoconus, and contact lens-induced corneal warpage. Methods: A total of 50 normal corneas, 50 corneas with contact lenses, 50 that had keratoconus (25 early to moderate and 25 advanced), 50 that had penetrating keratoplasty, 20 that had extracapsular cataract surgery, 17 that had excimer laser photorefractive keratectomy for myopia, 1 0 that had radial keratotomy, 3 that had aphakic epikeratophakia, and 2 that had myopic epikeratophakia were analyzed with a corneal topographic analysis system. Color-coded maps with 1.0-D intervals (Maguire/Waring scale) and 1.5-D intervals (Klyce/Wilson scale) were compared. Results: There were no topographic characteristics that were not appreciated with either scale for corneas with dioptric powers that fell within their ranges. Conversely, for corneas that had powers outside the range of the 1.0-diopter scale, but within the range of the 1.5-diopter scale, the former produced a map in which the flattest or steepest areas were artifactually smoothed. Conclusions: This study suggests that the Klyce/Wilson scale (constant, 1.5-D intervals) provides the best combination of sensitivity for detection of clinically significant topographic features and the widest range of coverage of powers that are found on a variety of normal, pathologic, and surgically altered corneas. The adoption of the Klyce/Wilson scale by all manufacturers of corneal topographic instruments as a primary standard will facilitate communication and will make the interpretation of corneal topography easier for both the expert and the novice.
引用
收藏
页码:1723 / 1727
页数:5
相关论文
共 50 条
  • [1] STANDARDIZED COLOR-CODED MAPS FOR CORNEAL TOPOGRAPHY
    HUSSEINI, ZM
    WILSON, SE
    KLYCE, SD
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 1252 - 1252
  • [2] STANDARDIZED COLOR-CODED CORNEAL MAPS
    SIEGEL, IM
    [J]. OPHTHALMOLOGY, 1994, 101 (05) : 795 - 795
  • [3] STANDARDIZED COLOR-CODED CORNEAL MAPS - REPLY
    WILSON, SE
    KLYCE, SD
    [J]. OPHTHALMOLOGY, 1994, 101 (05) : 796 - 797
  • [4] Standardized color-coded scales for anterior and posterior elevation maps of scanning slit corneal topography
    Tanabe, T
    Oshika, T
    Tomidokoro, A
    Amano, S
    Tanaka, S
    Kuroda, T
    Maeda, N
    Tokunaga, T
    Miyata, K
    [J]. OPHTHALMOLOGY, 2002, 109 (07) : 1298 - 1302
  • [5] Color-coded perimetric probability maps; A clinical study
    Asman, P
    [J]. VISION RESEARCH, 1996, 36 : 2214 - 2214
  • [6] COLOR-CODED
    WILLIAMSON, M
    [J]. NATURE, 1993, 366 (6452) : 199 - 199
  • [7] Diffusion Tensor Imaging Color-Coded Maps: An Alternative to Tractography
    Schneider, Julia R.
    Raval, Ami B.
    Black, Karen
    Schulder, Michael
    [J]. STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2021, 99 (04) : 295 - 304
  • [8] Color-coded visualization of magnetic resonance imaging multiparametric maps
    Kather, Jakob Nikolas
    Weidner, Anja
    Attenberger, Ulrike
    Bukschat, Yannick
    Weis, Cleo-Aron
    Weis, Meike
    Schad, Lothar R.
    Zoellner, Frank Gerrit
    [J]. SCIENTIFIC REPORTS, 2017, 7
  • [9] Color-coded visualization of magnetic resonance imaging multiparametric maps
    Jakob Nikolas Kather
    Anja Weidner
    Ulrike Attenberger
    Yannick Bukschat
    Cleo-Aron Weis
    Meike Weis
    Lothar R. Schad
    Frank Gerrit Zöllner
    [J]. Scientific Reports, 7
  • [10] Color-coded standing
    Spann, GA