QUANTITATIVE INFRARED-ANALYSIS OF BOROPHOSPHOSILICATE FILMS USING MULTIVARIATE STATISTICAL-METHODS

被引:81
|
作者
HAALAND, DM
机构
[1] Sandia Natl Lab, Albuquerque, NM,, USA, Sandia Natl Lab, Albuquerque, NM, USA
关键词
MATHEMATICAL TECHNIQUES - Least Squares Approximations - SPECTROSCOPY; INFRARED - Applications - STATISTICAL METHODS;
D O I
10.1021/ac00162a022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Infrared (IR) spectroscopy can serve as a rapid method for the quantitative analysis of borophosphosilicate glass (BPSG) films on Si wafers for the microelectronics industry. The advantages of using statistically designed calibration sets are emphasized. Classical least-squares (CLS), partial least-squares (PLS), and principal component regression (PCR) methods are all found to provide improved precision over traditional peak-height measurements. The quantitative results from spectral measurements taken in transmission mode at both 0 degree and 60 degree incident angles were also compared.
引用
收藏
页码:1208 / 1217
页数:10
相关论文