BIOMECHANICAL REMODELING OF BIODEGRADABLE SMALL-DIAMETER VASCULAR GRAFTS IN SITU

被引:4
|
作者
Glushkova, T. V. [1 ]
Sevostyanova, V. V. [1 ]
Antonova, L. V. [1 ]
Klyshnikov, K. Yu. [1 ]
Ovcharenko, E. A. [1 ]
Sergeeva, E. A. [1 ]
Vasyukov, G. Yu. [1 ]
Seifalian, A. M. [2 ,3 ]
Barbarash, L. S. [1 ]
机构
[1] Fed State Budgetary Sci Inst, Res Inst Complex Issues Cardiovasc Dis, Kemerovo, Russia
[2] UCL, UCL Div Surg & Intervent Sci, Ctr Nanotechnol & Regenerat Med, London, England
[3] NanoRegMed Ltd, London, England
来源
关键词
polycaprolactone; polyhydroxybutyrate/valerate; vascular endothelial growth factor; vascular graft; electrospinning;
D O I
10.15825/1995-1191-2016-2-99-109
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Aim: to evaluate the biomechanical remodeling of polymer grafts modified with vascular endothelial growth factor (VEGF) after implantation into rat abdominal aorta. Materials and methods. Vascular grafts of 2 mm diameter were fabricated by electrospinning from polycaprolactone (PCL) and a mixture of poly (3-hydroxybutyrate-co-3-hydroxyvalerate) and PCL. The grafts were modified with VEGF by biphasic electrospinning. Morphology of the grafts was assessed by scanning electron microscopy. Physico-mechanical properties of PCL and PHBV/PCL grafts were estimated using uniaxial tensile test and physiological circulating system equipped with state-of-the-art ultrasound vascular wall tracking system. Physico-mechanical testing of PCL/VEGF and PHBV/PCL/VEGF was performed before and after implantation into rat abdominal aorta for 6 months. The modeling of coronary artery bypass grafting (CABG) was performed by finite element analysis for modified grafts. Results. Durability of PCL and PHBV/PCL grafts did not differ from that of human internal mammary artery; however, elasticity and stiffness of these grafts were higher compared to internal mammary artery. Viscoelastic properties of the grafts were comparable to those of native blood vessels. Modification of the grafts with VEGF reduced material stiffness. Six months postimplantation, PCL/VEGF and PHBV/PCL/VEGF were integrated with aortic tissue that induced changes in the physico-mechanical properties of the grafts similar to the native vessel. Biomechanical modeling confirmed the functioning of modified grafts in bypass position for CABG. Conclusion. PCL/VEGF and PHBV/PCL/VEGF grafts have satisfactory physico-mechanical properties and can be potentially used in the reconstruction of blood vessels.
引用
收藏
页码:99 / 109
页数:11
相关论文
共 50 条
  • [1] Strategies and Techniques to Enhance the In Situ Endothelialization of Small-Diameter Biodegradable Polymeric Vascular Grafts
    Melchiorri, Anthony J.
    Hibino, Narutoshi
    Fisher, John P.
    [J]. TISSUE ENGINEERING PART B-REVIEWS, 2013, 19 (04) : 292 - 307
  • [2] POLYPROPYLENE SMALL-DIAMETER VASCULAR GRAFTS
    GREISLER, HP
    TATTERSALL, CW
    HENDERSON, SC
    CABUSAO, EA
    GARFIELD, JD
    KIM, DU
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1992, 26 (10): : 1383 - 1394
  • [3] Development of Small-Diameter Vascular Grafts
    Xinwen Wang
    Peter Lin
    Qizhi Yao
    Changyi Chen
    [J]. World Journal of Surgery, 2007, 31 : 682 - 689
  • [4] Development of small-diameter vascular grafts
    Wang, Xinwen
    Lin, Peter
    Yao, Qizhi
    Chen, Changyi
    [J]. WORLD JOURNAL OF SURGERY, 2007, 31 (04) : 682 - 689
  • [5] RESULTS OF PRECLINICAL TRIALS IN A SHEEP MODEL OF BIODEGRADABLE SMALL-DIAMETER VASCULAR GRAFTS
    Antonova, L., V
    Krivkina, E. O.
    Khanova, M. Yu
    Velikanova, E. A.
    Matveeva, V. G.
    Mironov, A., V
    Shabaev, A. R.
    Senokosova, E. A.
    Glushkova, T., V
    Sinitsky, M. Yu
    Mukhamadiyarov, R. A.
    Barbarash, L. S.
    [J]. VESTNIK TRANSPLANTOLOGII I ISKUSSTVENNYH ORGANOV, 2022, 24 (03): : 80 - 93
  • [6] Bioscaffolds development for small-diameter vascular grafts
    Zhao, Nan
    Zhu, Donghui
    [J]. INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2013, 12 (02) : 113 - 129
  • [7] Extracellular Matrix for Small-Diameter Vascular Grafts
    Kimicata, Megan
    Swamykumar, Prateek
    Fisher, John P.
    [J]. TISSUE ENGINEERING PART A, 2020, 26 (23-24) : 1388 - 1401
  • [8] Tissue engineered small-diameter vascular grafts
    Schmedlen, RH
    Elbjeirami, WM
    Gobin, AS
    West, JL
    [J]. CLINICS IN PLASTIC SURGERY, 2003, 30 (04) : 507 - +
  • [9] Application of decellularized vascular matrix in small-diameter vascular grafts
    Li, Yuanming
    Zhou, Ying
    Qiao, Weihua
    Shi, Jiawei
    Qiu, Xuefeng
    Dong, Nianguo
    [J]. FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 10
  • [10] Tissue engineering of recellularized small-diameter vascular grafts
    Borschel, GH
    Huang, YC
    Calve, S
    Arruda, EM
    Lynch, JB
    Dow, DE
    Kuzon, WM
    Dennis, RG
    Brown, DL
    [J]. TISSUE ENGINEERING, 2005, 11 (5-6): : 778 - 786