EXPERIMENTAL AND NUMERICAL ANALYSIS OF FLOW FIELD AND VENTILATION PERFORMANCE IN A TRAFFIC TUNNEL VENTILATED BY AXIAL FANS

被引:3
|
作者
Sekularac, Milan [1 ]
Jankovic, Novica [2 ]
机构
[1] Univ Montenegro, Fac Mech Engn, Lab Fluid Mech & Energy Proc, Podgorica, Montenegro
[2] Univ Belgrade, Fac Mech Engn, Hydraul Machinery & Energy Syst Dept, Belgrade, Serbia
关键词
ventilation flows; tunnels; axial ducted fans; turbulence; numerical boundary conditions; CFD;
D O I
10.2298/TAM171201010S
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
To investigate air flow in longitudinally ventilated traffic tunnels, a scaled model of a typical road-traffic tunnel with an appropriate ventilation system based on axial ducted fans, is designed and built in the Lab. The focus of this paper is the airflow in a bi-directional traffic, two-lane tunnel. At the scale ratio of approx. 1:20, at 20.52 m length it represents approximate to 400 m of a real-scale tunnel. The model consists of two parallel tunnel tubes, where the main tunnel (with a hydraulic diameter of D-h1 approximate to 0.4 m has the geometry of a scaled road traffic-tunnel. The second tunnel (D-h2 approximate to 0.16 m) has a smaller size and is circular in cross-section, used only to simulate airflow towards an evacuation tunnel tube. Thus the two tunnels are connected by the evacuation passages, equipped with adjustable escape doors. By a combination of experimental and numerical work, the air flow-field and the performance of the ventilation system are investigated. The velocity field and its turbulence properties exiting the fans were determined experimentally using hot-wire anemometry. These data were further processed to be used in the tunnel flow computations by CFD. The efficiency of momentum transfer (eta(i), Kempf factor) of the longitudinal tunnel ventilation is determined. The effect that the imposed boundary conditions and the level of their detail, have within a CFD computation of tunnel airflow, with respect to accuracy, velocity distribution and computed eta(i), Finally a traffic-loaded (traffic "jam'') case of flow is studied through experiment and CFD. The difficulty in assessing the required thrust of the plant in traffic-jam tunnel conditions is discussed, and the ventilation efficiency is estimated. Based on later results, the two limiting shapes of axial velocity distribution with respect to height above the road, in this type of tunnel and traffic, are estimated. The last result can be used as a realistic boundary condition (as inlet b.c. and/or initial condition) for numerical studies of flow and fire scenarios in such tunnels with the traffic load critical for design.
引用
收藏
页码:151 / 165
页数:15
相关论文
共 50 条
  • [1] Exit flow field and performance of axial flow fans
    Yen, SC
    Lin, FKT
    [J]. JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (02): : 332 - 340
  • [2] Numerical study the performance of jet fans in utility tunnel ventilation
    Bai, Zhenpeng
    Li, Yanfeng
    Li, Junmei
    [J]. 2019 INTERNATIONAL CONFERENCE ON INTELLIGENT TRANSPORTATION, BIG DATA & SMART CITY (ICITBS), 2019, : 36 - 38
  • [3] REVERSING OF AXIAL FLOW FANS FOR VENTILATION
    Cyrus, Vaclav
    Pelnar, Jiri
    Cyrus, Jan
    [J]. PROCEEDINGS OF THE ASME TURBO EXPO 2011, VOL 4, 2012, : 471 - 482
  • [4] ANALYSIS OF THE FLOW FIELD IN OPTIMIZED AXIAL FANS
    Bamberger, Konrad
    Carolus, Thomas
    [J]. ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2015, VOL 1, 2015,
  • [5] A numerical investigation into the performance of two types of jet fans in ventilation of an urban tunnel under traffic jam condition
    Eftekharian, Esmaeel
    Dastan, Alireza
    Abouali, Omid
    Meigolinedjad, Javad
    Ahmadi, Goodarz
    [J]. TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2014, 44 : 56 - 67
  • [6] PERFORMANCE OF SEVERAL AXIAL-FLOW FANS FOR GRAIN BIN VENTILATION
    METZGER, JF
    TERRY, PD
    MUIR, WE
    [J]. CANADIAN AGRICULTURAL ENGINEERING, 1981, 23 (01): : 11 - 16
  • [7] Experimental and numerical studies on new spray axial-flow fans
    [J]. Li, J.-Y. (jyli@mail.xjtu.edu.cn), 1600, Science Press (34):
  • [8] EXPERIMENTAL DETERMINATION OF TUNNEL VENTILATION AXIAL DUCTED FAN PERFORMANCE
    Sekularac, Milan B.
    [J]. THERMAL SCIENCE, 2016, 20 (01): : 209 - 221
  • [9] PERFORMANCE OF SEVERAL AXIAL-FLOW FANS FOR GRAIN BIN VENTILATION.
    Metzger, J.F.
    Terry, P.D.
    Muir, W.E.
    [J]. Canadian Agricultural Engineering, 1600, 23 (01): : 11 - 16
  • [10] NUMERICAL AND EXPERIMENTAL ANALYSES FOR THE AERODYNAMIC DESIGN OF HIGH PERFORMANCE COUNTER-ROTATING AXIAL FLOW FANS
    Cho, Leesang
    Choi, Hyunmin
    Lee, Seawook
    Cho, Jinsoo
    [J]. FEDSM2009, VOL 2, 2009, : 231 - 244