INSTABILITY AND WEAR OF TOTAL HIP PROSTHESES DETERMINED WITH ROENTGEN STEREOPHOTOGRAMMETRY

被引:54
|
作者
BALDURSSON, H
EGUND, N
HANSSON, LI
SELVIK, G
机构
[1] UNIV LUND HOSP,DEPT ORTHOPAED SURG,S-22185 LUND,SWEDEN
[2] UNIV LUND HOSP,DEPT DIAGNOST RADIOL,S-22185 LUND,SWEDEN
[3] UNIV LUND,DEPT ANAT,S-22101 LUND,SWEDEN
关键词
D O I
10.1007/BF00389695
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
引用
收藏
页码:257 / 263
页数:7
相关论文
共 50 条
  • [1] MIGRATION OF THE ACETABULAR SOCKET AFTER TOTAL HIP-REPLACEMENT DETERMINED BY ROENTGEN STEREOPHOTOGRAMMETRY
    BALDURSSON, H
    HANSSON, LI
    OLSSON, TH
    SELVIK, G
    ACTA ORTHOPAEDICA SCANDINAVICA, 1980, 51 (03): : 535 - 540
  • [2] INSTABILITY OF TOTAL HIP PROSTHESES AT ROTATIONAL STRESS - A ROENTGEN STEREOPHOTOGRAMMETRIC STUDY
    MJOBERG, B
    HANSSON, LI
    SELVIK, G
    ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (05): : 504 - 506
  • [3] INSTABILITY OF TOTAL HIP PROSTHESES AT ROTATIONAL STRESS - A ROENTGEN STEREOPHOTOGRAMMETRIC STUDY
    MJOBERG, B
    HANSSON, LI
    SELVIK, G
    ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (06): : 675 - 675
  • [4] INSTABILITY, MIGRATION AND LAXITY OF TOTAL HIP PROSTHESES - A ROENTGEN STEREOPHOTOGRAMMETRIC STUDY
    MJOBERG, B
    HANSSON, LI
    SELVIK, G
    ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (02): : 141 - 145
  • [5] Induction of genomic instability by metal wear debris from total hip prostheses
    Schenck, FJ
    Case, CP
    Mothersill, C
    MOLECULAR BIOLOGY OF THE CELL, 2001, 12 : 358A - 358A
  • [6] DETERMINATION OF CHANGES IN POSITION OF KNEE PROSTHESES BY ROENTGEN STEREOPHOTOGRAMMETRY
    EGUND, N
    JONSSON, G
    LINDSTRAND, A
    SELVIK, G
    ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (04): : 447 - 447
  • [7] Polyethylene wear in total hip prostheses: the influence of direction of linear wear on volumetric wear determined from radiographic data
    Kosak, R
    Antolic, V
    Pavlovcic, V
    Kralj-Iglic, V
    Milosev, I
    Vidmar, G
    Iglic, A
    SKELETAL RADIOLOGY, 2003, 32 (12) : 679 - 686
  • [8] Polyethylene wear in total hip prostheses: the influence of direction of linear wear on volumetric wear determined from radiographic data
    R. Košak
    V. Antolič
    V. Pavlovčič
    V. Kralj-Iglič
    I. Milošev
    G. Vidmar
    A. Iglič
    Skeletal Radiology, 2003, 32 : 679 - 686
  • [9] OPERATIVE GROWTH ARREST DETERMINED BY ROENTGEN STEREOPHOTOGRAMMETRY
    BYLANDER, B
    EGUND, N
    HANSSON, LI
    SELVIK, G
    ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (04): : 440 - 441
  • [10] STUDY OF WEAR RESISTANT MATERIALS FOR TOTAL HIP PROSTHESES
    SHEN, C
    DUMBLETO.J
    MILLER, E
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1974, A 56 (04): : 847 - 847