COMPARISON OF OSCILLOMETRIC AND INTRAARTERIAL BLOOD-PRESSURE AND PULSE MEASUREMENT

被引:11
|
作者
RITHALIA, SVS [1 ]
EDWARDS, D [1 ]
机构
[1] MANCHESTER ROYAL INFIRM,INTENS THERAPY UNIT,MANCHESTER M13 9WL,LANCS,ENGLAND
关键词
D O I
10.3109/03091909409030249
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Non-invasive oscillometric blood pressure and pulse measured by an Omron HEM-703CP monitor were compared with arterial values obtained from direct measurements of the radial artery. An excellent correlation and agreement was found between the two methods (systolic r = 0.99; diastolic r = 0.97; pulse r = 0.99), although (here was some variability among individual subjects. The range of difference between them was 0 to 10 mmHg for systolic and - 6 to + 5 mmHg for diastolic pressures. When tested on the bench wing the Metron QA-1280 non-invasive blood pressure analyser the HEM-703CP monitor rarely exhibited errors exceeding 2-3 mmHg over a measurement range of 50-200 mmHg.
引用
收藏
页码:179 / 181
页数:3
相关论文
共 50 条
  • [1] COMPARISON OF INTRAARTERIAL AND AUTOMATED OSCILLOMETRIC BLOOD-PRESSURE MEASUREMENT METHODS IN POSTOPERATIVE HYPERTENSIVE PATIENTS
    LOUBSER, PG
    MEDICAL INSTRUMENTATION, 1986, 20 (05): : 255 - 259
  • [2] Personalization of the Oscillometric Blood-Pressure Measurement
    Nagy, P.
    Jobbagy, A.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 2, 2019, 68 (02): : 885 - 888
  • [3] MEASUREMENT OF BLOOD-PRESSURE IN OBESE PERSONS - COMPARISON OF INTRAARTERIAL AND FINGER ARTERIAL BLOOD-PRESSURE (FINAPRES)
    PONCELET, P
    DURAND, P
    LECHANTRE, R
    MOUNIERVEHIER, C
    FOUQUOIRE, B
    PETETIN, N
    CARRE, A
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1992, 85 (08): : 1165 - 1168
  • [4] SIMULTANEOUS COMPARISON OF KOROTKOFF AND OSCILLOMETRIC METHODS FOR AMBULATORY BLOOD-PRESSURE MEASUREMENT
    BRIGDEN, GS
    CASHMAN, PM
    BROADHURST, P
    LAHIRI, A
    RAFTERY, EB
    JOURNAL OF HYPERTENSION, 1989, 7 : S354 - S355
  • [5] A METHOD FOR INTRAARTERIAL MEASUREMENT OF BLOOD-PRESSURE IN CATTLE
    MULLER, M
    GOETZE, L
    DEUTSCHE TIERARZTLICHE WOCHENSCHRIFT, 1987, 94 (09): : 517 - 518
  • [6] COMPARISON OF BLOOD-PRESSURE MEASUREMENTS BY SEMIAUTOMATIC CUFF-OSCILLOMETRIC AND SPHYGMOMANOMETRIC MICROPHONE METHODS WITH INTRAARTERIAL VALUES
    KLAUS, D
    WETZCHEWALD, D
    SAUL, F
    OBERMEIER, G
    LAMBERS, F
    NIEREN-UND HOCHDRUCKKRANKHEITEN, 1991, 20 (04) : 160 - 169
  • [7] THE EFFECT OF SLEEVED ARMS ON OSCILLOMETRIC BLOOD-PRESSURE MEASUREMENT
    HOLLEMAN, DR
    WESTMAN, EC
    MCCRORY, DC
    SIMEL, DL
    JOURNAL OF GENERAL INTERNAL MEDICINE, 1993, 8 (06) : 325 - 326
  • [9] STANDARD ALGORITHM OF BLOOD-PRESSURE MEASUREMENT BY THE OSCILLOMETRIC METHOD
    YAMAKOSHI, K
    TANAKA, S
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1993, 31 (02) : 204 - 204
  • [10] BLOOD-PRESSURE MEASUREMENT USING OSCILLOMETRIC FINGER CUFFS
    OBRIEN, E
    ATKINS, N
    ANAESTHESIA, 1995, 50 (08) : 743 - 744