SPATIAL-RESOLUTION ACROSS THE MACAQUE RETINA

被引:80
|
作者
MERIGAN, WH [1 ]
KATZ, LM [1 ]
机构
[1] UNIV ROCHESTER,MED CTR,CTR VISUAL SCI,ROCHESTER,NY 14642
关键词
Acuity Sampling density Cones Ganglion cells Macaque monkey;
D O I
10.1016/0042-6989(90)90107-V
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Grating acuity was measured as a function of eccentricity from the fovea in two macaques. A vertical-horizontal orientation discrimination was used to determine acuity, and the retinal locus of the test grating was controlled by training them to fixate a spot placed at various distances from the stimulus. Their head was fixed in place and fixation was monitored with a scleral search coil. The acuity of monkeys across the retina was similar to that previously measured in human subjects, reaching a peak of about 38 c/deg at the fovea, and decreasing about 10-fold by 30 deg eccentricity. Acuity was slightly higher in the temporal than in the nasal visual field. The shape of the acuity-eccentricity function suggested a dependence on cone density near the fovea, and on the density of P ganglion cells at eccentricities beyond 10 deg. Existing physiological data suggest the possibility that macaque acuity may also be limited in part by spatial averaging across the receptive field of retinal ganglion cells. © 1990.
引用
收藏
页码:985 / 991
页数:7
相关论文
共 50 条
  • [1] THE DEVELOPMENT OF SPATIAL-RESOLUTION IN THE PIGEON RETINA
    BAGNOLI, P
    PORCIATTI, V
    BARSELLOTTI, R
    [J]. PERCEPTION, 1983, 12 (01) : A20 - A21
  • [2] THE SPATIAL-RESOLUTION CAPACITY OF HUMAN FOVEAL RETINA
    HIRSCH, J
    CURCIO, CA
    [J]. VISION RESEARCH, 1989, 29 (09) : 1095 - &
  • [3] DYNAMIC SPATIAL-RESOLUTION
    GODDARD, BA
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (06): : 1144 - 1150
  • [4] SPATIAL-RESOLUTION OF THE GALAGO
    LANGSTON, A
    CASAGRANDE, VA
    FOX, R
    [J]. VISION RESEARCH, 1986, 26 (05) : 791 - 796
  • [5] ON THE SPATIAL-RESOLUTION OF CLINICAL THERMOMETERS
    GERIG, LH
    SZANTO, J
    RAAPHORST, GP
    [J]. MEDICAL PHYSICS, 1992, 19 (03) : 679 - 684
  • [6] SPATIAL-RESOLUTION IN DIGITAL MAMMOGRAPHY
    KARSSEMEIJER, N
    FRIELING, JTM
    HENDRIKS, JHCL
    [J]. INVESTIGATIVE RADIOLOGY, 1993, 28 (05) : 413 - 419
  • [7] THE LIMITS OF SPATIAL-RESOLUTION IN PIXE
    LEGGE, GJF
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1987, 22 (1-3): : 115 - 120
  • [8] HIGH SPATIAL-RESOLUTION MICROANALYSIS
    NICHOLLS, AW
    BOVEY, PE
    [J]. JOURNAL OF ELECTRON MICROSCOPY TECHNIQUE, 1987, 7 (02): : 141 - 141
  • [9] SPATIAL-RESOLUTION OF THERMOGRAPHIC CAMERAS
    STEKETEE, J
    [J]. BIBLIOTHECA RADIOLOGICA, 1975, (06) : 25 - 32
  • [10] FOURIER SPECTROMETRY WITH SPATIAL-RESOLUTION
    DUBKOV, VI
    [J]. OPTIKA I SPEKTROSKOPIYA, 1984, 57 (01): : 152 - 154