Accuracy and Safety of Percutaneous Lumbosacral Pedicle Screw Placement Using Dual-Planar Intraoperative Fluoroscopy

被引:9
|
作者
Dunn, Conor [1 ]
Faloon, Michael [1 ]
Milman, Edward [1 ]
Pourtaheri, Sina [2 ]
Sinah, Kumar [1 ]
Hwang, Ki [1 ]
Emami, Arash [1 ]
机构
[1] Seton Hall Univ, Sch Hlth & Med Sci, Wayne, NJ 07470 USA
[2] Univ Calif Los Angeles, Dept Orthopaed Surg, Los Angeles, CA USA
关键词
Minimally invasive surgical procedures; Lumbosacral region; Pedicle screws; Fluoroscopy;
D O I
10.4184/asj.2018.12.2.238
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Study Design: Retrospective case series with prospective arm. Purpose: To assess the safety and accuracy of percutaneous lumbosacral pedicle screw placement (PLPSP) in the lumbosacral spine using intraoperative dual-planar fluoroscopy (DPF). Overview of Literature: There are several techniques available for achieving consistent, safe, and accurate results with PLPSP. There is a paucity of literature describing the beneficial operative, economic, and clinical outcomes of DPF, the most readily accessible image guidance system. Methods: From 2004 to 2014, 451 consecutive patients underwent PLPSP using DPF, for a total of 2,345 screw placement. The results of prospectively obtained postoperative computed tomography (CT) examinations of an additional 41 consecutive patients were compared with the results of 104 CT examinations obtained postoperatively due to clinical symptomatology; these results were interpreted by three reviewers. The rates of revision indicated by misplaced screws with consistent clinical symptomatology were compared between groups. Pedicle screw placement was graded according to 2-mm increments in medial pedicle wall breach and measurement of screw axis placement. Results: Seven of the 2,345 pedicle screws placed percutaneously with the use of the dual-planar fluoroscopic technique required revision because of a symptomatic misplaced screw, for a screw revision rate of 0.3%. There were no statistically significant demographic differences between patients who had screws revised and those who did not. All screws registered greater than 10 mA on electromyographic stimulation. In the 41 prospectively obtained CT examinations, one out of 141 screws (0.7%) was revised due to pedicle wall breach; whereas among the 104 patients with 352 screws, three screws were revised (0.9%). Conclusions: DPF is an extremely accurate, safe, and reproducible technique for placement of percutaneous pedicle screws and is a readily available and cost-effective alternative to CT-guided pedicle screw placement techniques. Postoperative CT evaluation is not necessary with PLPSP unless the patient is symptomatic. Acceptable electromyographic thresholds may need to be reevaluated.
引用
收藏
页码:238 / 245
页数:8
相关论文
共 50 条
  • [1] Accuracy of Percutaneous Pedicle Screw Placement after Single-Position versus Dual-Position Insertion for Lateral Interbody Fusion and Pedicle Screw Fixation Using Fluoroscopy
    Hiyama, Akihiko
    Katoh, Hiroyuki
    Sakai, Daisuke
    Sato, Masato
    Tanaka, Masahiro
    Watanabe, Masahiko
    [J]. ASIAN SPINE JOURNAL, 2022, 16 (01) : 20 - 27
  • [2] Accuracy of Pedicle Screw Placement Using Intraoperative CT-Guided Navigation and Conventional Fluoroscopy for Lumbar Spondylosis
    Alqurashi, Ashwaq
    Alomar, Soha A.
    Bakhaidar, Mohamad
    Alfiky, Mohammed
    Baeesa, Saleh S.
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (08)
  • [3] Accuracy of Percutaneous Lumbosacral Pedicle Screw Placement Using the Oblique Fluoroscopic View Based on Computed Tomography Evaluations
    Yoshida, Go
    Sato, Koji
    Kanemura, Tokumi
    Iwase, Toshiki
    Togawa, Daisuke
    Matsuyama, Yukihiro
    [J]. ASIAN SPINE JOURNAL, 2016, 10 (04) : 630 - 638
  • [4] The accuracy of pedicle screw placement using intraoperative image guidance systems
    Mason, Alexander
    Paulsen, Renee
    Babuska, Jason M.
    Rajpal, Sharad
    Burneikiene, Sigita
    Nelson, E. Lee
    Villavicencio, Alan T.
    [J]. JOURNAL OF NEUROSURGERY-SPINE, 2014, 20 (02) : 196 - 203
  • [5] Comparison of the Accuracy and Safety of TiRobot-Assisted and Fluoroscopy-Assisted Percutaneous Pedicle Screw Placement for the Treatment of Thoracolumbar Fractures
    Lin, Shu
    Wang, Fei
    Hu, Jiang
    Tang, Liu-yi
    [J]. ORTHOPAEDIC SURGERY, 2022, 14 (11) : 2955 - 2963
  • [6] Percutaneous Pedicle Screw Placement Aided by a New Drill Guide Template Combined with Fluoroscopy: An Accuracy Study
    Wu, Chao
    Deng, Jiayan
    Li, Tao
    Tan, Lun
    Yuan, Dechao
    [J]. ORTHOPAEDIC SURGERY, 2020, 12 (02) : 471 - 479
  • [7] Clinical Accuracy of Computer-Assisted Two-Dimensional Fluoroscopy for the Percutaneous Placement of Lumbosacral Pedicle Screws
    Ravi, Bheeshma
    Zahrai, Ali
    Rampersaud, Raja
    [J]. SPINE, 2011, 36 (01) : 84 - 91
  • [8] A new technique useful for lumbosacral percutaneous pedicle screw placement without fluoroscopy or computer-aided navigation systems
    Tani, Yoichi
    Saito, Takanori
    Taniguchi, Shinichiro
    Ishihara, Masayuki
    Paku, Masaaki
    Adachi, Takashi
    Ando, Muneharu
    [J]. JOURNAL OF ORTHOPAEDIC SCIENCE, 2022, 27 (06) : 1190 - 1196
  • [9] Accuracy of pedicle screw placement using intraoperative neurophysiological monitoring and computed tomography
    Mavrogenis, Andreas F.
    Papagelopoulos, Panayiotis J.
    Korres, Demetrios S.
    Papadopoulos, Konstantinos
    Sakas, Damianos E.
    Pneumaticos, Spiros
    [J]. Journal of Long-Term Effects of Medical Implants, 2009, 19 (01) : 41 - 48
  • [10] Safety and Efficacy of Percutaneous Pedicle Screw Placement Using a Power Tool
    Kojima, Atsushi
    Fujii, Atsushi
    Morioka, Shigeta
    Torii, Yoshiaki
    Arai, Kenichiro
    Sasao, Yutaka
    [J]. SPINE SURGERY AND RELATED RESEARCH, 2018, 2 (01):