USE OF THE EQUILIBRIUM CONTACT-ANGLE AS AN INDEX OF CONTACT SURFACE CLEANLINESS

被引:28
|
作者
YANG, JG
MCGUIRE, J
KOLBE, E
机构
[1] OREGON STATE UNIV,DEPT BIORESOURCE ENGN,CORVALLIS,OR 97331
[2] OREGON STATE UNIV,DEPT FOOD SCI & TECHNOL,CORVALLIS,OR 97331
基金
美国国家科学基金会;
关键词
D O I
10.4315/0362-028X-54.11.879
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Advancing contact angles formed by water and aqueous ethanol solutions were measured on both bare surfaces and film-covered surfaces of acrylic, glass, hydrophilic and hydrophobic silicon, polycarbonate, polyester, and #304 stainless steel. Each bare surface was initially characterized with respect to its hydrophilic/hydrophobic balance. Both homogeneous protein films and heterogenous milk films were prepared on each surface; the adsorbed mass comprising each film was measured with ellipsometry. Contact angle methods proved useful in detecting the presence of a protein film on sufficiently hydrophilic or hydrophobic surfaces, i.e., materials for which W(a)P(water) (the polar component of the energy required to separate water from its surface) is greater than 55 mJ/m2 or less than 37 mJ/m2. Contact angle methods were found to be useful for detecting the presence of a milk film on solid surfaces as well. However, the detection limits were dependent not only on W(a)P(water) but also on the ethanol concentration of the diagnostic liquid used.
引用
收藏
页码:879 / 884
页数:6
相关论文
共 50 条