LIGHT-REFLECTIVE CEREBRAL OXIMETRY AND JUGULAR BULB VENOUS OXYGEN-SATURATION DURING CAROTID ENDARTERECTOMY

被引:74
|
作者
WILLIAMS, IM [1 ]
PICTON, A [1 ]
FARRELL, A [1 ]
MEAD, GE [1 ]
MORTIMER, AJ [1 ]
MCCOLLUM, CN [1 ]
机构
[1] UNIV S MANCHESTER HOSP,DEPT ANAESTHET,MANCHESTER M20 8LR,LANCS,ENGLAND
关键词
D O I
10.1002/bjs.1800810911
中图分类号
R61 [外科手术学];
学科分类号
摘要
A novel instrument using reflected near-infra-red light spectroscopy to measure cerebral oxygen saturation noninvasively was evaluated during carotid endarterectomy; cerebral perfusion was compared with jugular bulb venous oxygen saturation and transcranial Doppler ultrasonographic measurements. Initially, oximetry sensors with light source-detector separation distances of 10 and 27 mm were positioned over the frontal area, while a cannula positioned in the jugular bulb permitted sampling for jugular bulb venous oxygen saturation. To increase cerebral oxygen saturation sensitivity, modified sensors with light source-detector separation distances of 30 and 40 mm were relocated over the middle cerebral artery territory. The changes in cerebral and jugular bulb venous oxygen saturation, and in peak blood flow velocity before and 30 s after carotid clamping and declamping were recorded. The modified cerebral perfusion system achieved improved correlations between cerebral and jugular bulb venous oxygen saturation changes during carotid clamping and declamping (r=0.92, P<0.001). The correlation between change in cerebral oxygen saturation and the percentage change in peak flow velocity on both cross-clamping and declamping was equally strong (r=0.90, P<0.001). Near-infra-red cerebral spectroscopy reliably detects changes in cerebral oxygen saturation during carotid endarterectomy and may have wide applications in monitoring brain perfusion during neurosurgery and cardiopulmonary bypass surgery, and in closed head injury.
引用
收藏
页码:1291 / 1295
页数:5
相关论文
共 50 条
  • [1] LIGHT-REFLECTIVE CEREBRAL OXIMETRY AND JUGULAR BULB OXYGEN-SATURATION DURING CAROTID ENDARTERECTOMY
    WILLIAMS, I
    VOHRA, R
    PICTON, A
    HARDY, S
    MCCOLLUM, CN
    [J]. BRITISH JOURNAL OF SURGERY, 1994, 81 (05) : 759 - 760
  • [2] Antecubital approach for monitoring jugular bulb venous oxygen saturation during carotid endarterectomy
    Satoki Inoue
    Masahiko Kawaguchi
    Hitoshi Furuya
    Toshisuke Sakaki
    [J]. Canadian Journal of Anaesthesia, 2005, 52 : 656 - 657
  • [3] Antecubital approach for monitoring jugular bulb venous oxygen saturation during carotid endarterectomy
    Inoue, S
    Kawaguchi, M
    Furuya, H
    Sakaki, T
    [J]. CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2005, 52 (06): : 656 - 657
  • [4] MONITORING OF THE CEREBRAL OXYGENATION WITH NEAR-INFRARED SPECTROSCOPY IN COMPARISON TO JUGULAR BULB OXYGEN-SATURATION DURING CAROTID ENDARTERECTOMY
    SCHINDLER, E
    ZICKMANN, B
    MULLER, M
    BOLDT, J
    KROLL, J
    HEMPELMANN, G
    [J]. VASA-JOURNAL OF VASCULAR DISEASES, 1995, 24 (02): : 168 - 175
  • [5] JUGULAR VENOUS OXIMETRY DURING CAROTID ENDARTERECTOMY
    DAVIDSON, AJ
    MENDELOW, AD
    CHAMBERS, IR
    FULTON, B
    BULLOCK, RE
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1995, 74 : 68 - 68
  • [6] THE INFLUENCE OF CEREBRAL METABOLIC-RATE ON THE CORRELATION BETWEEN JUGULAR VENOUS OXYGEN-SATURATION AND CEREBRAL BLOOD-FLOW DURING CAROTID ENDARTERECTOMY
    ELLIS, R
    MUIZELAAR, JP
    FRANKS, P
    JESUDIAN, MCS
    KEENAN, RL
    [J]. ANESTHESIOLOGY, 1986, 65 (3A) : A326 - A326
  • [7] JUGULAR VENOUS OXYGEN-SATURATION MONITORING
    CRUZ, J
    [J]. JOURNAL OF NEUROSURGERY, 1992, 77 (01) : 162 - 163
  • [8] BILATERAL NEAR-INFRARED SPECTROSCOPY DURING CAROTID ENDARTERECTOMY - RELATIONSHIP TO TRANSCRANIAL DOPPLER ULTRASONOGRAPHY AND JUGULAR VENOUS OXYGEN-SATURATION
    WILLIAMS, IM
    PICTON, A
    MEAD, GE
    MORTIMER, A
    MCCOLLUM, CN
    [J]. BRITISH JOURNAL OF SURGERY, 1994, 81 (12) : 1824 - 1825
  • [9] INTRACRANIAL HEMODYNAMICS AND JUGULAR BULB OXYGEN-SATURATION DURING CARDIOPULMONARY BYPASS
    VONKNOBELSDORFF, G
    HANEL, F
    WERNER, C
    POKAR, H
    ESCH, JSA
    [J]. ANESTHESIOLOGY, 1994, 81 (3A) : A202 - A202
  • [10] THE SPEED OF BLOOD WITHDRAWAL AFFECTS THE ACCURACY OF JUGULAR VENOUS BULB OXYGEN-SATURATION MEASUREMENTS
    MATTA, BF