LUNG PARENCHYMA - MAGNETIC-SUSCEPTIBILITY IN MR IMAGING

被引:133
|
作者
BERGIN, CJ [1 ]
GLOVER, GH [1 ]
PAULY, JM [1 ]
机构
[1] STANFORD UNIV,DEPT ELECT ENGN,STANFORD,CA 94305
关键词
LUNG; MR STUDIES; MAGNETIC RESONANCE (MR); PULSE SEQUENCES;
D O I
10.1148/radiology.180.3.1871305
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic susceptibility effects in magnetic resonance (MR) imaging of normal lung parenchyma occur because of magnetic-field inhomogeneities induced by the microscopic heterogeneity of the lung. The effects on MR imaging of the lung are loss of signal from intravoxel phase dispersion (measured with T2') and a shift in the macroscopic resonant frequency from that of water toward that of air (DELTA-upsilon). These effects of MR imaging at 1.5 T were quantitated by measuring T2' decay and DELTA-upsilon at different locations in the lungs of two adult volunteers and one excised inflated human lung. The average T2' was 7 msec in the excised inflated specimen and 6.3 msec in normal in vivo lungs. There was a gravitational increase in T2' from nondependent to dependent lung. T2' increased to 35 msec in atelectatic lung tissue and to more than 140 msec in tumor. The macroscopic resonant lung frequency increased to 3.6 ppm more than that of mediastinal muscle. These values are important for developing MR pulse sequences appropriate for imaging lung parenchyma.
引用
收藏
页码:845 / 848
页数:4
相关论文
共 50 条
  • [1] MR IMAGING OF LUNG PARENCHYMA - A SOLUTION TO SUSCEPTIBILITY
    BERGIN, CJ
    NOLL, DC
    PAULY, JM
    GLOVER, GH
    MACOVSKI, A
    RADIOLOGY, 1992, 183 (03) : 673 - 676
  • [2] MAGNETIC-SUSCEPTIBILITY ARTIFACTS IN GRADIENT-RECALLED ECHO MR IMAGING
    CZERVIONKE, LF
    DANIELS, DL
    WEHRLI, FW
    MARK, LP
    HENDRIX, LE
    STRANDT, JA
    WILLIAMS, AL
    HAUGHTON, VM
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1988, 9 (06) : 1149 - 1155
  • [3] MR spectroscopic imaging of lung parenchyma
    Gold, GE
    Pauly, JM
    Sze, RW
    Leung, AN
    Macovski, A
    Stark, P
    RADIOLOGY, 1996, 201 : 406 - 406
  • [4] MAGNETIC-SUSCEPTIBILITY ARTIFACT IN SPIN-ECHO MR IMAGING OF THE PITUITARY-GLAND
    SAKURAI, K
    FUJITA, N
    HARADA, K
    KIM, SW
    NAKANISHI, K
    KOZUKA, T
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1992, 13 (05) : 1301 - 1308
  • [5] DEMARCATION OF MYOCARDIAL ISCHEMIA - MAGNETIC-SUSCEPTIBILITY EFFECT OF CONTRAST-MEDIUM IN MR IMAGING
    SAEED, M
    WENDLAND, MF
    TOMEI, E
    ROCKLAGE, SM
    QUAY, SC
    MOSELEY, ME
    WOLFE, C
    HIGGINS, CB
    RADIOLOGY, 1989, 173 (03) : 763 - 767
  • [6] MR CONTRAST DUE TO INTRAVASCULAR MAGNETIC-SUSCEPTIBILITY PERTURBATIONS
    BOXERMAN, JL
    HAMBERG, LM
    ROSEN, BR
    WEISSKOFF, RM
    MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (04) : 555 - 566
  • [7] MEASUREMENT OF MAGNETIC-SUSCEPTIBILITY AND MR CONTRAST AGENT CONCENTRATION
    WEIS, J
    NILSSON, S
    ERICSSON, A
    WIKSTROM, M
    SPERBER, GO
    HEMMINGSSON, A
    MAGNETIC RESONANCE IMAGING, 1994, 12 (06) : 859 - 864
  • [8] LUNG PARENCHYMA - PROJECTION RECONSTRUCTION MR-IMAGING
    BERGIN, CJ
    PAULY, JM
    MACOVSKI, A
    RADIOLOGY, 1991, 179 (03) : 777 - 781
  • [9] MAGNETIC-SUSCEPTIBILITY SHIFT SELECTED IMAGING - MESSI
    XU, Y
    BALSCHI, JA
    SPRINGER, CS
    MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (01) : 80 - 90
  • [10] NMR IMAGING AND MAGNETIC-SUSCEPTIBILITY OF DENTAL MATERIALS
    BEUF, O
    LISSAC, M
    BRIGUET, A
    JOURNAL OF DENTAL RESEARCH, 1995, 74 (03) : 924 - 924