LONG-TERM FOLLOW-UP OF PATIENTS WITH SINGLE-LEAD VDD STIMULATION

被引:18
|
作者
FOLINO, AF
BUJA, G
RUZZA, L
NAVA, A
机构
[1] Department of Cardiology, University of Padova, Padova
来源
关键词
SINGLE LEAD PACING; VDD PACING; FOLLOW-UP;
D O I
10.1111/j.1540-8159.1994.tb03762.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to assess the long-term results of a single lead VDD pacing system (Phymos MPS) in 85 patients (48 males, 37 females, mean age 74 +/- 9 years). The system, which incorporates two atrial floating electrodes (Phymos 830-S), was implanted for second- or third-degree Mobitz II AV block. The percentage of AV Synchronized pacing, the presence of fusion beats due to short AV delay, and the occurrence of supraventricular arrhythmias was evaluated by Holter monitoring at 6-month intervals. Over a mean period of follow-up of 44 months (range 2-56), over 90% of AV synchronized pacing events were noted in 74 patients (87%). The presence of persistent fusion beats was detected in 12 patients (14%). In ten patients the pacemaker was reprogrammed to VVI mode for supraventricular arrhythmias (7 patients, 8.2%) or unsatisfactory atrial sensing (3 patients, 3.5%). One pacemaker was removed for pocket infection and two for battery depletion. These observations support the use of VDD single lead pacing to combine a physiological mode of stimulation with simple implantation techniques.
引用
收藏
页码:1854 / 1858
页数:5
相关论文
共 50 条
  • [1] Are there any differences in long-term follow-up of single-lead VDD or DDD pacemakers in atrioventricular block?
    Martinez, JG
    Ibañez, A
    Marin, F
    Climent, V
    Garcia, A
    Oliver, C
    Valencia, J
    Pineda, J
    Arrarte, V
    Sogorb, F
    [J]. EUROPEAN HEART JOURNAL, 2001, 22 : 186 - 186
  • [2] Long-term follow-up of VDD-single-lead pacemaker systems
    Israel, CW
    Floren, E
    Weber, K
    Mumme, A
    [J]. EUROPACE '97 - THE OFFICIAL MEETING OF THE WORKING GROUPS ON CARDIAC PACING AND ARRHYTHMIAS OF THE EUROPEAN SOCIETY OF CARDIOLOGY, 1997, : 867 - 871
  • [3] Single-lead VDD-VDDR system follow-up: long-term supraventricular arrhythmias incidence detected by pacer telemetry
    Cornacchia, D
    Fabbri, M
    Bocconcelli, P
    Sgarbi, E
    Facchin, D
    Proclemer, A
    Giani, P
    Leoni, G
    Corbucci, G
    [J]. PACEMAKER LEADS 1997, 1997, : 205 - 208
  • [4] Single-lead VDD pacing: Long-term experience with four different systems
    Rey, JL
    Tribouilloy, C
    Elghelbazouri, F
    Otmani, A
    [J]. AMERICAN HEART JOURNAL, 1998, 135 (06) : 1036 - 1039
  • [5] Single lead VDD pacing - Analysis of complications and long-term follow-up - Three-year experience
    Grygier, M
    Stanek, K
    Smukowski, T
    Prech, M
    Zerbe, F
    Grajek, S
    Cieslinski, A
    [J]. NEW TRENDS IN ELECTROCARDIOLOGY, 2000, : 113 - 118
  • [6] Single-lead VDD pacing: a literature review on short-term and long-term performance
    Mei, Davide Antonio
    Imberti, Jacopo Francesco
    Vitolo, Marco
    Bonini, Niccolo
    Gerra, Luigi
    Romiti, Giulio Francesco
    Proietti, Marco
    Lip, Gregory Y. H.
    Boriani, Giuseppe
    [J]. EXPERT REVIEW OF MEDICAL DEVICES, 2023, 20 (03) : 187 - 197
  • [7] VDD pacing with single pass lead. Experience from the implantation and long term follow-up of 106 patients
    Manolis, AG
    Katsivas, A
    Dragios, D
    Vassilopoulos, C
    Louvros, N
    [J]. EUROPACE '97 - THE OFFICIAL MEETING OF THE WORKING GROUPS ON CARDIAC PACING AND ARRHYTHMIAS OF THE EUROPEAN SOCIETY OF CARDIOLOGY, 1997, : 781 - 784
  • [8] Lead Fractures in Deep Brain Stimulation during Long-Term Follow-Up
    Seijo Fernandez, Fernando
    Alvarez Vega, Marco Antonio
    Antuna Ramos, Aida
    Fernandez Gonzalez, Fernando
    Lozano Aragoneses, Beatriz
    [J]. PARKINSONS DISEASE, 2010, 2010
  • [9] Thalamic stimulation in patients with multiple sclerosis: Long-term follow-up
    Schulder, M
    Karimi, R
    Sernas, TJ
    [J]. NEUROSURGERY, 2003, 53 (02) : 475 - 475
  • [10] One year follow-up of single-lead DDD stimulation using the OLBI principle