Analysis of high-frequency signal-averaged ECG measurements

被引:15
|
作者
Xue, QZ [1 ]
Reddy, BRS [1 ]
Aversano, T [1 ]
机构
[1] JOHNS HOPKINS UNIV HOSP,BALTIMORE,MD 21205
关键词
signal-averaged EGG; myocardial infarction; root-mean-square voltage; high-frequency QRS energy; high-frequency integral of absolute value;
D O I
10.1016/S0022-0736(95)80065-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Analysis of high frequency (150-250 Hz) in the signal-averaged electrocardiogram (SAECG) is one of the emerging methods for detecting vessel patency in acute myocardial infarction following thrombolytic therapy and angioplasty. Root mean-square voltage (RMSV) of the filtered QRS has been used in earlier studies to detect reperfusion; however, previous analysis indicated that RMSV is sensitive to residual noise in the SAECG and errors in QRS delineation (onset/offset). A new measurement is proposed, high-frequency energy (HFQE), and the robustness of the RMSV and HFQE was evaluated for simulated errors in QRS delineation. In this study two measures (RMSV and HFQE) were tested on 24 control subjects and 21 patients undergoing thrombolytic therapy. Results indicate that unfiltered QRS duration is more stable than filtered QRS duration for the control subjects and patients and that HFQE had less fluctuation than RMSV in thrombolytic therapy patients. In the control group, HFQE was sensitive to the amplitude variation of the filtered SAECG. Therefore, another new measurement is proposed high-frequency integral of absolute value (HFAV), for reducing the sensitivity to amplitude changes in the filtered SAECG. This new feature was tested on control subjects and was found to be more stable than HFQE. In the thrombolytic therapy group, HFAV provided similar information as HFQE. These three measurements-RMSV, HFQE, and HFAV-provide a comprehensive analysis of the high-frequency SAECG for detecting vessel patency and reocclusion. Relative merits of these measures need to be evaluated on a larger database of patients undergoing thrombolysis and angioplasty for acute myocardial infarction.
引用
收藏
页码:239 / 245
页数:7
相关论文
共 50 条
  • [1] FAST AND RELIABLE QRS ALIGNMENT TECHNIQUE FOR HIGH-FREQUENCY ANALYSIS OF SIGNAL-AVERAGED ECG
    ESCALONA, OJ
    MITCHELL, RH
    BALDERSON, DE
    HARRON, DWG
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1993, 31 : S137 - S146
  • [2] HIGH-FREQUENCY ANALYSIS OF THE SIGNAL-AVERAGED ECG - CORRELATION WITH LEFT-VENTRICULAR MASS IN RABBITS
    OKIN, PM
    DONNELLY, TM
    PARKER, TS
    WALLERSON, DC
    MAGID, NM
    KLIGFIELD, P
    [J]. JOURNAL OF ELECTROCARDIOLOGY, 1992, 25 (02) : 111 - 118
  • [3] The signal-averaged high-resolution ECG
    Selvester, RHS
    [J]. JOURNAL OF ELECTROCARDIOLOGY, 1995, 28 : 216 - 225
  • [4] ADVANCED TIME-FREQUENCY METHODS FOR SIGNAL-AVERAGED ECG ANALYSIS
    JONES, DL
    TOUVANNAS, JS
    LANDER, P
    ALBERT, DE
    [J]. JOURNAL OF ELECTROCARDIOLOGY, 1993, 25 : 188 - 194
  • [5] THE SIGNAL-AVERAGED ECG - TIME - DOMAIN ANALYSIS
    BREITHARDT, G
    WICHTER, T
    FETSCH, T
    SEIFERT, T
    BORGGREFE, M
    SHENASA, M
    REINHARDT, L
    [J]. EUROPEAN HEART JOURNAL, 1993, 14 : 27 - 32
  • [6] Frequency analysis of the signal-averaged ECG of postinfarction patients for prediction of cardiac death
    Sierra, G
    Morel, P
    Le Guyader, P
    Tréllez, F
    Nadeau, R
    Savard, P
    [J]. PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 76 - 77
  • [7] Intra-QRS high-frequency ECG changes with ischermia - Is it possible to evaluate these changes using the signal-averaged holter ECG in dogs?
    Yakubo, SJ
    Ozawa, Y
    Komaki, K
    [J]. JOURNAL OF ELECTROCARDIOLOGY, 1995, 28 : 234 - 238
  • [8] The P wave signal-averaged ECG
    Ehlert, FA
    Steinberg, JS
    [J]. JOURNAL OF ELECTROCARDIOLOGY, 1995, 28 : 33 - 38
  • [9] Normal values for the childhood signal-averaged ECG
    Davis, AM
    McCrindle, BW
    Hamilton, RM
    MooreColeman, P
    Gow, RM
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (05): : 793 - 801
  • [10] An improved method of signal-averaged ECG processing
    Kravchenko, VF
    Popov, AY
    Fernandes, HCC
    [J]. 6TH WORLD MULTICONFERENCE ON SYSTEMICS, CYBERNETICS AND INFORMATICS, VOL XVI, PROCEEDINGS: COMPUTER SCIENCE III, 2002, : 47 - 49