A TEMPORARY DISSECTING SETON FOR TRABECULECTOMY - DELAYED RE-CREATION OF THE GLAUCOMA FILTERING SCLEROSTOMY AND BLEB

被引:0
|
作者
GROSS, PG
机构
[1] BRYN MAWR HOSP,BRYN MAWR,PA
[2] UNIV PENN,SCHEIE EYE INST,DEPT OPHTHALMOL,PHILADELPHIA,PA 19104
[3] WILLS EYE HOSP & RES INST,PHILADELPHIA,PA 19107
来源
OPHTHALMIC SURGERY AND LASERS | 1993年 / 24卷 / 11期
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Presented is a new surgical technique to re-create the entire filtering pathway 2 weeks following trabeculectomy. The dissecting seton is a suture loop of 9-0 nylon, silk, or polypropylene placed in the potential outflow space of the sclerostomy and bleb area during trabeculectomy. The seton is pulled out at the slit lamp, under topical anesthesia, 1 to 3 weeks after the initial surgery in order to re-create the filtration pathway. By pulling on the seton, a cheesewiring dissection severs newly formed fibrovascular tissue that may have occluded or constricted the previously created aqueous outflow tract at any point(s). Because of the significant time delay, the reopened filtration pathway is, for the first time, filled with flowing aqueous of nearly normal composition under a well-healed conjunctiva as a result of a nearly normally functioning ciliary body in a nearly quiet eye. Delayed postoperative re-creation of the bleb with the dissecting seton may be combined with other management techniques such as 5-fluorouracil subconjunctival injections, suture cuttings, bleb massage, etc. This technique has been used in nine cases with follow up ranging from a few weeks to 1 year. All were trabeculectomies with phacoemulsification and intraocular lens implantation. Both initial placement and subsequent handling of the dissecting seton appear to be safe, quick, easy, and inexpensive. Complications or failures have all been minor and easily managed.
引用
收藏
页码:775 / 779
页数:5
相关论文
共 4 条
  • [1] TEMPORARY DISSECTING SETON FOR TRABECULECTOMY - RESPONSE
    GROSS, PG
    [J]. OPHTHALMIC SURGERY AND LASERS, 1994, 25 (06): : 412 - 413
  • [2] Recurrent Endophthalmitis after Trabeculectomy for Glaucoma: Importance of Timely Filtering Bleb Coverage for the Conjunctiva
    Schoenfeld, Carl-Ludwig
    [J]. CASE REPORTS IN OPHTHALMOLOGY, 2012, 3 (03): : 360 - 363
  • [3] Partial excision with a conjunctival advancement flap after a relaxing incision for a dissecting glaucoma filtering bleb
    Mandal, AK
    Vemuganti, GK
    Ladda, N
    Veenashree, MP
    [J]. OPHTHALMIC SURGERY AND LASERS, 2002, 33 (06): : 497 - 500
  • [4] Does type of postoperative anti-glaucoma drug affect morphological changes of filtering bleb after trabeculectomy? - Utilizing the data from the Collaborative Bleb-Related Infection Incidence and Treatment Study
    Yamamoto, Yuji
    Mori, Kazuhiko
    Yokota, Isao
    Ikeda, Yoko
    Ueno, Mario
    Imai, Kojiro
    Yoshikawa, Haruna
    Teramukai, Satoshi
    Kinoshita, Shigeru
    Sotozono, Chie
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)