Test Method to Measure the Relative Capacity of Wall Panels to Evacuate Moisture from Their Stud Cavity

被引:7
|
作者
Fazio, Paul [1 ]
Mao, Qian [1 ]
Ge, Hua [1 ]
Alturkistani, Arslan [1 ]
Rao, Jiwu [1 ]
机构
[1] Concordia Univ, Dept Bldg Civil & Environm Engn, Montreal, PQ, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Building design; Damage; Dewatering; Envelope; Moisture;
D O I
10.1061/(ASCE)1076-0431(2007)13:4(194)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Rainwater penetration is the source of moisture that causes the greatest damage to building envelope assemblies. The building envelope should be designed to reduce the amount of rainwater penetration by deflection and drainage. Since it is not realistic to assume a perfect wall without any leakage, the envelope should have the drying capacity to tolerate defects that may arise from the design, construction, and aging of the exterior wall system. Systems with a greater capacity to evacuate moisture from the stud cavity are less likely to undergo moisture damage. A new testing method is developed and deployed to evaluate the relative drying capacity of six wood-framed wall panels of different configurations built into a test hut and tested within a large scale environmental chamber. The wall panels used plywood, oriented strand board (OSB), or fiberboard as sheathing, but did not include cladding. A uniform moisture source was introduced in a water tray set on a load cell at the bottom of each stud cavity. The protocol is based on the hypothesis that the potential for moving a water molecule from the bottom plate to the exterior of the stud cavity is independent of the previous journey of that molecule, i.e., whether it has traveled from the interior of the bottom plate to the surface of the plate or whether it comes from free water in a tray at the level of the bottom plate. For a given set of boundary conditions, this potential is a function of the characteristics of the wall panel, and is identified as the drying capacity of the panel or its drying by evaporation index (DEI). The value of DEI corresponds to the evaporation rate. The moisture response of wall materials enclosing the stud cavity and the evaporation rate of the moisture source were monitored. The results show that this index can be used as an indicator of the relative drying capacity of different wall systems.
引用
收藏
页码:194 / 204
页数:11
相关论文
共 17 条
  • [1] A new test method to determine the relative drying capacity of building envelope panels of various configurations
    Alturkistani, Arslan
    Fazio, Paul
    Rao, Jiwu
    Mao, Qian
    [J]. BUILDING AND ENVIRONMENT, 2008, 43 (12) : 2203 - 2215
  • [2] A Method to Measure the Relative Brine Release Capacity of Geologic Material
    Stormont, John C.
    Hines, Joleen S.
    O'Dowd, Daniel N.
    Kelsey, James A.
    Pease, R. Eric
    [J]. GEOTECHNICAL TESTING JOURNAL, 2011, 34 (05): : 406 - 412
  • [3] Evaluation of exterior wall cavity fires using an intermediate scale test method
    Weerakkody, Neythra
    White, Nathan
    Moinuddin, Khalid
    [J]. FIRE AND MATERIALS, 2024,
  • [4] Round robin test on a cavity resonance method to measure complex permittivity of dielectric plates at microwave frequency
    Kobayashi, Yoshio
    Nakayama, Akira
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2006, 13 (04) : 751 - 759
  • [5] Heat and moisture diffusion in spruce and wood panels computed from 3-D morphologies using the Lattice Boltzmann method
    Louerat, M.
    Ayouz, M.
    Perre, P.
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2018, 130 : 471 - 483
  • [6] Static pile capacity from the rapid test via the unloading-point method
    Luker, I
    [J]. JOURNAL OF THE SOUTH AFRICAN INSTITUTION OF CIVIL ENGINEERING, 2021, 63 (02) : 19 - 26
  • [7] Elimination of porcine reproductive and respiratory syndrome virus from a seedstock breeding farm and a supplying boar stud by a modified test and removal method
    Yang, J. S.
    Moon, H. J.
    Lee, C. S.
    Park, S. J.
    Song, D. S.
    Kang, B. K.
    Choi, J. U.
    Park, B. K.
    [J]. VETERINARY RECORD, 2008, 162 (11) : 333 - 337
  • [8] Round robin test on a cavity resonance method to measure complex permittivity of dielectric plates at microwave frequency (vol 13, pg 751, 2006)
    Kobayashi, Yoshio
    Nakayama, Akira
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2006, 13 (06) : 1378 - 1378
  • [9] Development of a test method using a VOC analyzer to measure VOC emission from adhesives for building materials
    Kim, Sumin
    Kim, Jin-A
    An, Jae-Yoon
    Kim, Hyun-Joong
    Moon, Suck-Joong
    [J]. JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 2006, 20 (15) : 1783 - 1799
  • [10] An analytic method for two-dimensional wall motion and product isentrope from the detonation cylinder test
    Jackson, Scott I.
    [J]. PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2015, 35 : 1997 - 2004