IMPROVED IMAGING OF BONE WITH SCAN EQUALIZATION RADIOGRAPHY

被引:4
|
作者
WANDTKE, JC
PLEWES, DB
机构
[1] Dept. of Diagnostic Radiology, University of Rochester, Medical Center, Rochester, NY 14642
关键词
D O I
10.2214/ajr.157.2.1853822
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Use of scan equalization radiography (SER) for imaging bone in the head, face, neck, and shoulder was evaluated in a clinical comparison study with conventional radiographs of randomly selected patients. Two hundred nine pairs of normal and abnormal SER images and conventional radiographs were compared by four radiologists in a side-by-side viewing situation. The radiologists compared the visibility of specific anatomic features and rated the SER images as better than, equal to, or worse than the conventional radiographs. In the evaluation of the images of the cervical spine, the radiologists much preferred the SER images 63% of the time because of slight improvement in bone detail and marked improvement in detail of the soft tissues. In the evaluation of the images of the shoulder, the radiologists preferred the SER image 58% of the time and preferred the conventional radiograph only 5% of the time (p < .05). In the evaluation of the images of the skull, face, and mandible, the radiologists preferred the SER images 62% of the time and the conventional images 4% of the time (p < .05). The superior image quality with the SER technique was recognized by all radiologists in the study and was the overwhelmingly preferred way of imaging the shoulder, neck, head, and face.
引用
收藏
页码:359 / 364
页数:6
相关论文
共 50 条
  • [1] A SCANNING EQUALIZATION SYSTEM FOR IMPROVED CHEST RADIOGRAPHY
    PLEWES, DB
    WANDTKE, JC
    RADIOLOGY, 1982, 142 (03) : 765 - 768
  • [2] IMPROVED PULMONARY NODULE DETECTION WITH SCANNING EQUALIZATION RADIOGRAPHY
    WANDTKE, JC
    PLEWES, DB
    MCFAUL, JA
    RADIOLOGY, 1988, 169 (01) : 23 - 27
  • [3] Rejection and redistribution of scattered radiation in scan equalization digital radiography (SEDR)
    Liu, X
    Shaw, C
    Altunbas, M
    Wang, T
    MEDICAL PHYSICS, 2004, 31 (06) : 1810 - 1810
  • [4] Improved detection of focal pneumonia by chest radiography with bone suppression imaging
    Feng Li
    Roger Engelmann
    Lorenzo Pesce
    Samuel G. Armato
    Heber MacMahon
    European Radiology, 2012, 22 : 2729 - 2735
  • [5] IMPROVED CHEST DISEASE DETECTION WITH SCANNING EQUALIZATION RADIOGRAPHY
    WANDTKE, JC
    PLEWES, DB
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1985, 145 (05) : 979 - 983
  • [6] Improved detection of focal pneumonia by chest radiography with bone suppression imaging
    Li, Feng
    Engelmann, Roger
    Pesce, Lorenzo
    Armato, Samuel G., III
    MacMahon, Heber
    EUROPEAN RADIOLOGY, 2012, 22 (12) : 2729 - 2735
  • [7] Comparison of scatter rejection and low-contrast performance of scan equalization digital radiography (SEDR), slot-scan digital radiography, and full-field digital radiography systems for chest phantom imaging
    Liu, Xinming
    Shaw, Chris C.
    Lai, Chao-Jen
    Wang, Tianpeng
    MEDICAL PHYSICS, 2011, 38 (01) : 23 - 33
  • [8] Scan equalization digital radiography (SEDR) - Implementation with a flat-panel detector
    Liu, XM
    Shaw, CC
    Altunbas, MC
    Wang, TP
    Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 1112 - 1120
  • [9] Late diagnosed polyostotic fibrous dysplasia. Bone scan, radiography and magnetic resonance imaging findings
    Esmaili, Javad
    Chavoshi, Maryam
    Noorani, Mohammad Hadi
    Eftekhari, Mohammad
    Assadi, Majid
    HELLENIC JOURNAL OF NUCLEAR MEDICINE, 2010, 13 (01): : 65 - 66
  • [10] Noise simulation for studying the effects of scanning geometries and equalization schemes in scan exposure-equalization digital radiography (SEDR)
    Balter, P
    Kappadath, S
    Liu, X
    Shaw, C
    MEDICAL PHYSICS, 2002, 29 (06) : 1343 - 1343