DESIGN AND PERFORMANCE OF THE HEAD PENN-PET SCANNER

被引:37
|
作者
FREIFELDER, R [1 ]
KARP, JS [1 ]
GEAGAN, M [1 ]
MUEHLLEHNER, G [1 ]
机构
[1] UGM MED SYST INC,PHILADELPHIA,PA 19104
基金
美国国家卫生研究院;
关键词
D O I
10.1109/23.322928
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new PET scanner for brain imaging (and animals) has been designed with very high sensitivity and spatial resolution. The design is an evolution of the PENN-PET scanner, which uses large position-sensitive NaI(Tl) detectors, with Anger-type positioning logic, and which allows 3-D volume imaging, without septa. The new design is built with a single annular crystal coupled to 180 photomultiplier tubes, and uses local triggering electronics to subdivide the detector into small zones and to determine coincident events within the detector. The axial acceptance angle of +/- 27 deg, with a field-of-view of 25.6 cm, is larger than any currently operating PET scanner. Performance measurements are presented.
引用
收藏
页码:1436 / 1440
页数:5
相关论文
共 50 条
  • [1] THE COUNTRATE PERFORMANCE OF THE VOLUME IMAGING PENN-PET SCANNER
    SMITH, RJ
    KARP, JS
    MUEHLLEHNER, G
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (04) : 610 - 618
  • [2] Data processing and image reconstruction methods for the HEAD PENN-PET scanner
    Karp, JS
    Becher, AJ
    Matej, S
    Kinahan, PE
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 1144 - 1151
  • [3] Three-dimensional imaging characteristics of the HEAD PENN-PET scanner
    Karp, JS
    Freifelder, R
    Geagan, MJ
    Muehllehner, G
    Kinahan, PE
    Lewitt, RM
    Shao, LX
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (04) : 636 - 643
  • [4] HEAD PENN-PET scanner: A novel instrument for the investigation of neuropsychiatric disorders.
    Snyder, LC
    Alavi, A
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 280P - 281P
  • [5] STANDARDS FOR PERFORMANCE-MEASUREMENTS OF PET SCANNERS - EVALUATION WITH THE UGM PENN-PET 240H SCANNER
    KARP, JS
    MUEHLLEHNER, G
    [J]. MEDICAL PROGRESS THROUGH TECHNOLOGY, 1991, 17 (3-4) : 173 - 187
  • [6] Initial clinical experience with ultra high resolution, large field of view, volume imaging head PENN-PET scanner.
    Alavi, A
    Karp, JS
    Freifelder, R
    Smith, RJ
    Riggin, S
    Kilroy, K
    Mozley, PD
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 1234 - 1234
  • [7] A POSITRON CAMERA USING POSITION-SENSITIVE DETECTORS - PENN-PET
    MUEHLLEHNER, G
    KARP, JS
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1986, 27 (01) : 90 - 98
  • [8] CONTINUOUS-SLICE PENN-PET - A POSITRON TOMOGRAPH WITH VOLUME IMAGING CAPABILITY
    KARP, JS
    MUEHLLEHNER, G
    MANKOFF, DA
    ORDONEZ, CE
    OLLINGER, JM
    DAUBEWITHERSPOON, ME
    HAIGH, AT
    BEERBOHM, DJ
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1990, 31 (05) : 617 - 627
  • [9] Performance characteristics of a dual head SPECT scanner with PET capability
    Nellemann, P
    Hines, H
    Braymer, W
    Muehllehner, G
    Geagan, M
    [J]. 1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1751 - 1755
  • [10] Design and performance of a preclinical proton CT head scanner
    Schulte, R.
    Bashkirov, V.
    Giacometti, V.
    Hurley, R. F.
    Johnson, R. P.
    Plautz, T.
    Piersimoni, P.
    Sadrozinski, H. F. W.
    Schubert, K. E.
    Schultze, B.
    Vence, N.
    Zatserklyaniy, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S199 - S199