A JUSTIFICATION FOR HIGH-RESOLUTION HEMATOCRIT MEASUREMENT

被引:0
|
作者
KELLY, ME [1 ]
LUETKEMEIER, MJ [1 ]
PANTALOS, GM [1 ]
机构
[1] UNIV UTAH,DEPT EXERCISE & SPORT SCI,DEPT BIOENGN,SALT LAKE CITY,UT 84112
来源
关键词
MICROHEMATOCRIT; COULTER COUNTER; PLASMA VOLUME; DIGITAL CALIPERS; DENSITY; RELIABILITY; VALIDITY; STANDARD ERROR OF MEASUREMENT (SE(M)); CONFIDENCE INTERVAL;
D O I
暂无
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The purpose of this study was to determine the feasibility of using a 6'' digital caliper and a 20x viewing microscope to measure hematocrit (HCT) from microhematocrit tubes. The reliability and validity of the digital caliper technique (DC) was simultaneously compared with that of the conventional ''turntable'' style microhematocrit method (MC) and the Coulter Counter(TM) hematocrit (CC) for a comprehensive comparison of the three methods. The reliability of the three methods was assessed by computing the standard error of the measurement (SE(m)) on triplicate readings of human blood samples. The SE(m) for MC, CC, and DC methods were 0.3555, 0.3004, and 0.1491, respectively. Validity was assessed by comparing the average of the triplicate HCT readings for each method with HCT determined by densitometry. Average HCT values (+/-SE) for the MC, CC, DC, and densitometry methods were 42.3 +/- 3.2, 42.4 +/- 3.4, 43.1 +/- 3.4, 43.7 +/- 3.3, respectively. Only the DC HCT values were not different from the densitometry HCT (P > 0.05). The MC and CC values were significantly lower (P < 0.01). It is concluded that accurate, highly precise measurements of HCT are obtainable using the digital caliper. The significance for this is the increased ability to perform extremely accurate measurement of changes in plasma volume. With this information, research labs can reliably measure smaller changes in plasma than was previously possible with commercial procedures.
引用
收藏
页码:547 / 550
页数:4
相关论文
共 50 条
  • [1] High-resolution Measurement of Seawater Carbonate
    McGraw, Christina
    [J]. JUNCTURES-THE JOURNAL FOR THEMATIC DIALOGUE, 2018, (19): : 47 - 48
  • [2] HIGH-RESOLUTION AND THE ACCURATE MEASUREMENT OF INTENSITIES
    JOHNS, JWC
    [J]. MIKROCHIMICA ACTA, 1987, 3 (1-6): : 171 - 188
  • [3] HIGH-RESOLUTION MEASUREMENT OF MULTILAYER STRUCTURES
    MERKLEIN, TM
    [J]. APPLIED OPTICS, 1990, 29 (04): : 505 - 511
  • [4] HIGH-RESOLUTION ULTRASONIC BLOODFLOW MEASUREMENT
    SIEGEL, M
    OLINGER, M
    HO, B
    [J]. IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1977, 24 (02): : 129 - 129
  • [5] HIGH-RESOLUTION ULTRASOUND TRANSVERSE FLOW MEASUREMENT
    NIKOONAHAD, M
    LI, F
    [J]. ELECTRONICS LETTERS, 1988, 24 (04) : 205 - 207
  • [6] Femtosecond high-resolution spectral phase measurement
    Chu, KC
    Grant, RS
    Heritage, JP
    Sullivan, A
    White, WE
    [J]. GENERATION, AMPLIFICATION, AND MEASUREMENT OF ULTRASHORT LASER PULSES III, 1996, 2701 : 126 - 132
  • [7] High-resolution photomask phase measurement tool
    Merriam, AJ
    Jacob, JJ
    [J]. 22ND ANNUAL BACUS SYMPOSIUM ON PHOTOMASK TECHNOLOGY, PTS 1 AND 2, 2002, 4889 : 354 - 364
  • [8] HIGH-RESOLUTION MEASUREMENT OF CIRCADIAN PERIODICITIES IN ACETABULARIA
    VONLINDERN, L
    BERGER, S
    MERGENHAGEN, D
    [J]. CHRONOBIOLOGY INTERNATIONAL, 1994, 11 (01) : 1 - 20
  • [10] HIGH-RESOLUTION GEOMETRY MEASUREMENT WITH A COLLABORATIVE ROBOT
    Riedl, M.
    Denzl, R.
    Felberbauer, M.
    Lankmair, T.
    [J]. MM SCIENCE JOURNAL, 2019, 2019 : 3386 - 3392