BIOMECHANICAL ANALYSIS OF THE DYNAMIC HIP SCREW IN THE TREATMENT OF INTERTROCHANTERIC FRACTURES

被引:20
|
作者
WU, CC [1 ]
SHIH, CH [1 ]
机构
[1] CHANG GUNG MEM HOSP, CHANG GUNG MED COLL, DEPT ORTHOPED, TAOYUAN, TAIWAN
关键词
D O I
10.1007/BF00443464
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A prospective study was performed in 148 elderly patients (over 60 years old) whose intertrochanteric fractures were caused by moderate trauma. The patients were treated with dynamic hip screws and followed up for at least 2 years (average 34 months). The lag screw was placed as the biomechanical analysis favored. Follow-up showed that the majority achieved good union and were without mechanical failure. The authors conclude that a lag screw should ideally be placed inferiorly toward the medial margin in the frontal plane and centrally in the sagittal plane. The length of the lag screw should be such as to extend from 1.0 cm beneath the subchondral bone to the lateral femoral cortex. At least four cortical screws (piercing the cortex at eight points) should be inserted on the distal femoral fragment.
引用
收藏
页码:307 / 310
页数:4
相关论文
共 50 条
  • [1] Limited Dynamic Hip Screw for Treatment of Intertrochanteric Fractures: A Biomechanical Study
    Zhang, Chunlei
    Zhang, Bin
    Dong, Qirong
    Ge, Dawei
    [J]. MEDICAL SCIENCE MONITOR, 2018, 24 : 1769 - 1775
  • [2] Biomechanical analysis of location of lag screw of a dynamic hip screw in treatment of unstable intertrochanteric fracture
    Wu, CC
    Shih, CH
    Lee, MY
    Tai, CL
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1996, 41 (04): : 699 - 702
  • [3] Biomechanical analysis of the treatment of intertrochanteric hip fracture with different lengths of dynamic hip screw side plates
    Wang, Cheng-Chi
    Lee, Cheng-Hung
    Chin, Ning-Chien
    Chen, Kun-Hui
    Pan, Chien-Chou
    Su, Kuo-Chih
    [J]. TECHNOLOGY AND HEALTH CARE, 2020, 28 (06) : 593 - 602
  • [4] Treatment of intertrochanteric fractures in elderly patients using dynamic hip screw
    Quang-Tri Le
    Minh-Hoang Nguyen
    [J]. MEDICAL SCIENCE, 2020, 24 (102) : 912 - 921
  • [5] Dynamic hip screw blade fixation for intertrochanteric hip fractures
    Dhamangaonkar, Anoop C.
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY, 2013, 21 (01) : 132 - 133
  • [6] Dynamic hip screw blade fixation for intertrochanteric hip fractures
    Leung, Frankie
    Gudushauri, Paata
    Yuen, Grace
    Lau, Tak-Wing
    Fang, Christian
    Chow, Shew-Ping
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY, 2012, 20 (03): : 302 - 306
  • [7] Helical blade versus sliding hip screw for treatment of unstable intertrochanteric hip fractures: A biomechanical evaluation
    Strauss, Eric
    Frank, Joshua
    Lee, Jason
    Kummer, Frederick J.
    Tejwani, Nirmal
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2006, 37 (10): : 984 - 989
  • [8] THE MANAGEMENT OF INTERTROCHANTERIC FRACTURES OF FEMUR BY DYNAMIC HIP SCREW
    Singh, Arvinder
    [J]. JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2014, 3 (74): : 15575 - 15579
  • [9] Dynamic hip screw in the treatment of intertrochanteric fractures: a comparison of two fixation methods
    Yih-Shiunn Lee
    Hui-Ling Huang
    Ting-Ying Lo
    Chien-Rae Huang
    [J]. International Orthopaedics, 2007, 31 : 683 - 688
  • [10] Dynamic hip screw in the treatment of intertrochanteric fractures: a comparison of two fixation methods
    Lee, Yih-Shiunn
    Huang, Hui-Ling
    Lo, Ting-Ying
    Huang, Chien-Rae
    [J]. INTERNATIONAL ORTHOPAEDICS, 2007, 31 (05) : 683 - 688