An uncertainty metric to evaluate deformation vector fields for dose accumulation in radiotherapy

被引:5
|
作者
Takemura, Akihiro [1 ]
Nagano, Akira [2 ]
Kojima, Hironori [3 ,5 ]
Ikeda, Tomohiro [4 ]
Yokoyama, Noriomi [5 ]
Tsukamoto, Kosuke [3 ]
Noto, Kimiya [3 ]
Isomura, Naoki [3 ]
Ueda, Shinichi [3 ]
Kawashima, Hiroki [1 ]
机构
[1] Kanazawa Univ, Fac Hlth Sci, Inst Med Pharmaceut & Hlth Sci, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
[2] Okayama Univ Hosp, Div Radiol, Kita Ku, 2-5-1 Shikatacho, Okayama 7008558, Japan
[3] Kanazawa Univ Hosp, Dept Radiol Technol, 13-1 Takaramachi, Kanazawa, Ishikawa 9208641, Japan
[4] Southern Tohoku Proton Therapy Ctr, Dept Radiat Oncol, 7-115 Yatsuyamada, Koriyama, Fukushima 9638563, Japan
[5] Kanazawa Univ, Grad Sch Med Sci, Div Hlth Sci, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
基金
日本学术振兴会;
关键词
Deformable image registration; Uncertainty; Deformation vector field correctness; Radiotherapy;
D O I
10.1016/j.phro.2018.05.005
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: In adaptive radiotherapy, deformable image registration (DIR) is used to propagate delineations of tumors and organs into a new therapy plan and to calculate the accumulated total dose. Many DIR accuracy metrics have been proposed. An alternative proposed here could be a local uncertainty (LU) metric for DIR results. Materials and methods: The LU represented the uncertainty of each DIR position and was focused on deformation evaluation in uniformly-dense regions. Four cases demonstrated LU calculations: two head and neck cancer cases, a lung cancer case, and a prostate cancer case. Each underwent two CT examinations for radiotherapy planning. Results: LU maps were calculated from each DIR of the clinical cases. Reduced fat regions had LUs of 4.6 +/- 0.9 mm, 4.8 +/- 1.0 mm, and 4.5 +/- 0.7 mm, while the shrunken left parotid gland had a LU of 4.1 +/- 0.8mm and the shrunken lung tumor had a LU of 3.7 +/- 0.7 mm. The bowels in the pelvic region had a LU of 10.2 +/- 3.7 mm. LU histograms for the cases were similar and 99% of the voxels had a LU < 3 mm. Conclusions: LU is a new uncertainty metric for DIR that was demonstrated for clinical cases. It had a tolerance of < 3 mm.
引用
收藏
页码:77 / 82
页数:6
相关论文
共 50 条
  • [1] The delta index: a novel metric to assess dose accumulation uncertainty in MR-guided radiotherapy
    van den Dobbelsteen, M.
    Hackett, S.
    Verhoeff, J.
    Merckel, L.
    van Es, C.
    Snoeren, L.
    Kontaxis, C.
    Fast, M.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S700 - S702
  • [2] Composition of Deformation Vector Fields for Dose Mapping During Head and Neck Adaptive Radiotherapy
    Cazoulat, G.
    McCulloch, M.
    Bahig, H.
    Elgohari, B.
    Elhalawani, H.
    Mohamed, A.
    Fuller, C.
    Brock, K.
    MEDICAL PHYSICS, 2019, 46 (06) : E246 - E246
  • [3] Large deformation diffeomorphic metric mapping of vector fields
    Cao, Y
    Miller, MI
    Winslow, RL
    Younes, L
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (09) : 1216 - 1230
  • [4] Dose Deformation and Accumulation for Adaptive Radiotherapy in Nasopharyngeal Carcinoma
    Zhou, Lu
    Zhang, Shuxu
    Yuan, Kehong
    Wang, Linjing
    Peng, Yingying
    2015 8TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI), 2015, : 397 - 401
  • [5] Development of a multi-layer quality assurance program to evaluate the uncertainty of deformable dose accumulation in adaptive radiotherapy
    Zhong, Hualiang
    Garcia-Alvarez, Juan A.
    Kainz, Kristofer
    Tai, An
    Ahunbay, Ergun
    Erickson, Beth
    Schultz, Christopher J.
    Li, X. Allen
    MEDICAL PHYSICS, 2023, 50 (03) : 1766 - 1778
  • [6] On the Utilization of a Pseudo-Inverse Consistency Metric to Evaluate Deformable Dose Accumulation Error for MRI-Guide Adaptive Radiotherapy
    Zhong, H.
    Garcia-Alvarez, J.
    Kainz, K.
    Li, X.
    MEDICAL PHYSICS, 2022, 49 (06) : E281 - E281
  • [7] A Novel Metric to Evaluate Dose Deformation Error for Deformable Image Registration Algorithms
    Surucu, M.
    Roeske, J.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [8] Effect of deformation due to breathing on dose accumulation for liver cancer radiotherapy
    Brock, K. K.
    Moseley, J.
    Eccles, C.
    Craig, T.
    Sharpe, M. B.
    Dawson, L. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S52 - S52
  • [9] Validity of dose shift-deformation invariance assumption for dose accumulation in head & neck radiotherapy
    Van Kranen, S.
    Wolf, A.
    Van Beek, S.
    Hamming-Vrieze, O.
    Van Herk, M.
    Sonke, J. J.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S95 - S96
  • [10] Quantifying the dose accumulation uncertainty after DIR in head-and-neck radiotherapy
    Lowther, N.
    Marsh, S.
    Louwe, R.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S903 - S904