AUTOMATIC EXPOSURE CONTROL RESPONSE IN MAMMOGRAPHY

被引:0
|
作者
AKBER, SF [1 ]
机构
[1] MARSHFIELD CLIN FDN MED RES & EDUC,DEPT RADIOL,MARSHFIELD,WI 54449
关键词
MAMMOGRAPHY; PHOTOTIMER; BREAST; RADIOGRAPHIC IMAGING;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The use of automatic exposure control (AEC) in mammography systems does not perform to meet the acceptable criteria and yields poor image quality. The parameters assessed are: 1) AEC response for a fixed thickness al different kVp, 2) AEC reciprocity performance at a given kVp with varying thickness of lucite and BR-12 tissue equivalent phantom, 3) AEC time out characteristics.
引用
收藏
页码:111 / 113
页数:3
相关论文
共 50 条
  • [1] Evaluation of automatic exposure control options in digital mammography
    Zhou, Yifang
    Scott, Alexander, II
    Allahverdian, Janet
    Frankel, Steve
    [J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2014, 22 (03) : 377 - 394
  • [2] Appropriate phantom for automatic exposure control compensation testing in mammography
    Nosil, J
    MacDonald, JCF
    Situ, K
    [J]. PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 1475 - 1478
  • [3] Tailoring automatic exposure control toward constant detectability in digital mammography
    Salvagnini, Elena
    Bosmans, Hilde
    Struelens, Lara
    Marshall, Nicholas W.
    [J]. MEDICAL PHYSICS, 2015, 42 (07) : 3834 - 3847
  • [4] QUALITY-CONTROL IN MAMMOGRAPHY BASED ON AUTOMATIC ACQUISITION OF EXPOSURE PARAMETERS
    WALDERHAUG, TP
    EINARSSON, G
    KRISTINSSON, S
    MAGNUSSON, SM
    SIGFUSSON, BF
    [J]. RADIATION PROTECTION DOSIMETRY, 1995, 57 (1-4) : 199 - 201
  • [5] PERFORMANCE OF AUTOMATIC EXPOSURE CONTROLS IN MAMMOGRAPHY
    KARILA, KTK
    [J]. MEDICAL PHYSICS, 1982, 9 (06) : 898 - 903
  • [6] The use of detectability indices as a means of Automatic Exposure Control for a digital mammography system
    Salvagnini, Elena
    Bosmans, Hilde
    Monnin, Pascal
    Struelens, Lara
    Verdun, Francis
    Marshall, Nicholas W.
    [J]. MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [7] Automatic exposure control for a slot scanning full field digital mammography system
    Elbakri, DA
    Lakshminarayanan, AV
    Tesic, MM
    [J]. MEDICAL PHYSICS, 2005, 32 (09) : 2763 - 2770
  • [8] AUTOMATIC X-RAY EXPOSURE CONTROLLER FOR MAMMOGRAPHY
    ROSE, JH
    BERDAHL, CM
    [J]. RADIOLOGY, 1977, 122 (01) : 252 - 253
  • [9] ACCURATE AUTOMATIC EXPOSURE CONTROLLER FOR MAMMOGRAPHY - DESIGN AND PERFORMANCE
    FREDERICK, EE
    SQUILLANTE, MR
    CIRIGNANO, LJ
    HAHN, RW
    ENTINE, G
    [J]. RADIOLOGY, 1991, 178 (02) : 393 - 396
  • [10] Procedure for quantitatively assessing automatic exposure control in mammography: a study of the GE Senographe 600 TS
    Meeson, S
    Young, KC
    Hollaway, PB
    Wallis, MG
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (883): : 615 - 620