Computer-assisted orthopaedic fracture reduction: clinical evaluation of a second generation prototype

被引:2
|
作者
Khoury, Amal [1 ]
Beyth, Shaul [1 ]
Mosheiff, Rami [1 ]
Joskowicz, Leo [2 ]
Finkelstein, Joel [3 ]
Liebergall, Meir [1 ]
机构
[1] Hadassah Hebrew Univ Med Ctr, Dept Orthoped Surg, Jerusalem, Israel
[2] Hebrew Univ Jerusalem, Sch Engn & Comp Sci, Jerusalem, Israel
[3] Sunnybrook Hlth Sci Ctr, Dept Orthoped Surg, Toronto, ON, Canada
来源
CURRENT ORTHOPAEDIC PRACTICE | 2011年 / 22卷 / 01期
关键词
Computer aided surgery; fracture reduction; intramedullary nailing; long-bone fractures;
D O I
10.1097/BCO.0b013e3181f4a2b0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background The goal of this study was to evaluate a new second generation of computer-assisted fluoroscopic navigation software for fracture reduction (SGFR) of long-bone fractures. The new software allows simultaneous tracking of two moving bone fragments. Methods Between 2005--2007, patients with isolated, extra-articular longbone fracture of either the femur or tibia were considered for computer-assisted fluoroscopic fracture reduction surgery. The operative tasks were: (1) fracture reduction; (2) determination of the entry point, and; (3) Poller screw insertion, when needed. Fracture reduction was achieved by one of two methods: (1) fracture edges or (2) medullary canal recognition. Fracture reduction was considered successful if the guide wire was introduced through the fracture without further radiation. Results We treated 38 patients (27 men and 11 women); with 15 femoral and 23 tibial fractures, with intramedullary nail fixation. In all patients, the point of entry was navigated successfully. In four patients, the insertion of the blocking screw was planned and executed without further radiation. All fractures were successfully reduced using the SGFR system. In nine patients, we used method 1, in 22 patients method 2, and in six a combination of both. The number of fluoroscopic images was dramatically reduced to four to six images. Conclusions Fracture reduction was reliably achievable in all patients using the SGFR. A key conclusion is that only a small number of fluoroscopic images are required. Although timing was not an objective of this study, we believe that there was a noticeable reduction of intraoperative time.
引用
收藏
页码:109 / 115
页数:7
相关论文
共 50 条
  • [1] Computer-assisted Femur Fracture Reduction
    Frank, Johannes
    Gritzbach, Bernd
    Winter, Christian
    Maier, Bernd
    Marzi, Ingo
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2010, 36 (02) : 151 - 156
  • [2] Computer-assisted Femur Fracture Reduction
    Johannes Frank
    Bernd Gritzbach
    Christian Winter
    Bernd Maier
    Ingo Marzi
    European Journal of Trauma and Emergency Surgery, 2010, 36 : 151 - 156
  • [3] Advancing computer-assisted orthopaedic surgery using a hexapod device for closed diaphyseal fracture reduction
    Du, Hailong
    Hu, Lei
    Li, Changsheng
    Wang, Tianmiao
    Zhao, Lu
    Li, Yang
    Mao, Zhi
    Liu, Daohong
    Zhang, Lining
    He, Chunqing
    Zhang, Licheng
    Hou, Hongping
    Zhang, Lihai
    Tang, Peifu
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2015, 11 (03): : 348 - 359
  • [4] Computer-assisted orthopaedic surgery
    Jaramaz, Branislav
    Hafez, Mahmoud A.
    DiGioia, Anthony M., III
    PROCEEDINGS OF THE IEEE, 2006, 94 (09) : 1689 - 1695
  • [5] Computer-assisted Orthopaedic Surgery
    Hernandez, David
    Garimella, Roja
    Eltorai, Adam E. M.
    Daniels, Alan H.
    ORTHOPAEDIC SURGERY, 2017, 9 (02) : 152 - 158
  • [6] Computer-assisted evaluation - The next generation
    Palacio-Cayetano, J
    Allen, RD
    Stevens, RH
    AMERICAN BIOLOGY TEACHER, 1999, 61 (07): : 514 - 522
  • [7] Robotics and computer-assisted orthopaedic surgery
    Specht, Lawrence M.
    Koval, Kenneth J.
    Bulletin: Hospital for Joint Diseases, 2001, 60 (3-4): : 168 - 172
  • [8] COMPUTER-ASSISTED ORTHOPAEDIC SURGERY IN HORSES
    Perrin, Roland
    BULLETIN DE L ACADEMIE VETERINAIRE DE FRANCE, 2008, 161 (04): : 359 - 364
  • [9] Accuracy in Computer-Assisted Orthopaedic Surgery
    Cartiaux, O.
    Francq, B. G.
    Banse, X.
    Delloye, C.
    E-MEMOIRES DE L ACADEMIE NATIONALE DE CHIRURGIE, 2015, 14 (01): : 63 - 70
  • [10] Novel 3D hexapod computer-assisted orthopaedic surgery system for closed diaphyseal fracture reduction
    Tang, Peifu
    Hu, Lei
    Du, Hailong
    Gong, Minli
    Zhang, Lihai
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2012, 8 (01): : 17 - 24