DETERMINATIONS OF ORGAN OR TISSUE DOSES AND COLLECTIVE EFFECTIVE DOSE EQUIVALENT FROM DIAGNOSTIC-X-RAY EXAMINATIONS IN JAPAN

被引:0
|
作者
MARUYAMA, T
KUMAMOTO, Y
NODA, Y
IWAI, K
MASE, N
NISHIZAWA, K
FURUYA, Y
机构
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The frequency of diagnostic X ray examinations in Japan has been evaluated on the basis of the nationwide surveys of radiological examinations throughout the whole of Japan. For the determinations of organ or tissue doses, the technical factors for the radiological examinations were also investigated by the nationwide surveys. As an example of the results, the annual number of radiographs in 1986 totalled 497 million and the annual frequency of radiographic examinations was 141.5 million. The average number of the radiographs per examination was estimated to be about 3.5. The annual number of X ray CT examinations in 1989 was estimated to be 12 million. The resultant collective dose equivalent from X ray diagnosis including X ray CT was estimated to be about 2.4 x 10(5) person.Sv using organ or tissue doses determined with phantom measurements and the ICRP 1977 recommendation.
引用
收藏
页码:213 / 216
页数:4
相关论文
共 50 条
  • [1] ORGAN DOSES IN DIAGNOSTIC-X-RAY PROCEDURES
    JANKOWSKI, J
    [J]. HEALTH PHYSICS, 1984, 46 (01): : 229 - 234
  • [2] DOSES TO PATIENTS FROM ROUTINE DIAGNOSTIC-X-RAY EXAMINATIONS IN ENGLAND
    SHRIMPTON, PC
    WALL, BF
    JONES, DG
    FISHER, ES
    HILLIER, MC
    KENDALL, GM
    HARRISON, IRM
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1986, 59 (704): : 749 - 758
  • [3] ANNUAL PER CAPUT EFFECTIVE DOSE EQUIVALENT OF BEIJING INHABITANTS FROM DIAGNOSTIC-X-RAY PROCEDURES
    ZHENG, JZ
    [J]. HEALTH PHYSICS, 1990, 59 (06): : 939 - 940
  • [4] Organ dose determinations of X ray examinations using TL detectors for verification of computed doses
    Toivonen, M
    Aschan, C
    Rannikko, S
    Karila, K
    Savolainen, S
    [J]. RADIATION PROTECTION DOSIMETRY, 1996, 66 (1-4) : 289 - 294
  • [5] A BASIC COMPUTER-PROGRAM TO COMPUTE ORGAN DOSES FROM DIAGNOSTIC-X-RAY PROCEDURES
    BECK, TJ
    [J]. MEDICAL PHYSICS, 1983, 10 (04) : 552 - 552
  • [6] CALCULATION OF THE ESTIMATED COLLECTIVE EFFECTIVE DOSE EQUIVALENT (SE) DUE TO X-RAY DIAGNOSTIC EXAMINATIONS - ESTIMATE OF THE SE IN FINLAND
    RANNIKKO, S
    SERVOMAA, A
    ERMAKOV, I
    MASARSKII, L
    SALTUKOVA, L
    RAZUMNAYA, M
    NIKITIN, V
    [J]. HEALTH PHYSICS, 1987, 53 (01): : 31 - 36
  • [7] LEUKEMIA RISK FROM DIAGNOSTIC-X-RAY EXAMINATIONS - A CLINICAL PERSPECTIVE
    GRAY, JE
    [J]. HEALTH PHYSICS, 1993, 64 (06): : 682 - 682
  • [8] Organ Equivalent and Effective Doses from Diagnostic Radiology Procedures
    Osei, E. K.
    Govind, K.
    Charters, N.
    Barnett, R.
    [J]. MEDICAL PHYSICS, 2009, 36 (09) : 4305 - 4305
  • [9] ESTIMATIONS OF POPULATION DOSES AND RISK ESTIMATES FROM OCCUPATIONAL EXPOSURES IN JAPAN, 1978 .1. DETERMINATIONS OF ORGAN OR TISSUE DOSES AND EFFECTIVE DOSE EQUIVALENTS
    MARUYAMA, T
    NISHIZAWA, K
    NODA, Y
    TAKEDA, E
    FUKUHISA, K
    FURUYA, Y
    HASHIZUME, T
    [J]. JOURNAL OF RADIATION RESEARCH, 1981, 22 (02) : 182 - 203
  • [10] Normalized organ doses and effective doses to a reference Indian adult male in conventional medical diagnostic x-ray examinations
    Biju, K
    Nagarajan, PS
    [J]. HEALTH PHYSICS, 2006, 90 (03): : 217 - 222