EVALUATION OF PULMONARY-ARTERY ANATOMY USING MAGNETIC-RESONANCE - THE IMPORTANCE OF MULTIPLANAR AND OBLIQUE IMAGING

被引:13
|
作者
HAYES, AM
BAKER, EJ
PARSONS, J
ANJOS, R
QURESHI, SA
MAISEY, MN
TYNAN, M
机构
[1] GUYS HOSP,DEPT PEDIAT CARDIOL,LONDON SE1 9RT,ENGLAND
[2] GUYS HOSP,DEPT RADIOL,LONDON SE1 9RT,ENGLAND
关键词
MAGNETIC RESONANCE IMAGING; PULMONARY ARTERIES;
D O I
10.1007/BF00796999
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Pulmonary artery anatomy was studied in 36 patients (age range 12 days to 12.83 years, mean 2.9 years) with right ventricular outflow tract obstruction over a 3-year period using a 1.5 Tesla Magnetic Resonance system. Gated spin-echo sequences were obtained in each patient. Image planes used were straight and oblique transverse, oblique coronal, and oblique sagittal. The studies were analyzed retrospectively and comparative angiographic, surgical, and postmortem data was available in all cases. As previously noted with other imaging modalities, multiple views and oblique cuts were found to increase significantly the quality and accuracy of the information acquired. In 12 of the 15 patients who had axial and coronal imaging of both branch pulmonary arteries, the pulmonary arteries were unequivocally demonstrated to at least the first hilar branch. However, early in our experience we missed a number of branch stenoses that developed following surgical anastomoses. These mistakes were caused by inadequate or inappropriate slice acquisition. Magnetic resonance is an important technique for imaging pulmonary arteries. Careful use of the appropriate imaging planes is essential for accurate demonstration of the anatomy.
引用
收藏
页码:8 / 13
页数:6
相关论文
共 50 条
  • [1] CORRELATIVE MAGNETIC-RESONANCE IMAGING IN THE EVALUATION OF AORTIC AND PULMONARY-ARTERY ABNORMALITIES
    RISIUS, B
    ODONNELL, JK
    GEISINGER, MA
    ZELCH, MG
    GEORGE, CR
    GRAOR, RA
    MOODIE, DS
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1985, 26 (05) : P7 - P7
  • [2] MAGNETIC-RESONANCE IMAGING - EVALUATION OF PALLIATIVE SYSTEMIC PULMONARY-ARTERY SHUNTS
    JACOBSTEIN, MD
    FLETCHER, BD
    NELSON, AD
    CLAMPITT, M
    ALFIDI, RJ
    RIEMENSCHNEIDER, TA
    [J]. CIRCULATION, 1984, 70 (04) : 650 - 656
  • [3] PULMONARY-ARTERY THROMBUS DETECTION BY MAGNETIC-RESONANCE IMAGING
    SZUCS, RA
    REHR, RB
    TATUM, JL
    [J]. CHEST, 1989, 95 (01) : 232 - 234
  • [4] PULMONARY-ARTERY SLING - DIAGNOSIS BY MAGNETIC-RESONANCE IMAGING
    MALMGREN, N
    LAURIN, S
    LUNDSTROM, NR
    [J]. ACTA RADIOLOGICA, 1988, 29 (01) : 7 - 9
  • [5] MAGNETIC-RESONANCE IMAGING OF AN ANOMALOUS ORIGIN OF THE LEFT CORONARY-ARTERY FROM THE PULMONARY-ARTERY
    DOUARD, H
    BARAT, JL
    LAURENT, F
    MORA, B
    BAUDET, E
    BROUSTET, JP
    [J]. EUROPEAN HEART JOURNAL, 1988, 9 (12) : 1356 - 1360
  • [6] MAGNETIC-RESONANCE AND ECHOCARDIOGRAPHIC IMAGING OF PULMONARY-ARTERY SIZE THROUGHOUT STAGES OF FONTAN RECONSTRUCTION
    FOGEL, MA
    RAMACIOTTI, C
    HUBBARD, AM
    WEINBERG, PM
    [J]. CIRCULATION, 1992, 86 (04) : 500 - 500
  • [7] MAGNETIC-RESONANCE AND ECHOCARDIOGRAPHIC IMAGING OF PULMONARY-ARTERY SIZE THROUGHOUT STAGES OF FONTAN RECONSTRUCTION
    FOGEL, MA
    DONOFRIO, MT
    RAMACIOTTI, C
    HUBBARD, AM
    WEINBERG, PM
    [J]. CIRCULATION, 1994, 90 (06) : 2927 - 2936
  • [8] MAGNETIC-RESONANCE-IMAGING OF PULMONARY-ARTERY ANEURYSM
    SHAH, HR
    STARK, JE
    BUCKNER, CB
    [J]. SOUTHERN MEDICAL JOURNAL, 1991, 84 (08) : 1026 - 1028
  • [9] Coronary-pulmonary artery fistulae depicted by multiplanar reconstruction using magnetic resonance imaging
    Taoka, Y
    Nomura, M
    Harada, M
    Mitani, T
    Endo, J
    Kondo, Y
    Yukinaka, M
    Ito, S
    Nakaya, Y
    Nishitani, H
    [J]. JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1998, 62 (06): : 455 - 457
  • [10] MAGNETIC-RESONANCE EVALUATION OF PATENCY OF STENTED POLYTETRAFLUOROETHYLENE GRAFT CONNECTING RIGHT ATRIUM TO PULMONARY-ARTERY
    NAWA, S
    YAMADA, M
    IRIE, H
    TERAMOTO, S
    [J]. CHEST, 1988, 94 (05) : 1105 - 1107