ARTERIOVENOUS DIFFERENCES IN PCO2 AND CARDIAC-OUTPUT DURING CPR IN THE DOG

被引:13
|
作者
SATO, S
OKUBO, N
SATSUMAE, T
KUMAGAI, M
YAMAMOTO, S
NAKAYAMA, H
TAGUCHI, N
机构
[1] Department of Anesthesiology, Institute of Clinical Medicine, University of Tsukuba, Tsukuba-shi, Ibaraki
关键词
CPR; ARTERIOVENOUS DIFFERENCES (AVD) OF CO2; END-TIDAL CO2; CARDIAC OUTPUT;
D O I
10.1016/0300-9572(94)90039-6
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Using 14 mongrel dogs, we investigated the correlation between arteriovenous differences of PCO2 (AVD-CO2) and cardiac output (CO) during CPR. Ventricular fibrillation was induced by an electrical current and the respirator was stopped for 5 min. Cardiopulmonary resuscitation (CPR) was performed during the next 10 min and CO was measured with simultaneous arterial and venous blood gas analysis. CO was measured 26 times during CPR. The animals were divided into two groups according to the values of CO during CPR: low-CO group (CO < 0.3 1/min) and high-CO group (CO greater-than-or-equal-to 0.3 l/min). AVD-CO2 in the low CO group was 39.8 +/- 5.7 mmHg and that of the high group was 27.4 +/- 14.8 mmHg (mean +/- S.D., P < 0.05). In conclusion, AVD-CO2 showed an inverse result with the degree of CO during CPR.
引用
收藏
页码:255 / 259
页数:5
相关论文
共 50 条
  • [1] ARTERIAL PCO2 REFLECTS CARDIAC-OUTPUT AND PROGNOSTICATES RESUSCITABILITY DURING CPR
    GAZMURI, R
    WEIL, MH
    VONPLANTA, M
    BISERA, J
    RACKOW, EC
    CLINICAL RESEARCH, 1987, 35 (06): : A875 - A875
  • [2] EFFECT OF ANALYZER ON DETERMINATION OF MIXED VENOUS PCO2 AND CARDIAC-OUTPUT DURING EXERCISE
    HORNBY, L
    COATES, AL
    LANDS, LC
    JOURNAL OF APPLIED PHYSIOLOGY, 1995, 79 (03) : 1032 - 1038
  • [3] ROLE OF CARDIAC-OUTPUT FOR EFFECT OF NATURAL PCO2 OSCILLATIONS ON RESPIRATION
    PLAASLINK, A
    LUTTMANN, A
    MUELLER, J
    MUCKENHOFF, K
    LOESCHCKE, HH
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1978, : R40 - R40
  • [4] CARDIAC-OUTPUT DURING CPR - A COMPARISON OF 2 METHODS
    SILVER, DI
    MURPHY, RJ
    BABBS, CF
    GEDDES, LA
    CRITICAL CARE MEDICINE, 1981, 9 (05) : 419 - 420
  • [5] THE INFLUENCE OF CHANGES IN CARDIAC-OUTPUT ON ARTERIAL AND MIXED VENOUS PH AND PCO2
    HOOGEVEEN, YL
    ZOCK, JP
    RISPENS, P
    ZIJLSTRA, WG
    EXPERIENTIA, 1986, 42 (11-12): : 1305 - 1305
  • [6] CAN CHANGES IN END-TIDAL PCO2 MEASURE CHANGES IN CARDIAC-OUTPUT
    ISSERLES, SA
    BREEN, PH
    ANESTHESIA AND ANALGESIA, 1991, 73 (06): : 808 - 814
  • [7] NON-INVASIVE METHOD FOR MEASURING MIXED VENOUS PCO2 AND CARDIAC-OUTPUT
    HOFFSTEIN, V
    REBUCK, AS
    FEDERATION PROCEEDINGS, 1979, 38 (03) : 890 - 890
  • [8] VENOUS PCO2 AND CARDIAC-OUTPUT OBTAINED FROM REBREATHING CURVES - BY EXTRAPOLATION OR BY A PLATEAU METHOD
    WISE, ME
    DEFARES, JG
    CLINICAL SCIENCE, 1972, 43 (02) : 303 - &
  • [9] INFLUENCE OF ESTIMATES OF ARTERIAL PCO2 ON FICK CO2 VALUES OF CARDIAC-OUTPUT ON EXERCISE
    RAIMONDI, GA
    PUY, RJM
    RAIMONDI, AC
    MANRIQUE, JL
    MARCHISSIO, ML
    ACTA PHYSIOLOGICA LATINOAMERICANA, 1974, 24 (03) : 258 - 264
  • [10] ARTERIAL-EXPIRED PCO2 DIFFERENCES IN THE DOG DURING ACUTE HYPERCAPNIA