Resistance of Concrete Masonry Walls with Membrane Catcher Systems Subjected to Blast Loading

被引:5
|
作者
Moradi, Lee G. [1 ]
Dinan, Robert J. [2 ]
Bewick, Bryan T. [3 ]
Davidson, James S. [4 ]
机构
[1] Univ Alabama Birmingham, Ctr Biophys Sci & Engn, Birmingham, AL 35294 USA
[2] US Air Force, Civil Engn Support Agcy, Res Lab, Tyndall AFB, FL 32403 USA
[3] US Air Force, Res Lab, Airbase Technol Div, Tyndall AFB, FL 32403 USA
[4] Auburn Univ, Dept Civil Engn, Harbert Engn Ctr 238, Auburn, AL 36849 USA
关键词
D O I
10.1260/2041-4196.2.1.83
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper describes a methodology for analyzing the impulse pressure response of unreinforced concrete masonry walls that have been retrofitted with membranes that are not bonded to the masonry (catcher systems). Membrane catcher systems can be used to protect building occupants from secondary debris resulting from blast pressure, and the effectiveness of systems comprised of polymers, composites, geotextiles, and thin steel and aluminum sheets has been researched extensively over the past fifteen years. The methodology presented herein is based upon the large displacement response of the unreinforced masonry wall, with and without compression membrane arching, and the subsequent tension membrane resistance of the catcher system. The necessary equations are developed in the form of nonlinear resistance functions, which are then used in single-degree-of-freedom analyses to develop dynamic response predictions. The applicability of the approach is substantiated through comparison to full-scale blast test results, and demonstrations involving disparate materials and loading are made.
引用
收藏
页码:83 / 102
页数:20
相关论文
共 50 条
  • [1] Fragment response of unreinforced concrete masonry walls subjected to blast loading
    Hatfield, John E.
    Pezzola, Genevieve L.
    Walker, Robert E.
    Stephens, Catherine S.
    Davidson, James S.
    INTERNATIONAL JOURNAL OF PROTECTIVE STRUCTURES, 2022, 13 (02) : 161 - 181
  • [2] Fragment velocity response of grouted and unreinforced concrete masonry walls subjected to blast loading
    Hatfield, John E.
    Pezzola, Genevieve L.
    Walker, Robert E.
    Stephens, Catherine S.
    Davidson, James S.
    INTERNATIONAL JOURNAL OF PROTECTIVE STRUCTURES, 2025, 16 (01) : 42 - 60
  • [3] Response of Arching Unreinforced Concrete Masonry Walls to Blast Loading
    Abou-Zeid, Badr M.
    El-Dakhakhni, Wael W.
    Razaqpur, A. Ghani
    Foo, S.
    JOURNAL OF STRUCTURAL ENGINEERING, 2011, 137 (10) : 1205 - 1214
  • [4] Behaviour of retrofitted masonry walls subjected to blast loading: Damage assessment
    Chiquito, M.
    Lopez, L. M.
    Castedo, R.
    Perez-Caldentey, A.
    Santos, A. P.
    ENGINEERING STRUCTURES, 2019, 201
  • [5] Expedient FE analysis of concrete masonry walls subjected to blast loads
    Eamon, CD
    Baylot, JT
    O'Daniel, JL
    COMPUTATIONAL FLUID AND SOLID MECHANICS 2003, VOLS 1 AND 2, PROCEEDINGS, 2003, : 242 - 245
  • [6] Evaluation of masonry walls subjected to blast loading based on material modelling approach
    Weli, Sardasht S.
    Abbood, Imad Shakir
    Al-Rukaibawi, Layth S.
    Hamid, Fkrat L.
    MATERIALS TODAY-PROCEEDINGS, 2022, 49 : 3687 - 3695
  • [7] Failure mechanisms of polymer-reinforced concrete masonry walls subjected to blast
    Davidson, JS
    Fisher, JW
    Hammons, MI
    Porter, JR
    Dinan, RJ
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2005, 131 (08): : 1194 - 1205
  • [8] Simulation of Retrofitted Unreinforced Concrete Masonry Unit Walls under Blast Loading
    Aghdamy, Sanam
    Wu, Chengqing
    Griffith, Michael
    INTERNATIONAL JOURNAL OF PROTECTIVE STRUCTURES, 2013, 4 (01) : 21 - 44
  • [9] Blast Resistance of Fully Grouted Reinforced Concrete Masonry Veneer Walls
    Browning, Robert S.
    Dinan, Robert J.
    Davidson, James S.
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2014, 28 (02) : 228 - 241
  • [10] PRESTRESSED CONCRETE MASONRY WALLS SUBJECTED TO UNIFORM OUT-OF-PLANE LOADING