RASTI MEASUREMENTS IN MOSQUES IN AMMAN, JORDAN

被引:12
|
作者
HAMMAND, RNS
机构
[1] Architectural Department, Faculty of Engineering and Technology, University of Jordan, Amman
关键词
D O I
10.1016/0003-682X(90)90082-6
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Field measurements in 30 mosques in Amman, Jordan are reported; the field measurements include RASTI, reverberation time, background noise level EDT and signal to noise ratio. RASTI values range between 0·39 and 0·59 where the articulation index ranges between poor and fair. There is not a single mosque in which the articulation index is good or excellent; despite the fact that these mosques are costly and their spiritual and functional aspects have received special attention, the reverberation time is, in general high and, in one mosque it was around 27 s at low frequency. In the Jordan University Mosque the reverberation time varies between 10 and 4 s. The poor acoustical performance of these mosques is mainly the result of little treatment inside and high background noise due to poor insulation of the building envelope against external noise. © 1990.
引用
收藏
页码:335 / 345
页数:11