USE OF QUALITY-CONTROL STANDARDS IN CLINICAL FLOW-CYTOMETRY

被引:13
|
作者
AGRAWAL, YP
MAHLAMAKI, EK
PENTTILA, IM
机构
[1] Department of Clinical Chemistry, Kuopio University Central Hospital, Kuopio
关键词
QUALITY CONTROL; FLOW CYTOMETRY;
D O I
10.3109/07853899109148036
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Flow cytometry is important in the clinical laboratory, especially in hematology and cancer diagnosis. With newer applications being continuously developed clinicians who will use the results and laboratory staff who produce them should be aware of the instrumental quality control procedures required. This will allow evaluation of the reliability as well as the comparison of results between different laboratories. While information about sample preparation as well as staining procedures is easily available, information about instrumental quality control procedures is less so. Various standards and controls are available commercially and their correct choice and usage requires an understanding of the methodology of instrumental quality control. Methods to evaluate the precision, sensitivity and accuracy of measurements are discussed. Most laboratories report immunophenotyping data as the percentage of antibody positive cells and make no attempt to quantitate the amount of antibody binding per cell. Methods for quantitating the number of bound antibody molecules per cell along with a simple technique to compare results between laboratories are discussed. These techniques should encourage laboratory staff and clinicians to standardise methodology and to exchange patient data between laboratories.
引用
收藏
页码:127 / 133
页数:7
相关论文
共 50 条
  • [1] QUALITY-CONTROL IN CLINICAL FLOW-CYTOMETRY
    HARVATH, L
    PATHOLOGY AND IMMUNOPATHOLOGY RESEARCH, 1988, 7 (05): : 338 - 344
  • [2] ESTABLISHMENT OF QUALITY-CONTROL PROCEDURES IN CLINICAL FLOW-CYTOMETRY
    MUIRHEAD, KA
    ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1993, 677 : 1 - 20
  • [3] QUALITY-CONTROL AND QUALITY ASSURANCE IN FLOW-CYTOMETRY
    MAYALL, BH
    ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1993, 677 : 78 - 81
  • [4] FLUORESCENCE INTENSITY AS A QUALITY-CONTROL PARAMETER IN CLINICAL FLOW-CYTOMETRY
    CALDWELL, CW
    MAGGI, J
    HENRY, LB
    TAYLOR, HM
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1987, 88 (04) : 447 - 456
  • [5] TIME, A QUALITY-CONTROL PARAMETER IN FLOW-CYTOMETRY
    WATSON, JV
    CYTOMETRY, 1987, 8 (06): : 646 - 649
  • [6] QUALITY-CONTROL ISSUES IN DNA CONTENT FLOW-CYTOMETRY
    BAUER, KD
    ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1993, 677 : 59 - 77
  • [7] DEVELOPMENT OF CLINICAL STANDARDS FOR FLOW-CYTOMETRY
    SCHWARTZ, A
    FERNANDEZREPOLLET, E
    ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1993, 677 : 28 - 39
  • [8] RESULTS OF THE FLOW-CYTOMETRY ACTG QUALITY-CONTROL PROGRAM - ANALYSIS AND FINDINGS
    PAXTON, H
    KIDD, P
    LANDAY, A
    GIORGI, J
    FLOMENBERG, N
    WALKER, E
    VALENTINE, F
    FAHEY, J
    GELMAN, R
    CLINICAL IMMUNOLOGY AND IMMUNOPATHOLOGY, 1989, 52 (01): : 68 - 84
  • [9] QUALITY-CONTROL STUDY OF THE ITALIAN GROUP OF CYTOMETRY ON FLOW-CYTOMETRY CELLULAR DNA CONTENT MEASUREMENTS
    DANESI, DT
    SPANO, M
    ALTAVISTA, P
    CYTOMETRY, 1993, 14 (05): : 576 - 583
  • [10] QUALITY-CONTROL FOR EVALUATION OF THE S-PHASE FRACTION BY FLOW-CYTOMETRY - A MULTICENTRIC STUDY
    SILVESTRINI, R
    LUISI, A
    DAIDONE, MG
    COSTA, A
    VALENTINIS, B
    ZUPI, G
    DAGNANO, I
    GEIDO, E
    GIARETTI, W
    PEPE, S
    RUGGIERO, A
    RUSSO, A
    BAZAN, V
    FACCHINI, A
    LALLI, E
    MAZZINI, G
    UNGARI, S
    RIBA, S
    CYTOMETRY, 1994, 18 (01): : 11 - 16