ANALYSIS OF CHEMICAL CARCINOGENS .25. DETERMINATION OF ACRIDINE, BENZ[C]ACRIDINE AND DIBENZ[A,H]ACRIDINE BY FAST-SCAN DIFFERENTIAL-PULSE VOLTAMMETRY AND ADSORPTIVE STRIPPING VOLTAMMETRY

被引:5
|
作者
BAREK, J
MATEJKA, J
ZIMA, J
机构
关键词
D O I
10.1135/cccc19940294
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The behaviour of the title compounds in fast scan differential pulse voltammetry and adsorptive stripping voltammetry was studied and the optimum conditions were found for their determination by FS DPV over the concentration region of (2 - 100) . 10(-7) mol l-1 and by AdSV over the concentration regions of (2 - 10) . 10(-8) mol l-1 for acridine and dibenz[a,h]acridine and (2 - 100) . 10(-9) mol l-1 for benz[c]acridine. Practical applicability of the methods to the monitoring of the chemical efficiency of destruction of the carcinogens with potassium permanganate was testcd.
引用
收藏
页码:294 / 308
页数:15
相关论文
共 1 条