Using a slit lamp-mounted digital high-speed camera for dynamic observation of phakic lenses during eye movements: a pilot study

被引:1
|
作者
Leitritz, Martin Alexander [1 ]
Ziemssen, Focke [1 ]
Bartz-Schmidt, Karl Ulrich [1 ]
Voykov, Bogomil [1 ]
机构
[1] Eberhard Karls Univ Tubingen, Univ Eye Hosp, Ctr Ophthalmol, Schleichstr 12, D-72076 Tubingen, Baden Wurttembe, Germany
来源
CLINICAL OPHTHALMOLOGY | 2014年 / 8卷
关键词
intraocular lens; high-speed camera; phakic lens;
D O I
10.2147/OPTH.S64722
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate a digital high-speed camera combined with digital morphometry software for dynamic measurements of phakic intraocular lens movements to observe kinetic influences, particularly in fast direction changes and at lateral end points. Materials and methods: A high-speed camera taking 300 frames per second observed movements of eight iris-claw intraocular lenses and two angle-supported intraocular lenses. Standardized saccades were performed by the patients to trigger mass inertia with lens position changes. Freeze images with maximum deviation were used for digital software-based morphometry analysis with ImageJ. Results: Two eyes from each of five patients (median age 32 years, range 28-45 years) without findings other than refractive errors were included. The high-speed images showed sufficient usability for further morphometric processing. In the primary eye position, the median decentrations downward and in a lateral direction were -0.32 mm (range -0.69 to 0.024) and 0.175 mm (range -0.37 to 0.45), respectively. Despite the small sample size of asymptomatic patients, we found a considerable amount of lens dislocation. The median distance amplitude during eye movements was 0.158 mm (range 0.02-0.84). There was a slight positive correlation (r=0.39, P<0.001) between the grade of deviation in the primary position and the distance increase triggered by movements. Conclusion: With the use of a slit lamp-mounted high-speed camera system and morphometry software, observation and objective measurements of iris-claw intraocular lenses and angle-supported intraocular lenses movements seem to be possible. Slight decentration in the primary position might be an indicator of increased lens mobility during kinetic stress during eye movements. Long-term assessment by high-speed analysis with higher case numbers has to clarify the relationship between progressing motility and endothelial cell damage.
引用
收藏
页码:1361 / 1367
页数:7
相关论文
共 14 条
  • [1] The observation of crack tip vicinity by high-speed camera for study of dynamic fracture toughness
    Ichinose, K
    Moriwaki, F
    Gomi, K
    SMART MATERIALS II, 2002, 4934 : 287 - 294
  • [2] Investigation of droplets released during digestive endoscopy using a high-speed camera (with video): a pilot study
    Dong Seok Lee
    Ji Bong Jeong
    Ji Won Kim
    Kook Lae Lee
    Byeong Gwan Kim
    Su Hwan Kim
    Hyoun Woo Kang
    Surgical Endoscopy, 2021, 35 : 5392 - 5396
  • [3] Investigation of droplets released during digestive endoscopy using a high-speed camera (with video): a pilot study
    Lee, Dong Seok
    Jeong, Ji Bong
    Kim, Ji Won
    Lee, Kook Lae
    Kim, Byeong Gwan
    Kim, Su Hwan
    Kang, Hyoun Woo
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2021, 35 (09): : 5392 - 5396
  • [4] Dynamic micro aspects of facial movements in elicited and posed expressions using high-speed camera
    Morishima, S
    Yotsukura, T
    Yamada, H
    Uchida, H
    Tetsutani, N
    Akamatsu, S
    ROBOT AND HUMAN COMMUNICATION, PROCEEDINGS, 2001, : 371 - 376
  • [5] Three-dimensional analysis of eye movements using four times high-speed video camera
    Yagi, T
    Koizumi, Y
    Aoyagi, M
    Kimura, M
    Sugizaki, K
    AURIS NASUS LARYNX, 2005, 32 (02) : 107 - 112
  • [6] Study of solder jet bumping process using high-speed digital camera
    Wu, Cheng-Han
    Hwang, Weng-Sing
    MATERIALS SCIENCE IN SEMICONDUCTOR PROCESSING, 2015, 31 : 38 - 43
  • [7] STUDY OF LOADING RATE EFFECT ON COMPOSITES USING A HIGH-SPEED DIGITAL CAMERA
    HSU, TY
    LIU, BC
    CHIANG, FP
    ANASTASI, R
    PROCEEDINGS OF THE 1989 SEM SPRING CONFERENCE ON EXPERIMENTAL MECHANICS, 1989, : 885 - 886
  • [8] Dynamic observation of crack generation during wheel scribing from lateral and back sides using a high-speed camera
    Imai, Kentaro
    Saito, Masahiro
    Matsusaka, Souta
    Matsumoto, Yuichiro
    Hidai, Hirofumi
    Chiba, Akira
    Morita, Noboru
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2019, 60 : 421 - 427
  • [9] Observation of eardrum movements during quasi-static pressure changes by high-speed digital imaging
    Vorwerk, U
    Steinicke, G
    Begall, K
    AUDIOLOGY AND NEURO-OTOLOGY, 1999, 4 (3-4) : 150 - 155
  • [10] OBSERVATION OF PLASMA BEHAVIOR DURING THE ECRH INJECTION BY USING A HIGH-SPEED CAMERA IN GAMMA 10
    Kigure, S.
    Nakashima, Y.
    Nishino, N.
    Hosoi, K.
    Ichimura, K.
    Takeda, H.
    Kobayashi, S.
    Mizuuchi, T.
    Ueda, H.
    Takahashi, S.
    Yoshikawa, M.
    Kohagura, J.
    Minami, R.
    Kariya, T.
    Sakamoto, M.
    Ichimura, M.
    Imai, T.
    FUSION SCIENCE AND TECHNOLOGY, 2013, 63 (1T) : 241 - 243